Driver Download

>PLCs >Fuji Electric Co., Ltd. MICREX-SX Series Ethernet Driver

Please acknowledge the following terms of use before you use our download service. Download of any file signifies your agreement to the terms of use.

Terms of Use
  1. Schneider Electric Japan Holdings Ltd. ("SEJH") shall retain all intellectual property rights to the files that SEJH provides for this service.
  2. Who, uses or plans to use SEJH's products, may download and use any file.
  3. Reproduction, disclosure, re-publication, assignment, lease, decompilation, modification, falsification or reuse of any file that SEJH provides for this service shall be prohibited.
    However, for manuals, samples, BMP images and CAD files, you may reprint, duplicate, quote a part of the content or the whole on your company's specification sheets, or instruction manuals for built-in products. Also you may change the layout of the content.
  4. This download service is provided through the Internet. Please acknowledge that SEJH provides no guarantee of the condition at the time of provision, the availability of access and the condition of use concerning this service before you use this service.
  5. Please use this service at your own risk.
  6. If any additional conditions such as service usage conditions are attached to the downloaded files, please comply with such conditions as well.
Notices:
  1. Files are subject to deletion, or modification of the contents or specifications without notice.
  2. Please confirm that the downloading file size completely accords with the download file size shown.
  3. If the file sizes do not match, delete the file without decompressing and then download the same file once again.
 Download

Note:

Precautions for adding a new driver onto Windows Vista/7
Precautions for adding a new driver at Daylight Saving Time

Title Fuji Electric Co., Ltd. MICREX-SX Series Ethernet Driver
Version Ver. 1.10.03
File Name FUJSXETH.exe
File Size 1,031KB
Applicable Software GP-Pro EX Ver. 1.10.000 or later
Pro-Server EX Ver. 1.21.000 or later
You can check your version by "Help" function -> "Version Info".
Related Devices
  • MICREX-SX Series
Related Units
Device/PLC Connection Manual For details, please read the following
PDF:fujsxeth.pdf ( 801KB )

For general information regarding Device connection and documentation conventions, please refer to "Device/PLC Connection Manual".
Updated Contents Ver. 1.10.03 (Dec. 24, 2010)
The following issues were corrected:
  • In rare cases, a variable that have been allocated to a real address, is unmatched with the Fuji Electric Co. Ltd. Micrex-SX Series D300Win software.
  • In rare cases, the displayed address in the left side of the [Address] window is unfinished.
  • In rare cases, putting a comment or space in the IEC file will result in an error when importing.

Installation (This file is self-extracting.)

  1. Please confirm that the supported software is installed in your computer. Prior to installing the driver, close all your personal computer applications, including any resident programs such as virus detection program, etc.
  2. Click on the above file name to download the data to desired folder.
  3. After the download to your PC is finished, double-click on the file’s icon to start the installer program.
  4. After the installer starts, follow the instructions given on each screen.
  5. After installation, execute GP-Pro EX.
  6. After installation, click on the Device/PLC area’s [Fuji Electric Co., Ltd.] selection and select [MICREX-SX Series Ethernet].

In case of using a project, created with a version below than V1.10.03

It is necessary to reallocate a variable to a real address when using variable data.

Instructions on how to reallocate to real address.

  1. Open the project file with driver V1.10.03 or later, installed in GP-Pro EX.
  2. Open the “Variable List” dialog from the Individual Device Settings.
  3. Delete all of the worksheet(s)  (This will delete all Variable Data)
  4. Delete all Structure / Array (If there are Embedded Structures / 2D Arrays then the higher level must be deleted first.)
  5. Import / Re-enter Structures / Arrays
  6. Import / Re-enter Variables
  7. Click OK to close dialog
  8. Click OK to save new Variable Data
*
Please don’t close the “Variable List” dialog while doing the procedures above. If the “Variable List” dialog is closed, the allocated variables to the parts in the screen will become “-Undefined-“.

Update History:

[Ver. 1.10.03] (Dec. 24, 2010)

The following issues were corrected:
  • In rare cases, a variable that have been allocated to a real address, is unmatched with the Fuji Electric Co. Ltd. Micrex-SX Series D300Win software.
  • In rare cases, the displayed address in the left side of the [Address] window is unfinished.
  • In rare cases, putting a comment or space in the IEC file will result in an error when importing.

[Ver. 1.10.02] (Nov. 12, 2009)

The following issues were corrected:
  • GP-Pro EX may be forcibly terminated when the address input dialog is opened.
  • GP-Pro EX may stop responding when import is performed and variables are overwritten.

[Ver. 1.10.01] (May. 8, 2008)

The following issue was corrected:
  • When create structure in variable data, there is the case that display cannot communicate with PLC.

Last Updated : Dec. 24, 2010
Posted :Nov. 16, 2007