LT Series
   About the products for the abolition of UL1604 standard

Type C (GLC150-BG41-RSFL-24V) Specifications (End of sale: 2013/09/30)

Functional Specifications

Model (Global Code)GLC150-BG41-RSFL-24V (PFXGLC150BDC)
→Recommended Substitute
Type Monochrome LCD
Display Colors Blue-mode
Backlight CCFL
(Service life: more than 25,000 at 24 hr. operation)
Resolution 320 × 240 pixels
Nominal Display Area (mm) 115.2(W) × 86.4mm(H)
Contrast Control 8 levels of adjustment available via touch panel
Language Character Sets ASCII: (Code page 850) Alphanumeric (incl. European characters)
Chinese: (GB2312-80 codes) simplified Chinese fonts
Japanese: ANK 158, Kanji: 6962 (JIS Standards 1 & 2)
Korean: (KSC5601 - 1992 codes) Hangul fonts
Taiwanese: (Big 5 codes) traditional Chinese fonts
Text8 × 8 Dots 40 char. × 30 rows
8 × 16 Dots 40 char. × 15 rows
16 × 16 Dots 20 char. × 15 rows
32 × 32 Dots 10 char. × 7 rows
Character Sizes*1 8 × 8, 8 × 16, 16 × 16, 32 × 32 dots
Font Sizes Both height and width can be expanded 1, 2, 4, or 8 times
MemoryApplication FLASH EPROM 1MB
Data Backup SRAM 96KB - uses lithium battery*2
Control
Memory
Variable Data Area SRAM 32KB - uses lithium battery*2
(Including bit, integer, timer, counter)
Program Area FLASH EPROM 128KB
Clock Accuracy ± 65 seconds/month (at room temperature)
Touch Panel 16 × 12 keys/ screen - 1 or 2 point touch
  1. The display font will differ depending on which (language) character, or which size you select.
  2. A Lithium battery's lifetime is:
    10 years when the battery's ambient temperature is under 40℃
    4.1 years when the battery's ambient temperature is under 50℃
    1.5 years when the battery's ambient temperature is under 60℃
    When used for backup:
    Approximately 60 days, with a fully charged battery
    Approximately 6 days, with a half-charged battery

General Specifications

Model (Global Code)GLC150-BG41-RSFL-24V (PFXGLC150BDC)
ElectricalRated Voltage DC24V
Rated Voltage Range DC20.4 to 28.8V
Allowable Voltage Drop 10 ms or less
Power Consumption 20W max.
Rush Current 30A max.
Voltage Endurance AC1000V, 10mA for up to 1 minute
(between charging and FG terminals)
Insulation Resistance 20MΩ or higher at DC500V
(between charging and FG terminals)
EnvironmentalAmbient Operating
Temperature*1
0 to 50℃
Storage Temperature -20 to 60℃
Ambient Humidity 10 - 90% RH
(non-condensing wetbulb temperature 39℃ or less)
Storage Humidity 10 - 90% RH
(non-condensing wetbulb temperature 39℃ or less)
Dust 0.1mg/m3 or less (non-conductive levels)
Corrosive
Gasses
Free of corrosive gases
Atmospheric Endurance
(Operation Altitude)
800 to 1114hPa (2000 meters or lower)
Vibration Resistance Compatible with IEC61131-2
When vibration is NOT continuous:
10Hz to 57Hz 0.075mm, 57Hz to 150Hz 9.8m/s2
When vibration is continuous:
10Hz to 57Hz 0.035mm, 57Hz to 150Hz 4.9m/s2
X, Y, Z directions for 10 times (80min.)
Noise Immunity Noise Immunity:1500Vp-p
Pulse Duration: 1µs, Rise Time: 1ns
(via noise simulator)
Electrostatic
Discharge Immunity
Contact discharge of 6kV (IEC 61000-4-2 Level 3)
StructuralGrounding 100Ω or less, or your country's applicable standard
Rating Equivalent to IP65f (JEM1030), NEMA#250 TYPE 4X/12*2
External Dimensions
(mm)
207W × 157H × 75.8D
Weight 1.5kg (3.3lb) or less
Cooling Method Natural air circulation
  1. Ensure that the temperatures both at the display surface and inside the panel are within the prescribed ambient temperature range during use. Use at temperatures outside this range may lead to malfunction.
  2. Limited to the front face after installation in a panel. Testing equivalent to IP65f conditions has been performed; however, performance cannot be guaranteed for every type of environment. If the product is subjected to an oil mist over an extended period of time, even when using the oil designated in the tests, or if the product is subjected to an extremely low-viscosity cutting oil, some oil penetration may result due to peeling of the front sheet. If this occurs, a countermeasure is required. The same kind of penetration, or plastic deformation, may also occur with oils other than those designated. Confirm ambient environment prior to installation. Furthermore, rubber gaskets that have been used for extended periods of time, and those that have been scratched or soiled after panel installation, may not provide sufficient protection. It is recommended that the rubber gasket be replaced periodically to ensure stable protection.

