Products
Download
Contact us
Back to Top

Driver Download

>PLCs >LT3000 Series, USB/RS-422/485 Conversion Adapter Communication drivers addition installer

Please acknowledge the following terms of use before you use our download service. Download of any file signifies your agreement to the terms of use.

Terms of Use
  1. Schneider Electric Japan Holdings Ltd. ("SEJH") shall retain all intellectual property rights to the files that SEJH provides for this service.
  2. Who, uses or plans to use SEJH's products, may download and use any file.
  3. Reproduction, disclosure, re-publication, assignment, lease, decompilation, modification, falsification or reuse of any file that SEJH provides for this service shall be prohibited.
    However, for manuals, samples, BMP images and CAD files, you may reprint, duplicate, quote a part of the content or the whole on your company's specification sheets, or instruction manuals for built-in products. Also you may change the layout of the content.
  4. This download service is provided through the Internet. Please acknowledge that SEJH provides no guarantee of the condition at the time of provision, the availability of access and the condition of use concerning this service before you use this service.
  5. Please use this service at your own risk.
  6. If any additional conditions such as service usage conditions are attached to the downloaded files, please comply with such conditions as well.
Notices:
  1. Files are subject to deletion, or modification of the contents or specifications without notice.
  2. Please confirm that the downloading file size completely accords with the download file size shown.
  3. If the file sizes do not match, delete the file without decompressing and then download the same file once again.
 Download

Note:

Precautions for adding a new driver onto Windows Vista/7
Precautions for adding a new driver at Daylight Saving Time

Title LT3000 Series, USB/RS-422/485 Conversion Adapter Communication drivers addition installer
File Name LT3000_USBSerial_drivers.exe
File Size 19,121KB
Applicable Software GP-Pro EX Ver. 2.10.000 or later
Pro-Server EX Ver. 1.30.000 or later
You can check your version by "Help" function -> "Version Info".
Target driver
Communication driver Version LT3000
Series
USB/RS-422/485
Conversion Adapter
*1 *2
Digital Electronics Corporation General Ethernet V1.13.03 OK -
Digital Electronics Corporation Memory Link V1.18.10 OK *3 OK *4
Fatek Automation Corporation FB Series SIO
V1.12.01 OK OK
Fuji Electric Co.,Ltd. MICREX-F Series SIO V1.12.03 OK OK
Fuji Electric Co.,Ltd. MICREX-SX Series Ethernet V1.12.05 OK -
GE Intelligent Platforms Series 90 Ethernet V1.12.04 OK -
Hitachi, Ltd. S10 Series SIO V1.12.00 OK -
Hitachi, Ltd. S10V Series Ethernet V1.13.01 OK -
Hitachi IES Co.,Ltd. H Series Ethernet V1.13.03 OK -
Hitachi IES Co.,Ltd. H Series SIO V1.14.05 OK OK
JTEKT Corporation TOYOPUC CMP-LINK Ethernet V1.15.02 OK -
JTEKT Corporation TOYOPUC CMP-LINK SIO V1.15.03 OK OK
KEYENCE Corporation KZ-10_80RW/TW CPU Direct V1.12.00 OK -
KEYENCE Corporation KV-700/1000/3000/5000 CPU Direct V1.15.06 OK OK
KEYENCE Corporation KV-700/1000/3000/5000 Ethernet V1.14.03 OK -
KOYO ELECTRONICS INDUSTRIES KOSTAC/DL Series CCM SIO V1.12.01 OK OK
KOYO ELECTRONICS INDUSTRIES KOSTAC/DL Series MODBUS TCP V1.12.01 OK -
LS Industrial Systems Co., Ltd. XGT Series FEnet V1.13.02 OK -
MEIDENSHA Corporation UNISEQUE SERIES Ethernet V1.12.01 OK -
Mitsubishi Electric Corporation A Series CPU Direct V1.15.04 OK -
Mitsubishi Electric Corporation A Series Computer Link V1.15.04 OK OK *4
Mitsubishi Electric Corporation A Series Ethernet V1.12.02 OK -
Mitsubishi Electric Corporation FX Series Computer Link V1.14.01 OK OK *4
Mitsubishi Electric Corporation FX Series CPU Direct V1.15.08 OK OK *4 *5
Mitsubishi Electric Corporation FX Series Ethernet V1.12.00 OK -
Mitsubishi Electric Corporation Q Series CPU Direct V1.19.10 OK -
Mitsubishi Electric Corporation Q Series QnU CPU Ethernet V1.14.02 OK -
Mitsubishi Electric Corporation Q/QnA Serial Communication V1.14.04 OK OK *4
Mitsubishi Electric Corporation Q/QnA Series Ethernet V1.14.06 OK -
Mitsubishi Electric Corporation QnA Series CPU Direct V1.14.03 OK -
Mitsubishi Electric Corporation QUTE Series CPU Direct V1.14.04 OK -
Mitsubishi Heavy Industries DIASYS Netmation MODBUS TCP V1.12.03 OK -
OMRON Corporation C/CV Series HOST Link V1.13.06 OK OK *4
OMRON Corporation CS/CJ Series Ethernet V1.16.05 OK -
OMRON Corporation CS/CJ Series HOST Link V1.16.04 OK OK *4
Panasonic Electric Works SUNX FP Series Computer Link SIO V1.14.05 OK OK
Rockwell Automation DF1 V1.15.06 OK -
Rockwell Automation DH-485 V1.13.08 OK -
Saia-Burgess Controls Ltd. Saia S-Bus SIO V1.12.01 OK OK
Sanmei Electronics Co., Ltd. Si/CutyAxis Series SIO V1.13.01 OK OK
Schneider Electric SA MODBUS SIO Master V1.13.07 OK OK
Schneider Electric SA MODBUS Slave V1.16.07 OK
*3 *6
-
Schneider Electric SA MODBUS TCP Master V1.13.07 OK -
Schneider Electric SA Uni-Telway V1.13.05 OK -
SHARP MS Corporation JW Series Computer Link Ethernet V1.13.01 OK -
SHARP MS Corporation JW Series Computer Link SIO V1.12.01 OK OK
Siemens AG SIMATIC S7 Ethernet V1.16.08 OK -
TOSHIBA Corporation Computer Link Ethernet V1.12.00 OK -
TOSHIBA Corporation Computer Link SIO V1.11.00 OK OK
Shibaura Machine CO., LTD TC Series (TCmini/TC200) V1.14.03 OK OK
Yamatake Corporation MODBUS SIO Master V1.11.00 OK OK
YASKAWA Electric Corporation MEMOBUS Ethernet V1.14.02 OK -
YASKAWA Electric Corporation MEMOBUS SIO V1.14.05 OK OK
YASKAWA Electric Corporation MP Series SIO (Extension) V1.13.00 OK -

