 Restrictions of RPA feature


Click the followings to see the details of restrictions.

RPA Window Display Restrictions (Setting Up)
*
You can set up one RPA window display on one screen. Do not use [Call Screen] or any other features and display multiple RPA window displays. The entire project is limited to eight displays.
* You can set the RPA window display on only the base screen display. The RPA window display does not work even if you place one on the window screen.
* In "Remote PC Access Trigger Bit Address", the window opens when the bit is ON, and closes when the bit is OFF. To turn ON or OFF, the trigger bit takes more than one communication cycle or display scan time to find the bit state.
*
The RPA window display uses one local window. Therefore, you can display up to 2 local windows (if you use the global window in the local window, you can display up to 3) on the window parts and the RPA window display at the same time. If you display 2 local windows on the window parts, you cannot display on the RPA window display.
* If you display the RPA window display, only one window part can be allocated to the same screen. The start sequence for the window part and the RPA window display must have the start bit turn on first. If the start bit is turned on at the same time, which parts will be displayed first cannot be controlled.
* The RPA window display is displayed in the same direction as [Landscape], even if you set [Portrait] in for the [Orientation].