Box Module (Without HDD)
Physical environment | ||
Ambient air temperature (T-Code: T4) | Advanced Box | Wall/Book (Side) mounting: 0...55 °C (32...131 °F) with/without FAN kit |
Flat/Book (Top) mounting: 0...50 °C (32...122 °F) with/without FAN kit | ||
Standard Box | Wall/Book (Side) mounting: 0...55 °C (32...131 °F) | |
Flat/Book (Top) mounting: 0...50 °C (32...122 °F) | ||
Storage temperature | -30...70 °C (-22...158 °F) | |
Ambient air and storage humidity | 10...90% RH (non condensing, wet bulb temperature 39 °C [102.2 °F] or less) | |
Dust | 0.1 mg/m3 (10-7 oz/ft3) or less (non-conductive levels) | |
Pollution degree | For use in Pollution Degree 2 environment | |
Corrosive gases | Free of corrosive gases | |
Atmospheric pressure (operating altitude) | 800...1,114 hPa (2,000 m [6,561 ft] or lower) | |
Mechanical environment | ||
Vibration resistance | IEC/EN 61131-2 compliant 5...9 Hz Single amplitude 3.5 mm (0.14 in) 9...150 Hz Fixed acceleration: 9.8 m/s2 X, Y, Z directions for 10 cycles (approximately 100 minutes) |
|
Shock resistance | IEC/EN 61131-2 compliant 147 m/s2, X, Y, Z directions for 3 times |
|
Electrical environment | ||
Electrical fast transient/burst immunity | IEC 61000-4-4 2 kV: Power port 1 kV: Signal ports |
|
Electrostatic discharge immunity | Contact discharge method: 6 kV Air discharge method: 8 kV (IEC/EN 61000-4-2 Level 3) |
Box Module (With HDD)
Physical environment | ||
Ambient air temperature (T-Code: T4) | Advanced Box | Wall/Book (Side) mounting: 0...45 °C (32...113 °F) with FAN kit*1 |
Flat/Book (Top) mounting: 0...45 °C (32...113 °F) with FAN kit*1 | ||
Standard Box | Wall/Book (Side) mounting: 0...40 °C (32...104 °F) | |
Flat/Book (Top) mounting: 0...40 °C (32...104 °F) | ||
Storage temperature | -30...70 °C (-22...158 °F) | |
Ambient air and storage humidity | 10...90% RH (non condensing, wet bulb temperature 39 °C [102.2 °F] or less) | |
Dust | 0.1 mg/m3 (10-7 oz/ft3) or less (non-conductive levels) | |
Pollution degree | For use in Pollution Degree 2 environment | |
Corrosive gases | Free of corrosive gases | |
Atmospheric pressure (operating altitude) | 800...1,114 hPa (2,000 m [6,561 ft] or lower) | |
Mechanical environment | ||
Vibration resistance | IEC/EN 61131-2 compliant 5...9 Hz Single amplitude 3.5 mm (0.14 in) 9...150 Hz Fixed acceleration: 4.9 m/s2 X, Y, Z directions for 10 cycles (approximately 100 minutes) NOTE: In an environment with vibrations, the read/write speed on the HDD
may decrease.
|
|
Shock resistance | IEC/EN 61131-2 compliant 147 m/s2, X, Y, Z directions for 3 times |
|
Electrical environment | ||
Electrical fast transient/burst immunity | IEC 61000-4-4 2 kV: Power port 1 kV: Signal ports |
|
Electrostatic discharge immunity | Contact discharge method: 6 kV Air discharge method: 8 kV (IEC/EN 61000-4-2 Level 3) |
*1 The FAN kit is required when using this product with HDD installed.
