Box Module LED Indications
Power LED
| Color | State | Description |
|---|---|---|
| Green | ON | S0 (in operation) |
| Orange | ON | S3 |
| Flashing | System is starting up. | |
| Red | ON | S4, S4 (hybrid shutdown)*1, S5 |
| - | OFF | G3 (power is off) |
*1 S4 (hybrid shutdown) is S5 when Windows® fast startup is enabled
Wake-up Events
The following is a table showing the statuses that are set to the normal startup (S0) state when each action is executed.
| ACPI state | Power state | Power up | Power button is ON | Wake on LAN | Touch input | USB equipment*1 |
|---|---|---|---|---|---|---|
| S3 | Sleep | – | ✓ | ✓ | ✓ | ✓ |
| S4 | Hibernate | – | ✓ | ✓ | – | – |
| S4 (hybrid shutdown) | Hibernate | – | ✓ | – | – | – |
| S5 | Soft off | – | ✓ | ✓ | – | – |
| G3 | Mechanical off | ✓ | – | – | – | – |
*1 Limited to USB devices that support the remote wake-up function.
Storage Access LED
| Color | State | Description |
|---|---|---|
| Green | ON | Storage is being accessed. |
| - | OFF | Storage is not accessed. |