ST6000-MM01-EN_04

Structural Specifications

ST-6•00WA

 

ST-6200WA

ST-6400WA

ST-6500WA

Grounding

Functional grounding: Grounding resistance of 100 Ω or less, 2 mm2 (AWG 14) or thicker wire, or your country's applicable standard.

Cooling method

Natural air circulation

Structure*1

IP65F, UL 50/50E, Type 1, Type 4X (indoor use only), Type 13 (on the front panel when properly installed in an enclosure)

External dimensions (W x H x D)

134.5 x 108.5 x 43 mm

(5.3 x 4.27 x 1.69 in)

208 x 153 x 45 mm

(8.19 x 6.02 x 1.77 in)

273 x 203 x 47 mm

(10.75 x 7.99 x 1.85 in)

Panel cut dimensions (W x H)

118.5 x 92.5 mm

(4.67 x 3.64 in)*2

Panel thickness area:

1.6...5 mm
(0.06...0.2 in)*3

When using spring clips:

Position 1: 1.5...4 mm (0.06...0.16 in)

Position 2: 4...6 mm (0.16...0.24 in)

190 x 135 mm

(7.48 x 5.31 in)*2

Panel thickness area:

1.6...5 mm
(0.06...0.2 in)*3

255 x 185 mm

(10.04 x 7.28 in)*2

Panel thickness area:

1.6...5 mm
(0.06...0.2 in)*3

Weight

0.4 kg (0.88 lb) or less

0.8 kg (1.76 lb) or less

1.3 kg (2.87 lb) or less

 

ST-6600WA

ST-6700WA

Grounding

Functional grounding: Grounding resistance of 100 Ω or less, 2 mm2 (AWG 14) or thicker wire, or your country's applicable standard.

Cooling method

Natural air circulation

Structure*1

IP65F, UL 50/50E, Type 1, Type 4X (indoor use only), Type 13 (on the front panel when properly installed in an enclosure)

External dimensions (W x H x D)

313 x 235 x 50 mm

(12.32 x 9.25 x 1.97 in)

412 x 268 x 50 mm

(16.22 x 10.55 x 1.97 in)

Panel cut dimensions (W x H)

295 x 217 mm

(11.61 x 8.54 in)*2

Panel thickness area:

1.6...5 mm (0.06...0.2 in)*3

394 x 250 mm

(15.51 x 9.84 in)*2

Panel thickness area:

1.6...5 mm (0.06...0.2 in)*3

Weight

1.8 kg (3.97 lb) or less

2.7 kg (5.95 lb) or less

ST-6•00TA

 

ST-6300TA

ST-6500TA

Grounding

Functional grounding: Grounding resistance of 100 Ω or less, 2 mm2 (AWG 14) or thicker wire, or your country's applicable standard.

Cooling method

Natural air circulation

Structure*1

IP65F, UL 50/50E, Type 1, Type 4X (indoor use only), Type 12 and Type 13 (on the front panel when properly installed in an enclosure)

External dimensions (W x H x D)

169.5 x 137 x 58 mm

(6.67 x 5.39 x 2.28 in)

315 x 241 x 55.3 mm

(12.4 x 9.49 x 2.18 in)

Panel cut dimensions (W x H)

156 x 123.5 mm

(6.14 x 4.86 in)

Panel thickness area:

1.6...5 mm (0.06...0.2 in)*3

301.5 x 227.5 mm

(11.87 x 8.96 in)

Panel thickness area:

1.6...5 mm (0.06...0.2 in)*3

Weight

0.8 kg (1.76 lb) or less

1.8 kg (3.97 lb) or less

*1 The front face of this product, installed in a solid panel, has been tested using conditions equivalent to the standards shown in the specification. Even though this product's level of resistance is equivalent to these standards, oils that should have no effect on this product can possibly harm this product. This can occur in areas where either vaporized oils are present, or where low viscosity cutting oils are allowed to adhere to this product for long periods of time. If this product's front face protection sheet or cover glass peels off, these conditions can lead to the ingress of oil into this product and separate protection measures are suggested. Also, if non-approved oils are present, they may cause deformation or corrosion of the front panel's cover. Therefore, prior to installing this product, be sure to confirm the type of conditions that will be present in this product's operating environment.

If the installation gasket is used for a long period of time, or if this product and its gasket are removed from the panel, the original level of protection cannot be kept. To maintain the original protection level, be sure to replace the installation gasket regularly.

*2 For dimensional tolerance, everything +1/-0 mm (+0.04/-0 in) and R in angle are below R3 (R0.12 in).

*3 Even if the installation wall thickness is within the recommended range for the Panel Cut Dimensions, depending on the wall's material, size, and installation location of this product and other devices, the installation wall could warp. To prevent warping, the installation surface may need to be strengthened.

NOTICE
EQUIPMENT DAMAGE
  • Ensure this product is not in permanent and direct contact with oils.
  • Do not press on the display of this product with excessive force or with a hard object.
  • Do not press on the touch panel with a pointed object, such as the tip of a mechanical pencil or a screwdriver.
  • Do not expose the device to direct sunlight.
Failure to follow these instructions can result in equipment damage.
NOTICE
STORAGE AND OPERATION OUTSIDE OF SPECIFICATIONS
  • Store the panel in areas where temperatures are within the product’s specifications.
  • Do not restrict or block this panel’s ventilation slots.
Failure to follow these instructions can result in equipment damage.
NOTICE
GASKET AGING
  • Inspect the gasket periodically as required by your operating environment.
  • Change the gasket at least once a year, or as soon as scratches or dirt become visible.
Failure to follow these instructions can result in equipment damage.

Search Results (0)

Close