Environmental Specifications
-
When using any of the options for this product, check the specifications for special conditions or cautions that may apply to this product.
-
For Wall/ Flat/ Book (Top/Side) mounting and Panel (Landscape/Portrait) mounting, refer to Installation and Wiring.
Box Module (Without HDD)
Physical environment | ||
Ambient air temperature (T-Code: T4) | Advanced Box | Wall/Book (Side) mounting: 0...55 °C (32...131 °F) with/without FAN kit |
Flat/Book (Top) mounting: 0...50 °C (32...122 °F) with/without FAN kit | ||
Standard Box | Wall/Book (Side) mounting: 0...55 °C (32...131 °F) | |
Flat/Book (Top) mounting: 0...50 °C (32...122 °F) | ||
Storage temperature | -30...70 °C (-22...158 °F) | |
Ambient air and storage humidity | 10...90% RH (non-condensing, wet bulb temperature 39 °C [102.2 °F] or less) | |
Dust | 0.1 mg/m3 (10-7 oz/ft3) or less (non-conductive levels) | |
Pollution degree | For use in Pollution Degree 2 environment | |
Corrosive gases | Free of corrosive gases | |
Atmospheric pressure (operating altitude) | 800...1,114 hPa (2,000 m [6,561 ft] or lower) | |
Mechanical environment | ||
Vibration resistance | IEC/EN 61131-2 compliant 5...9 Hz Single amplitude 3.5 mm (0.14 in) 9...150 Hz Fixed acceleration: 9.8 m/s2 X, Y, Z directions for 10 cycles (approximately 100 minutes) |
|
Shock resistance | IEC/EN 61131-2 compliant 147 m/s2, X, Y, Z directions for 3 times |
|
Electrical environment | ||
Electrical fast transient/burst immunity | IEC 61000-4-4 2 kV: Power port 1 kV: Signal ports |
|
Electrostatic discharge immunity | Contact discharge method: 6 kV Air discharge method: 8 kV (IEC/EN 61000-4-2 Level 3) |
Box Module (With HDD)
Physical environment | ||
Ambient air temperature (T-Code: T4) | Advanced Box | Wall/Book (Side) mounting: 0...45 °C (32...113 °F) with FAN kit*1 |
Flat/Book (Top) mounting: 0...45 °C (32...113 °F) with FAN kit*1 | ||
Standard Box | Wall/Book (Side) mounting: 0...40 °C (32...104 °F) | |
Flat/Book (Top) mounting: 0...40 °C (32...104 °F) | ||
Storage temperature | -30...70 °C (-22...158 °F) | |
Ambient air and storage humidity | 10...90% RH (non-condensing, wet bulb temperature 39 °C [102.2 °F] or less) | |
Dust | 0.1 mg/m3 (10-7 oz/ft3) or less (non-conductive levels) | |
Pollution degree | For use in Pollution Degree 2 environment | |
Corrosive gases | Free of corrosive gases | |
Atmospheric pressure (operating altitude) | 800...1,114 hPa (2,000 m [6,561 ft] or lower) | |
Mechanical environment | ||
Vibration resistance | IEC 60068-2-6 compliant 5...9 Hz Single amplitude 1.75 mm (0.07 in) 9...150 Hz Fixed acceleration: 4.9 m/s2 X, Y, Z directions for 10 cycles (approximately 100 minutes) NOTE: In an environment with vibrations, the read/write speed on the HDD
may decrease.
|
|
Shock resistance | IEC/EN 61131-2 compliant 147 m/s2, X, Y, Z directions for 3 times |
|
Electrical environment | ||
Electrical fast transient/burst immunity | IEC 61000-4-4 2 kV: Power port 1 kV: Signal ports |
|
Electrostatic discharge immunity | Contact discharge method: 6 kV Air discharge method: 8 kV (IEC/EN 61000-4-2 Level 3) |
*1 The FAN kit is required when using this product with HDD installed.
