A.1.1.4 LS9000 Area (Direct Access Method)

The following lists the data contents stored in the LS9000 Area.

Display Unit Internal Address

Description

Introduction

H System Variable

LS9000 to

Display Historical Graph Data

Historical data numbers and data values

-

LS9100 to

Script Process

Script error code

-

LS9200 to

CSV Data Transfer Feature

Number and file number of CSV data files transferred by the Condition Name Search Feature

-

LS9210 - LS9211

Number of lines you can print on the printer

Number of lines of text you can print and number of lines already printed

-

LS9212 to

Reserved

Reserved

-

LS9230 to

VM Unit serial mouse feature

Serial mouse touch state and coordinates

-

LS9235 to

Touch Coordinates

Touch coordinates on display unit screen

-

LS9240 to

Reserved

Reserved

-

LS9260 to

LS9272 - LS9274

MAC Address

MAC Address

-

LS9280 to

Reserved

Reserved

-

LS9290 to

LS9300 to

Security feature

Security Level

-

LS9310 to

Day of the Week

Day of the Week

#H_CurrentDayofTheWeek

LS9320 to

Reserved

Reserved

-

LS9330 to

LS9350 to

RGB 2ch Serial Mouse Feature

Touch state and coordinates of RGB unit serial mouse

-

LS9370 to

Reserved

Reserved

-

LS9400 to

Communication Cycle Time
4 drivers x 32 devices
*1

Communication cycle time of device/PLC

[PLC*]#H_DriverCycleTime

LS9528 to

Reserved

Reserved

-

LS9550 to

Communication Scan ON/OFF Control
4 drivers x 32 devices
*1

Device/PLC communication scan ON/OFF

[PLC*]#H_ScanOffControl

LS9558 to

Reserved

Reserved

-

LS9560 to

Communication Scan ON/OFF Status
4 drivers x 32 devices
*1

Device/PLC communication scan status

[PLC*]#H_ScanOffStatus

LS9568

Reserved

Reserved

-

LS9800 to LS9815

Alarm Polling Cycle Information

Actual measured polling time and average time of each block when extended alarm is enabled

-

LS9920 to

Reserved

Reserved

-

LS9930 to

LS9940 to LS9943

LS9944

LS9945 to LS9946

LS9950

Reserved

Reserved

-

LS9951

RemoteHMI client connection state

Number of Pro-face Remote HMI clients connected to WinGP via Pro-face Remote HMI Server (application)

-

LS9952

Write filter (write protection) settings

Enable/Disable write filter (write protection) on the SP5000 Series Open Box

-

LS9953

Screen data operation drive

Drive that stores screen data

-

LS9954

SMTP send timeout

Timeout value for a sending e-mail task

-

LS9955

GP-4G01 Clear Error

Clear error history

-

LS9970 to LS9999

Reserved

Reserved

-

*1 H system variables store content from the 33rd item and beyond.

Details About Each Address

In the [Historical Trend Graph] part, select the [Display Historical Data] check box to display the data numbers and values for the oldest and newest data on the graph display area.

19.8.3 Display Historical Data

The following data is stored in Script process area.

LS9100

Extended script error code

22.10.6 Errors

LS9101

Extended script error status

LS9102 to LS9109

Reserved

LS9110

Global D Script error code

22.10.6 Errors

LS9111

Global D-Script error status

LS9112 to LS9119

Reserved

LS9120

D Script error code

22.10.6 Errors

LS9121

D Script error status

LS9122 to LS9129

Reserved

LS9130

Data Storage Mode

22.10.7 Data Storage Mode

LS9131

Reserved

LS9132

CF list status, SD list status

LS9133

CF read status, SD read status

LS9134

CF write status, SD write status

LS9135

CF delete status, SD delete status

LS9136

CF rename status, SD rename status

LS9137

CF CSV read status, SD CSV read status

LS9138

USB list status

LS9139

USB read status

LS9140

USB write status

LS9141

USB delete status

LS9142

USB rename status

LS9143

USB CSV read status

22.11.7.7 Label Settings - External storage error detail status storage area

LS9144 to LS9149

Reserved

LS9150

Block ring shift status

22.11.2.6 Memory Ring

LS9151

Block clear shift status

22.11.2.11 Shift Memory

LS9152

Block memory comparison status

22.11.2.2 Compare Memory

LS9153

Block memory search status

22.11.2.2 Compare Memory

LS9154 to LS9159

Reserved

LS9160

File Copy Status

22.11.6.1 File Copy

LS9161 to LS9199

Reserved

 

Stores the number and the file number of CSV data transferred by the Condition Name Search Feature. You can get hits on the search when the search string matches the condition exactly.
Spaces indicate different file names and can cause errors. When data transfer is completed, the status and number of transferred files displays. The last transferred file numbers are written in the GP internal device Special Areas LS9200 and LS9201. (The Special Area is read-only.)