Panel Type (Without HDD)
Physical environment | ||
Ambient air temperature (T-Code: T4) | Advanced Model | Panel (Landscape) mounting: 0...55 °C (32...131 °F) with/without FAN kit (for 19” Wide, 0...50 °C (32...122 °F) with/without FAN kit) |
Panel (Portrait) mounting: 0...50 °C (32...122 °F) with/without FAN kit | ||
Standard Model | Panel (Landscape) mounting: 0...55 °C (32...131 °F) (for 19” Wide, 0...50 °C (32...122 °F)) |
|
Panel (Portrait) mounting: 0...50 °C (32...122 °F) | ||
Storage temperature | -20...60 °C (-4...140 °F) | |
Ambient air and storage humidity | 10...90% RH (non condensing, wet bulb temperature 39 °C [102.2 °F] or less) | |
Dust | 0.1 mg/m3 (10-7 oz/ft3) or less (non-conductive levels) | |
Pollution degree | For use in Pollution Degree 2 environment | |
Corrosive gases | Free of corrosive gases | |
Atmospheric pressure (operating altitude) | 800...1,114 hPa (2,000 m [6,561 ft] or lower) | |
Mechanical environment | ||
Vibration resistance | IEC/EN 61131-2 compliant 5...9 Hz Single amplitude 3.5 mm (0.14 in) 9...150 Hz Fixed acceleration: 9.8 m/s2 X, Y, Z directions for 10 cycles (approximately 100 minutes) |
|
Shock resistance | IEC/EN 61131-2 compliant 147 m/s2, X, Y, Z directions for 3 times |
|
Electrical environment | ||
Electrical fast transient/burst immunity | IEC 61000-4-4 2 kV: Power port 1 kV: Signal ports |
|
Electrostatic discharge immunity | Contact discharge method: 6 kV Air discharge method: 8 kV (IEC/EN 61000-4-2 Level 3) |
Panel Type (With HDD)
Physical environment | ||
Ambient air temperature (T-Code: T4) | Advanced Model | Panel (Landscape) mounting: 0...45 °C (32...113 °F) with FAN kit*1 |
Panel (Portrait) mounting: 0...45 °C (32...113 °F) with FAN kit*1 | ||
Standard Model | Panel (Landscape) mounting: 0...40 °C (32...104 °F) | |
Panel (Portrait) mounting: 0...40 °C (32...104 °F) | ||
Storage temperature | -20...60 °C (-4...140 °F) | |
Ambient air and storage humidity | 10...90% RH (non condensing, wet bulb temperature 39 °C [102.2 °F] or less) | |
Dust | 0.1 mg/m3 (10-7 oz/ft3) or less (non-conductive levels) | |
Pollution degree | For use in Pollution Degree 2 environment | |
Corrosive gases | Free of corrosive gases | |
Atmospheric pressure (operating altitude) | 800...1,114 hPa (2,000 m [6,561 ft] or lower) | |
Mechanical environment | ||
Vibration resistance | IEC/EN 61131-2 compliant 5...9 Hz Single amplitude 3.5 mm (0.14 in) 9...150 Hz Fixed acceleration: 4.9 m/s2 X, Y, Z directions for 10 cycles (approximately 100 minutes) NOTE: In an environment with vibrations,
the read/write speed on the HDD may decrease.
|
|
Shock resistance | IEC/EN 61131-2 compliant 147 m/s2, X, Y, Z directions for 3 times |
|
Electrical environment | ||
Electrical fast transient/burst immunity | IEC 61000-4-4 2 kV: Power port 1 kV: Signal ports |
|
Electrostatic discharge immunity | Contact discharge method: 6 kV Air discharge method: 8 kV (IEC/EN 61000-4-2 Level 3) |
*1 The FAN kit is required when using this product with HDD installed.
Air Quality Requirements
Do not operate or store the product where chemicals evaporate, or where chemicals are present in the air:
-
Corrosive chemicals: Acids, alkalines, liquids containing salt.
-
Flammable chemicals: Organic solvents.
![]() |
---|
INOPERATIVE
EQUIPMENT
Do not allow water, liquids, metal,
and wiring fragments to enter the panel case.
Failure to follow these instructions can result in injury or equipment damage.
|