Panel Type (Without HDD)
Physical environment | ||
Ambient air temperature (T-Code: T4) | Advanced Model | Panel
(Landscape) mounting: 0...55 °C (32...131 °F) with/without FAN kit (for 19-inch Wide and 22-inch Wide: 0...50 °C (32...122 °F) with/without FAN kit) |
Panel (Portrait) mounting: 0...50 °C (32...122 °F) with/without FAN kit | ||
Standard Model | Panel
(Landscape) mounting: 0...55 °C (32...131 °F) (for 19-inch Wide and 22-inch Wide: 0...50 °C (32...122 °F)) |
|
Panel (Portrait) mounting: 0...50 °C (32...122 °F) | ||
Storage temperature | -20...60 °C (-4...140 °F) | |
Ambient air and storage humidity | 10...90% RH (non-condensing, wet bulb temperature 39 °C [102.2 °F] or less) | |
Dust | 0.1 mg/m3 (10-7 oz/ft3) or less (non-conductive levels) | |
Pollution degree | For use in Pollution Degree 2 environment | |
Corrosive gases | Free of corrosive gases | |
Atmospheric pressure (operating altitude) | 800...1,114 hPa (2,000 m [6,561 ft] or lower) | |
Mechanical environment | ||
Vibration resistance | IEC/EN 61131-2 compliant 5...9 Hz Single amplitude 3.5 mm (0.14 in) 9...150 Hz Fixed acceleration: 9.8 m/s2 X, Y, Z directions for 10 cycles (approximately 100 minutes) NOTE: The vibration resistance when using the 22-inch Wide model with PCI/PCIe slots attached
is as follows.
IEC 60068-2-6 compliant 5...9 Hz Single amplitude 1.75 mm (0.07 in) 9...150 Hz Fixed acceleration: 4.9 m/s2 X, Y, Z directions for 10 cycles (approximately 100 minutes) |
|
Shock resistance | IEC/EN 61131-2 compliant 147 m/s2, X, Y, Z directions for 3 times |
|
Electrical environment | ||
Electrical fast transient/burst immunity | IEC 61000-4-4 2 kV: Power port 1 kV: Signal ports |
|
Electrostatic discharge immunity | Contact discharge method: 6 kV Air discharge method: 8 kV (IEC/EN 61000-4-2 Level 3) |
Panel Type (With HDD)
Physical environment | ||
Ambient air temperature (T-Code: T4) | Advanced Model | Panel (Landscape) mounting: 0...45 °C (32...113 °F) with FAN kit*1 |
Panel (Portrait) mounting: 0...45 °C (32...113 °F) with FAN kit*1 | ||
Standard Model | Panel (Landscape) mounting: 0...40 °C (32...104 °F) | |
Panel (Portrait) mounting: 0...40 °C (32...104 °F) | ||
Storage temperature | -20...60 °C (-4...140 °F) | |
Ambient air and storage humidity | 10...90% RH (non-condensing, wet bulb temperature 39 °C [102.2 °F] or less) | |
Dust | 0.1 mg/m3 (10-7 oz/ft3) or less (non-conductive levels) | |
Pollution degree | For use in Pollution Degree 2 environment | |
Corrosive gases | Free of corrosive gases | |
Atmospheric pressure (operating altitude) | 800...1,114 hPa (2,000 m [6,561 ft] or lower) | |
Mechanical environment | ||
Vibration resistance | IEC 60068-2-6 compliant 5...9 Hz Single amplitude 1.75 mm (0.07 in) 9...150 Hz Fixed acceleration: 4.9 m/s2 X, Y, Z directions for 10 cycles (approximately 100 minutes) NOTE: In an environment with vibrations, the read/write speed on the HDD
may decrease.
|
|
Shock resistance | IEC/EN 61131-2 compliant 147 m/s2, X, Y, Z directions for 3 times |
|
Electrical environment | ||
Electrical fast transient/burst immunity | IEC 61000-4-4 2 kV: Power port 1 kV: Signal ports |
|
Electrostatic discharge immunity | Contact discharge method: 6 kV Air discharge method: 8 kV (IEC/EN 61000-4-2 Level 3) |
*1 The FAN kit is required when using this product with HDD installed.
CAUTION |
---|
INOPERATIVE
EQUIPMENT
Failure to follow these instructions can result in injury or equipment damage.
|