Remote I/O (FLEX NETWORK) Specifications

This I/F unit's high-speed remote I/O (6Mbps/ 12Mbps) is so fast, you won't think you are using a remote connection. Up to 1008 I/O points can be connected, with a communication delay of only 0.94ms (for 512 points at 12Mbps). The network can be extended up to 400 meters (2 channels at 6Mbps).

Communication Configuration 1:N
Connection Method Multi-Drop Connection
Max. Distance 200m/channel at 6Mbps,
100m/channel at 12Mbps
Communication Method Cyclic Time Division, half-duplex
Communication Speed 6Mbps/ 12Mbps (selectable)
Communication I/F Differential, pulse-transformer isolation
Error Check Format verification, bit verification, CRC-12 verification
Max. Number of Nodes 63 (number of occupied points varies according to I/O units)

I/F Connector

Pin No.Signal Name
6 Channel 2 shield (SLD)
5 Channel 2 communication data (TR-)
4 Channel 2 communication data (TR+)
3 Channel 1 shield (SLD)
2 Channel 1 communication data (TR-)
1 Channel 1 communication data (TR+)

Serial I/F (SIO) Specifications

Serial I/F(SIO) Asynchronous: RS-232C/RS-422
Data Length: 7 or 8bits
Stop Bit: 1 or 2bits
Parity: none, odd or even
Transmission Rate: 2400 to 115.2Kbps

Recommended Connector Dsub 25-pin plug XM2A-2501 (Omron)
Recommended Cover Dsub 25-pin cover XM2S-2511 (Omron)
Jack Screw XM2Z-0071 (Omron)
* Use M2.6 × 0.45 coarse thread screws to mount.
Recommended Cable CO-MA-VV-SB5P 28AWG (Hitachi Cable, ltd)
Refer to "LT Editor V2.0 External Device Connection Manual" for external controller connection information.
*PDF Manual can be downloaded from "Otasuke Pro!"

I/O Connector Specifications

PinCodeSignal NameFront View
1 FG Frame ground
2 SD Send data (RS-232C)
3 RD Receive data (RS-232C)
4 RS Request send (RS-232C)
5 CS Clear send (RS-232C)
6 NC No connection
7 SG Signal ground
8 CD Carrier detect (RS-232C)
9 TRMX Termination (RS-422)
10 RDA Receive data A (RS-422)
11 SDA Send data A (RS-422)
12*1 RESERVE Reserve
13*1 RESERVE Reserve
14 VCC 5V ±5% output 0.25A
15 SDB Send data B (RS-422)
16 RDB Receive data B (RS-422)
17 NC No connection
18 CSB Clear send B (RS-422)
19 ERB Enable receive B (RS-422)
20 ER Enable receive (RS-232C)
21 CSA Clear send A (RS-422)
22 ERA Enable receive A (RS-422)
23 NC No connection
24 NC No connection
25 NC No connection
  1. Pins 12 and 13 are reserves. Do not connect anything to them.

Common I/F Specifications

Alarm Output

Contact Ratio AC125V at 0.15A (resistive load)
DC24V at 0.6A (resistive load)
Set Time (at 20℃) 4ms or less
Reset Time (at 20℃) 4ms or less
Min. Switching Load 1mA/DC5V
Initial Contact Resistance 100mΩ or less

Tool Connector

Tool Connector Asynchronous: TTL level non-procedural command
Connect data transfer cable for transferring data from LT Editor.

When LT Series is powered up and the system is booted, the relay of the alarm output circuit turns ON. When a major error or watchdog error occurs, this relay switch turns OFF. An external fail-safe circuit can be provided to monitor this relay output.

Note: This relay switch is OFF from the time the power is turned on until the LT Series system is booted. The external monitoring circuit must be started after the LT Seires system is booted.

A timer circuit, which recognizes a non-operating LT is required. Otherwise the alarm monitoring system should be booted up after turning on the LT power supply.
画像1

External Dimensions

Note: Panel thickness should be between 1.6 and 5.0 mm (0.06 to 0.02 in.), and should be based on the strength required to mount the LT to the panel.

LTシリーズ 外形寸法図 LT Series Type C Side Panel