 A screen on GP-Viewer EX does not perform normally. * Asynchronous Mode

If LS15 of the memory link address, or LS8 when communicating with a connection device, is used for the feature which runs in the background such as Global D-Script and a logic program when operating GP-Viewer EX in "Asynchronous Mode", a screen on GP-Viewer EX may not perform normally. In case that you cannot change screens normally, change screens only by using a screen change switch or disable screen changes from a client.

Click here to see how to disable screen changes from a client.