Stores the maximum number of lines of text per page and a line counter for the last text printed.

LS9210

Stores the maximum number of lines of text you can print per page.

When a value other than "0" is written, it is treated as the maximum number of lines of text you can print. The maximum number of lines you can print per page is 60 lines. If you set a value that exceeds 60, the 61st line and beyond is printed on the next page.

When the value is set as 0, the display unit calculates the maximum number of lines. 60 lines for A4 portrait orientation.

LS9211

Stores the number of lines that have been printed. When this value equals the value in LS9210, the paper is ejected and this counter is reset to 0.

 

Using DVI/VM unit, this feature stores the touch status and the touch coordinates when sending the touch coordinates to a PC by serial communication.

28.10.7.4 Emulate Touch Output

Stores the touch coordinates on a display screen.

LS9235

0: Touched status

1: Not-touched status

LS9236

X coordinate

LS9237

Y coordinate

 

The display coordinate range depends on the number of pixels on the display. The display coordinate range is fixed, no matter if you set up the display unit for portrait or landscape orientation. When using portrait orientation, you cannot store Y coordinates outside the following range.

X Coordinate Range

0 ... (Number of pixels on display width - 1)

Y Coordinate Range

0 ... (Number of pixels on display height - 1)

When the screen size is 320 x 240 pixels (QVGA)

X Coordinate Range: 0...319
Y Coordinate Range: 0...239

The MAC addresses for display units are stored as hexadecimal values in LS9272 - LS9274, starting from the first octet.

When bit 0 of LS9300 toggles from OFF to ON, the security level stored in LS9301 changes to 0.
After the Security Level Clear occurs, return LS9300's 0 bit to OFF. (LS9301 is read-only.)

Also, it stores the current security level and the security level of the screen to be displayed

LS9301 and LS9302 are read-only. When there is a password request in LS9302, the security level is stored and the value returns to 0 when the password input is complete.

Stores the current value of the day of the week. The day is calculated from the Year, Month, and Day of the display unit's onboard IC (RTC) clock. The values stored in LS9310 are as follows.

Numeric Value

Description

0

Sunday

1

Monday

2

Tuesday

3

Wednesday

4

Thursday

5

Friday

6

Saturday

After 7

Unused

Updates are performed when the IC clock date is changed. Because the writes do not occur regularly, when parts change in this area, this area is not updated until the IC clock date changes.

When the RGB unit is set to display 2 channels at the same time and is sending the touch coordinates to a PC by serial communication, it stores the touch status and coordinates.

28.10.7.4 Emulate Touch Output

Stores polling cycle time (in milliseconds) of the configured Device/PLC.

5.4.14 System Settings [Peripheral List] Settings Guide

Controls whether to run or stop the communication scan with the configured Device/PLCs.

5.4.14 System Settings [Peripheral List] Settings Guide

Stores the communication scan status of the configured Device/PLC

7.3.2 Procedure - Confirming the Communication State

Stores the actual measured polling time and average time of each block when extended alarm is enabled. Also sets the Polling Time Exceeded bit to 1 when the actual polling time exceeds the configured time.

20.12.1.2 Alarm Settings (Block 1) - Bit Monitoring

Stores the number of clients connected to WinGP via Pro-face Remote HMI Server (application). Pro-face Remote HMI clients that connect directly to WinGP are not included in the number of clients.

When WinGP is started, checks and saves every 5 seconds the write filter (write protection) status for the SP5000 Series Open Box's system card (C drive).

LS9952 bit 0 is OFF (stores 0): Write filter is disabled.

LS9952 bit 0 is ON (stores 1): Write filter is enabled.

When using WinGP, the drive from which screen data is loaded is stored.

Bit 0 in LS9953 is OFF: C drive

Bit 0 in LS9953 is ON: Other than C drive

When using E-mail feature, timeout value for a sending e-mail task is stored. The initial setting is 60 seconds.

Changing LS9955 bit 0 from OFF to ON clears the error history and turns the red ERR LED Light off.

Note that this clears the entire error history on the display unit.