*1 When a USB/RS-422/485 Conversion Adapter is used, the communication cycle time is slower, compared with the case when the built-in COM port is used. Use the USB/RS-422/485 Conversion Adapter after checking the communication operation.
*2 To use a USB/RS-422/485 Conversion Adapter, GP-Pro EX Ver. 3.00.000 or later is required.
*3 When a logic executing time is long, the time to reply takes long. When time-out occurs to a Device/PLC of a master, make the time-out settings longer.
*4 To use a USB/RS-422/485 Conversion Adapter for these communication drivers, GP-Pro EX Ver. 3.01.200 or later is required.
*5 FX3UC is not supported.
*6 The Logic Time and the Scan Time are longer in the case of the SIO connection for approximately 30%. Use the SIO connection after checking the logic executing time.
Device/PLC Connection Manual For details, please read the Device/PLC Connection Manual installed in GP-Pro EX.

Please use a connection diagram of GP3000 (COM1) in Device/PLC Connection Manual when using the LT3000 Series.

For general information regarding Device connection and documentation conventions, please refer to "Device/PLC Connection Manual".
Updated Contents (Jul. 27, 2012)
The following functions were added:
  • LT3000 Series is supported.
  • USB/RS-422/485 Conversion Adapter is supported.
    * To use a USB/RS-422/485 Conversion Adapter, GP-Pro EX Ver. 3.00.000 or later is required.
    * For some communication drivers, GP-Pro EX Ver. 3.01.200 or later is required.

Installation (This file is self-extracting.)

  1. Please make sure that the supported software is installed. Prior to installion, close all applications running on a PC including any resident programs such as a virus detection program, etc.
  2. Click on the file name above to start downloading the file.
  3. After download is complete, double-click on the downloaded file to start installation.
  4. Follow the instructions on the screen.
  5. After installation, start GP-Pro EX/Pro-Server EX.
  6. After installation, select a Manufacturer and the series of the object in Device/PLC.
*
When using the driver, be sure to refer to the Device Connection Manual PDF (Shown above). Also, for general information regarding Device connection and documentation conventions please refer to "Device/PLC Connection Manual".

Update History:

(Jul. 27, 2012) New

The following functions were added:
  • LT3000 Series is supported.
  • USB/RS-422/485 Conversion Adapter is supported.
    * To use a USB/RS-422/485 Conversion Adapter, GP-Pro EX Ver. 3.00.000 or later is required.
    * For some communication drivers, GP-Pro EX Ver. 3.01.200 or later is required.

Posted : Jul. 27, 2012

| Return to Top | | Back | HOME |
FAQ for use | Protection of Personal Information | Trademark Acknowledgments | About Intellectual Property Rights | Terms of Use
Copyright (C) 2005- Schneider Electric Japan Holdings Ltd. All Rights Reserved.