Connection devices that the Ladder Monitor is available with and versions of the programming tools
Supporting models
Mitsubishi Electric
Maker
Series
CPU
Link Interface or CPU Direct
Communication Method *1
Device Name for
GP-Pro EX
*2
Mitsubishi Electric Corporation Q Series
Q02
Q02H
Q06H
Q12H
Q25H
RS-232C port on CPU unit
- Mitsubishi Electric
Q Series CPU Direct
(Ver.1.13.07 or later)
QJ71E71
Ethernet
(UDP)
Mitsubishi Electric
Q/QnA Series
Ethernet
(Ver.1.12.04 or later)
QJ71E71-B2
Ethernet
(UDP)
QJ71E71-100
Ethernet
(UDP)
Q Series
(A Mode)
Q02CPU-A
Q02HCPU-A
CPU Direct
RS232C or RS422/485
(4 wire)
Mitsubishi Electric
A Series CPU Direct
(Ver.1.13.02 or later)
A1SJ71C24-R2
A1SJ71C24-R4
A1SJ71UC24-R2
A1SJ71UC24-R4
Mitsubishi Electric
A Series Computer Link
(Ver.1.12.02 or later)
AnA Series
A2ACPU
A2ACPU-S1
A3ACPU
A2UCPU
A2UCPU-S1
A3UCPU
A4UCPU

CPU Direct

RS232C or RS422/485
(4 wire)
Mitsubishi Electric
A Series CPU Direct
(Ver.1.13.02 or later)
AJ71C24-S6
AJ71C24-S6
AJ71C24-S6
Mitsubishi Electric
A Series Computer Link
(Ver.1.12.02 or later)
A2USCPU
A2USCPU-S1

CPU Direct

RS232C or RS422/485
(4 wire)
Mitsubishi Electric
A Series CPU Direct
(Ver.1.13.02 or later)
A1SJ71C24-R2
A1SJ71C24-R4
A1SJ71UC24-R2
A1SJ71UC24-R4
Mitsubishi Electric
A Series Computer Link
(Ver.1.12.02 or later)

Mitsubishi Electric Programming Tool

  • MELSOFT GX Series GX Developer Ver.8
IMPORTANT
-
If the driver version of the connected device, that is installed in GP-Pro EX is older than that listed in the table above, the ladder monitor will not function normally.
Upgrade the driver to at least the version listed in the table before using the unit.
The update module can be downloaded from our website "Otasuke Pro!"
> PLC Drivers

NOTE
-
This information is as of November 2008.
-
Instructions that can be monitored using this function are those supported by the MELSOFT GX Series GX Developer Ver.8 programming tool by Mitsubishi Electric Corporation.
*1
The communication method changes depending on the type of the link unit, cables used, etc. For the details, see the driver manual.
*2
The driver version can be checked by viewing [Peripheral List] in the System Settings window of GP-Pro EX, or [Driver Version] in the Offline mode on the display unit.