Products
Download
Contact us
Back to Top

Driver Download

>PLCs >Siemens AG SIMATIC S7 MPI Direct Driver

Please acknowledge the following terms of use before you use our download service. Download of any file signifies your agreement to the terms of use.

Terms of Use
  1. Schneider Electric Japan Holdings Ltd. ("SEJH") shall retain all intellectual property rights to the files that SEJH provides for this service.
  2. Who, uses or plans to use SEJH's products, may download and use any file.
  3. Reproduction, disclosure, re-publication, assignment, lease, decompilation, modification, falsification or reuse of any file that SEJH provides for this service shall be prohibited.
    However, for manuals, samples, BMP images and CAD files, you may reprint, duplicate, quote a part of the content or the whole on your company's specification sheets, or instruction manuals for built-in products. Also you may change the layout of the content.
  4. This download service is provided through the Internet. Please acknowledge that SEJH provides no guarantee of the condition at the time of provision, the availability of access and the condition of use concerning this service before you use this service.
  5. Please use this service at your own risk.
  6. If any additional conditions such as service usage conditions are attached to the downloaded files, please comply with such conditions as well.
Notices:
  1. Files are subject to deletion, or modification of the contents or specifications without notice.
  2. Please confirm that the downloading file size completely accords with the download file size shown.
  3. If the file sizes do not match, delete the file without decompressing and then download the same file once again.
 Download

Note:

Precautions for adding a new driver onto Windows Vista/7
Precautions for adding a new driver at Daylight Saving Time

Title Siemens AG SIMATIC S7 MPI Direct Driver
Version Ver. 1.15.09
File Name SIE_MPID.exe
File Size 973KB
Applicable Software GP-Pro EX Ver. 1.10.000 or later
Pro-Server EX Ver. 1.10.000 or later
You can check your version by "Help" function -> "Version Info".
Related Devices
  • SIMATIC S7-200
  • SIMATIC S7-300
  • SIMATIC S7-400
Related Units
  • GP3000 Series
  • GP4100 Series (GP-Pro EX Ver. 2.60.000 or later)
Device/PLC Connection Manual For details, please read the following
PDF:sie_mpid.pdf ( 709KB )

For general information regarding Device connection and documentation conventions, please refer to "Device/PLC Connection Manual".
Updated Contents Ver. 1.15.09 (Jan. 31, 2011)
The following issue was corrected:
  • The improper address is displayed when sampling is specified
The following setting was added:

Installation (This file is self-extracting.)

  1. Please confirm that the supported software is installed in your computer. Prior to installing the driver, close all your personal computer applications, including any resident programs such as virus detection program, etc.
  2. Click on the above file name to download the data to desired folder.
  3. After the download to your PC is finished, double-click on the file's icon to start the installer program.
  4. After the installer starts, follow the instructions given on each screen.
  5. After installation, execute GP-Pro EX.
  6. After installation, click on the Device/PLC area's [Siemens AG] selection and
    select [SIMATIC S7 MPI Direct].
*
When using the driver, be sure to refer to the Device Connection Manual PDF (Shown above). Also, for general information regarding Device connection and documentation conventions please refer to "Device/PLC Connection Manual".

Update History:

[Ver. 1.15.09] (Jan. 31, 2011)

The following issue was corrected:
  • The improper address is displayed when sampling is specified
The following setting was added:

[Ver. 1.14.08] (Jan. 27, 2010)

The following issue was corrected:
  • Cannot read the Timer and Counter Devices.
The following setting was added:
  • Support GP4100 Series.
    * Ver. 2.60 of GP-Pro EX is necessary to use GP4100 Series.

[Ver. 1.13.06] (Jun. 12, 2009)

The following issue was corrected:
  • A communication error (RHxx131:Target Node Not Found) may occur when communicating with S7-200 PLC.

[Ver. 1.13.05] (Aug. 21, 2008)

The following issue was corrected:
  • A communication error may occur when communicating with S7-200 PLC.

[Ver. 1.13.04] (Feb. 27, 2008)

The following content has been improved.
  • Check timing of Token time-out.

[Ver. 1.13.03] (Aug. 30, 2007)

The following setting was added:

[Ver. 1.12.03] (May. 31, 2007)

The following issue was corrected:
  • Even if the power supply of PLC is turned off when Pro-Server EX is used, the error message is not displayed.

Last Updated : Jan. 31, 2011
Posted :May. 31, 2007

| Return to Top | | Back | HOME |
FAQ for use | Protection of Personal Information | Trademark Acknowledgments | About Intellectual Property Rights | Terms of Use
Copyright (C) 2005- Schneider Electric Japan Holdings Ltd. All Rights Reserved.