Connection devices that the Ladder Monitor is available with and versions of the programming tools
Supporting models
Mitsubishi Electric

OMRON
Maker
Series
CPU
Link Interface or CPU Direct
Communication Method *1
Device Name for
GP-Pro EX
*2
OMRON Corporation CS1 Series
CS1H-CPU67
CS1H-CPU66
CS1H-CPU65
CS1H-CPU64
CS1G-CPU45
CS1G-CPU44
CS1G-CPU43
CS1G-CPU42
CS1H-CPU67H
CS1H-CPU66H
CS1H-CPU65H
CS1H-CPU64H
CS1H-CPU63H
CS1G-CPU45H
CS1G-CPU44H
CS1G-CPU43H
CS1G-CPU42H
CS1H-CPU67-V1
CS1H-CPU66-V1
CS1H-CPU65-V1
CS1H-CPU64-V1
CS1H-CPU63-V1
CS1G-CPU45-V1
CS1G-CPU44-V1
CS1G-CPU43-V1
CS1G-CPU42-V1
RS-232C port on CPU unit
RS232C or RS422/485
(4 wire)
CS/CJ Series
HOST Link
(Ver.1.13.02 or later)
Peripheral port on CPU unit
Ethernet CS/CJ Series
Ethernet
(Ver.1.14.03 or later)
CS1W-SCU21
CS1W-SCU21-V1
CS1W-SCB21
CS1W-SCB41

CS1W-ETN01
CS1W-ETN11
CS1W-ETN21 *3
CJ1 Series
CJ1G-CPU45
CJ1G-CPU44
CJ1M-CPU23
CJ1M-CPU22
CJ1M-CPU21
CJ1M-CPU13
CJ1M-CPU12
CJ1M-CPU11
CJ1H-CPU67H
CJ1H-CPU66H
CJ1H-CPU65H
CJ1H-CPU67H-R
CJ1H-CPU66H-R
CJ1H-CPU65H-R
CJ1H-CPU64H-R
CJ1G-CPU45H
CJ1G-CPU44H
CJ1G-CPU43H
CJ1G-CPU42H
RS-232C port on CPU unit
RS232C or RS422/485
(4 wire)
CS/CJ Series
HOST Link
(Ver.1.13.02 or later)
Peripheral port on CPU unit
CS/CJ Series
Ethernet
(Ver.1.14.03 or later)
CJ1W-SCU41
CJ1W-SCU41
CJ1W-SCU21
CJ1W-SCU41-V1
CJ1W-SCU31-V1
CJ1W-SCU21-V1
CS1W-ETN01
CS1W-ETN11
CS1W-ETN21 *3
Ethernet
CP1 Series
CP1L-M□□D□-□
CP1L-L□□D□-□
CP1W-CIF01
RS232C CS/CJ Series
HOST Link
(Ver.1.13.02 or later)
CP1W-CIF11
RS422/485
(4 wire)
CP1H-X□□D□-□
CP1H-XA□□D□-□
CP1H-Y□□D□-□
CP1W-CIF01
RS232C or RS422/485
(4 wire)
CS/CJ Series
Ethernet
(Ver.1.14.03 or later)
CP1W-CIF11
CJ1W-SCU41
CJ1W-SCU21
CJ1W-SCU41-V1
CJ1W-SCU31-V1
CJ1W-SCU21-V1
CJ1W-ETN21 *3
Ethernet

OMRON Programming Tool

  • CX-Programmer Series Ver.7 or lower
IMPORTANT
-
If the driver version of the connected device, that is installed in GP-Pro EX is older than that listed in the table above, the ladder monitor will not function normally.
Upgrade the driver to at least the version listed in the table before using the unit.
The update module can be downloaded from our website "Otasuke Pro!"
> PLC Drivers

NOTE
-
This information is as of November 2008.
-
Instructions that can be monitored using this function are those supported by the CX-Programmer Series Ver.7 programming tool or lower by OMRON Corporation.
*1
The communication method changes depending on the type of the link unit, cables used, etc. For the details, see the driver manual.
*2
The driver version can be checked by viewing [Peripheral List] in the System Settings window of GP-Pro EX, or [Driver Version] in the Offline mode on the display unit.
*3
Compatible with both Ethernet transfer protocols, UDP/IP, and TCP/IP.