PS6000-MM01-EN_00

Environmental Specifications

NOTE:
  • When using any of the options for this product, check the specifications for special conditions or cautions that may apply to this product.

  • For Wall/ Flat/ Book (Top/Side) mounting and Panel (Landscape/Portrait) mounting, refer to Installation and Wiring.

Box Module (Without HDD)

Physical environment
Ambient air temperature Advanced Box Wall/Book (Side) mounting: 0...55 °C (32...131 °F) with/without FAN kit
Flat/Book (Top) mounting: 0...50 °C (32...122 °F) with/without FAN kit
Standard Box Wall/Book (Side) mounting: 0...55 °C (32...131 °F)
Flat/Book (Top) mounting: 0...50 °C (32...122 °F)
Storage temperature -30...70 °C (-22...158 °F)
Ambient air and storage humidity 10...90% RH (non condensing, wet bulb temperature 39 °C [102.2 °F] or less)
Dust 0.1 mg/m3 (10-7 oz/ft3) or less (non-conductive levels)
Pollution degree For use in Pollution Degree 2 environment
Corrosive gases Free of corrosive gases
Atmospheric pressure (operating altitude) 800...1,114 hPa (2,000 m [6,561 ft] or lower)
Mechanical environment
Vibration resistance IEC/EN 61131-2 compliant
5...9 Hz Single amplitude 3.5 mm (0.14 in)
9...150 Hz Fixed acceleration: 9.8 m/s2
X, Y, Z directions for 10 cycles (approximately 100 minutes)
Shock resistance IEC/EN 61131-2 compliant
147 m/s2, X, Y, Z directions for 3 times
Electrical environment
Electrical fast transient/burst immunity IEC 61000-4-4
2 kV: Power port
1 kV: Signal ports
Electrostatic discharge immunity Contact discharge method: 6 kV
Air discharge method: 8 kV
(IEC/EN 61000-4-2 Level 3)

Box Module (With HDD)

Physical environment
Ambient air temperature Advanced Box Wall/Book (Side) mounting: 0...45 °C (32...113 °F) with FAN kit*1
Flat/Book (Top) mounting: 0...45 °C (32...113 °F) with FAN kit*1
Standard Box Wall/Book (Side) mounting: 0...40 °C (32...104 °F)
Flat/Book (Top) mounting: 0...40 °C (32...104 °F)
Storage temperature -30...70 °C (-22...158 °F)
Ambient air and storage humidity 10...90% RH (non condensing, wet bulb temperature 39 °C [102.2 °F] or less)
Dust 0.1 mg/m3 (10-7 oz/ft3) or less (non-conductive levels)
Pollution degree For use in Pollution Degree 2 environment
Corrosive gases Free of corrosive gases
Atmospheric pressure (operating altitude) 800...1,114 hPa (2,000 m [6,561 ft] or lower)
Mechanical environment
Vibration resistance IEC/EN 61131-2 compliant
5...9 Hz Single amplitude 3.5 mm (0.14 in)
9...150 Hz Fixed acceleration: 4.9 m/s2
X, Y, Z directions for 10 cycles (approximately 100 minutes)
NOTE: In an environment with vibrations, the read/write speed on the HDD may decrease.
Shock resistance IEC/EN 61131-2 compliant
147 m/s2, X, Y, Z directions for 3 times
Electrical environment
Electrical fast transient/burst immunity IEC 61000-4-4
2 kV: Power port
1 kV: Signal ports
Electrostatic discharge immunity Contact discharge method: 6 kV
Air discharge method: 8 kV
(IEC/EN 61000-4-2 Level 3)

*1 The FAN kit is required when using this product with HDD installed.

Panel Type (Without HDD)

Physical environment
Ambient air temperature Advanced Model Panel (Landscape) mounting: 0...55 °C (32...131 °F) with/without FAN kit
(for 19” Wide, 0...50 °C (32...122 °F) with/without FAN kit)
Panel (Portrait) mounting: 0...50 °C (32...122 °F) with/without FAN kit
Standard Model Panel (Landscape) mounting: 0...55 °C (32...131 °F)
(for 19” Wide, 0...50 °C (32...122 °F))
Panel (Portrait) mounting: 0...50 °C (32...122 °F)
Storage temperature -20...60 °C (-4...140 °F)
Ambient air and storage humidity 10...90% RH (non condensing, wet bulb temperature 39 °C [102.2 °F] or less)
Dust 0.1 mg/m3 (10-7 oz/ft3) or less (non-conductive levels)
Pollution degree For use in Pollution Degree 2 environment
Corrosive gases Free of corrosive gases
Atmospheric pressure (operating altitude) 800...1,114 hPa (2,000 m [6,561 ft] or lower)
Mechanical environment
Vibration resistance IEC/EN 61131-2 compliant
5...9 Hz Single amplitude 3.5 mm (0.14 in)
9...150 Hz Fixed acceleration: 9.8 m/s2
X, Y, Z directions for 10 cycles (approximately 100 minutes)
Shock resistance IEC/EN 61131-2 compliant
147 m/s2, X, Y, Z directions for 3 times
Electrical environment
Electrical fast transient/burst immunity IEC 61000-4-4
2 kV: Power port
1 kV: Signal ports
Electrostatic discharge immunity Contact discharge method: 6 kV
Air discharge method: 8 kV
(IEC/EN 61000-4-2 Level 3)

Panel Type (With HDD)

Physical environment
Ambient air temperature Advanced Model Panel (Landscape) mounting: 0...45 °C (32...113 °F) with FAN kit*1
Panel (Portrait) mounting: 0...45 °C (32...113 °F) with FAN kit*1
Standard Model Panel (Landscape) mounting: 0...40 °C (32...104 °F)
Panel (Portrait) mounting: 0...40 °C (32...104 °F)
Storage temperature -20...60 °C (-4...140 °F)
Ambient air and storage humidity 10...90% RH (non condensing, wet bulb temperature 39 °C [102.2 °F] or less)
Dust 0.1 mg/m3 (10-7 oz/ft3) or less (non-conductive levels)
Pollution degree For use in Pollution Degree 2 environment
Corrosive gases Free of corrosive gases
Atmospheric pressure (operating altitude) 800...1,114 hPa (2,000 m [6,561 ft] or lower)
Mechanical environment
Vibration resistance IEC/EN 61131-2 compliant
5...9 Hz Single amplitude 3.5 mm (0.14 in)
9...150 Hz Fixed acceleration: 4.9 m/s2
X, Y, Z directions for 10 cycles (approximately 100 minutes)
NOTE: In an environment with vibrations, the read/write speed on the HDD may decrease.
Shock resistance IEC/EN 61131-2 compliant
147 m/s2, X, Y, Z directions for 3 times
Electrical environment
Electrical fast transient/burst immunity IEC 61000-4-4
2 kV: Power port
1 kV: Signal ports
Electrostatic discharge immunity Contact discharge method: 6 kV
Air discharge method: 8 kV
(IEC/EN 61000-4-2 Level 3)

*1 The FAN kit is required when using this product with HDD installed.

Air Quality Requirements

Do not operate or store the product where chemicals evaporate, or where chemicals are present in the air:

  • Corrosive chemicals: Acids, alkalines, liquids containing salt.

  • Flammable chemicals: Organic solvents.

CAUTION
INOPERATIVE EQUIPMENT
Do not allow water, liquids, metal, and wiring fragments to enter the panel case.
Failure to follow these instructions can result in injury or equipment damage.

Search Results (0)

Close