PS6000-MM01-EN_01

RAID Setup

NOTE:
  • In case of data corruption, we recommend preparing recovery media.

  • For information on working with Intel® Rapid Storage Technology, refer to the application online help.

  • If you configure RAID with M.2 SSD 128 GB and the M.2 SSD 128 GB needs to be replaced, replace it with the same type, M.2 SSD 128 GB. If Standard Endurance was used before, use Standard Endurance; if High Endurance was used before, use High Endurance.

  1. Turn on the product.
  2. While the boot screen is displayed, press either the [DEL] or [ESC] key.
  3. Enter the password (default password: Pw#12345).
  4. The BIOS screen is displayed.
  5. From the Advanced tab, select SATA Configuration.
  6. Select SATA Mode > RAID.
  7. Press the [F4] key.
  8. Select Yes in the Save & Exit Setup dialog box.
  9. The product is restarted.
  10. Start up Intel® Rapid Storage Technology.
  11. Select Create a custom volume.
  12. The following screen is displayed. Follow the instructions to configure RAID.
  13. The following screen displays, as the data is still being migrated. Select OK and check the progress shown on the screen.

Search Results (0)