LTシリーズ

 

 

Type H (GLC150-*41-AD*-24V) Specifications (End of sale: 2009/12/24)

Functional Specifications

Model (Global Code)GLC150-SC41-AD*K-24V (PFXGLC150SDH1*)
→Recommended Substitute
GLC150-BG41-AD*K-24V(PFXGLC150BDH1*)
GLC150-BG41-AD*C-24V(PFXGLC150BDH2*)
→Recommended Substitute
Type STN Color LCD Monochrome LCD
Display Colors 64 Colors Blue-mode
Backlight CCFL
(Service life: more than 36,000 at 24 hr. operation)
CCFL
(Service life: more than 25,000 at 24 hr. operation)
Resolution 320 × 240 pixels
Nominal Display Area (mm) 118.2(W) × 89.4mm(H) 115.2(W) × 86.4mm(H)
Contrast Control 8 levels of adjustment available via touch panel
Language Character Sets ASCII: (Code page 850) Alphanumeric (incl. European characters)
Chinese: (GB2312-80 codes) simplified Chinese fonts
Japanese: ANK 158, Kanji: 6962 (JIS Standards 1 & 2)
Korean: (KSC5601 - 1992 codes) Hangul fonts
Taiwanese: (Big 5 codes) traditional Chinese fonts
Text8 × 8 Dots 40 char × 30 rows
8 × 16 Dots 40 char × 15 rows
16 × 16 Dots 20 char × 15 rows
32 × 32 Dots 10 char × 7 rows
Character Sizes*1 8 × 8, 8 × 16, 16 × 16, 32 × 32 dots
Font Sizes Both height and width can be expanded 1, 2, 4, or 8 times
MemoryApplication FLASH EPROM 1MB
Data Backup SRAM 96KB - uses lithium battery*2
Control
Memory
Variable Data Area SRAM 32KB - uses lithium battery*2
(Including bit, integer, timer, counter)
Program Area FLASH EPROM 128KB
Clock Accuracy ± 65 seconds/month (at room temperature)
Touch Panel 16 × 12 keys/ screen - 1 or 2 point touch
  1. The display font will differ depending on which (language) character, or which size you select.
  2. Lithium battery's lifetime is:
    10 years when the battery's ambient temperature is under 40℃
    4.1 years when the battery's ambient temperature is under 50℃
    1.5 years when the battery's ambient temperature is under 60℃
    When used for backup:
    Approximately 60 days, with a fully charged battery
    Approximately 6 days, with a half-charged battery

General Specifications

Model (Global Code)GLC150-*41-AD*-24V (PFXGLC150*DH**)
ElectricalRated Voltage DC24V
Rated Voltage Range DC20.4 to 28.8V
Allowable Voltage Drop 10 ms or less
Power Consumption 20W max.
Rush Current 30A max.
Voltage Endurance AC1000V, 10mA for up to 1 minute
(between charging and FG terminals)
Insulation Resistance 20MΩ or higher at DC500V
(between charging and FG terminals)
EnvironmentalAmbient Operating
Temperature*1
0 to 50℃
Storage Temperature -20 to 60℃
Ambient Humidity 10 - 90% RH
(non-condensing wetbulb temperature 39℃ or less)
Storage Humidity 10 - 90% RH
(non-condensing wetbulb temperature 39℃ or less)
Dust 0.1mg/m3 or less (non-conductive levels)
Corrosive
Gasses
Free of corrosive gases
Atmospheric Endurance
(Operation Altitude)
800 to 1114hPa (2000 meters or lower)
Vibration Resistance ompatible with IEC61131-2
When vibration is NOT continuous:
10Hz to 57Hz 0.075mm, 57Hz to 150Hz 9.8m/s2
When vibration is continuous:
10Hz to 57Hz 0.035mm, 57Hz to 150Hz 4.9m/s2
X, Y, Z directions for 10 times (80min.)
Noise Immunity Noise Immunity:1500Vp-p
Pulse Duration: 1µs, Rise Time: 1ns
(via noise simulator)
Electrostatic
Discharge Immunity
Contact discharge of 6kV (IEC 61000-4-2 Level 3)
StructuralGrounding 100Ω or less, or your country's applicable standard
Rating Equivalent to IP65f (JEM1030), NEMA#250 TYPE 4X/12*2
External Dimensions
(mm)
207W × 157H × 75.8D
Weight 1.5kg (3.3lb) or less
Cooling Method Natural air circulation
  1. Ensure that the temperatures both at the display surface and inside the panel are within the prescribed ambient temperature range during use. Use at temperatures outside this range may lead to malfunction.
  2. Limited to the front face after installation in a panel. Testing equivalent to IP65f conditions has been performed; however, performance cannot be guaranteed for every type of environment. If the product is subjected to an oil mist over an extended period of time, even when using the oil designated in the tests, or if the product is subjected to an extremely low-viscosity cutting oil, some oil penetration may result due to peeling of the front sheet. If this occurs, a countermeasure is required. The same kind of penetration, or plastic deformation, may also occur with oils other than those designated. Confirm ambient environment prior to installation. Furthermore, rubber gaskets that have been used for extended periods of time, and those that have been scratched or soiled after panel installation, may not provide sufficient protection. It is recommended that the rubber gasket be replaced periodically to ensure stable protection.

DIO Interface Specifications

Iuput

Model (Global Code)GLC150-*41-AD*-24V (PFXGLC150*DH**)
Rated Voltage DC 24V
Max. Allowable Voltage DC 28.8V
Input Method Source/ Sink input
Rated Current 9 mA (DC24V) (IN0, IN2, IN4, IN6),
5 mA (DC24V) (Other input)
Input Impedance Approx. 2.7kΩ (IN0, IN2, IN4, IN6),
Approx. 4.7kΩ (Other input)
Input Derating *1
Operation Range ON Voltage: DC19V min., OFF Voltage: DC5V max.
Input Delay Time OFF→ON 0.5 to 20ms max., ON→OFF 0.5 to 20ms max.*2
Common Lines 2
Common Line Allocation 8 points/common
Input Points 16
Input Signal Display LED lights for each point ON (logic side)
Isolation Method Photocoupler Isolation
External Power Supply For Signal: DC 24V
  1. Exceeding the LT unit's input rated voltage may affect the input ON voltage, input points, or ambient operating temperature; and the input area may break from excessive heat. Use Input Derating within the range shown in the chart below, to prevent the LT from breaking down.
  2. Digital filter can be set at intervals of 0.5ms.

Output

ItemLC (Low Current)
OUT0 to OUT7
HC (High Current)
OUT8 to OUT15
Rated Voltage DC 24V
Rated Voltage Range DC 20.4V to DC 28.8V
Output MethodType H1 Sink Output
Type H2 Source Output
Maximum Load Current 0.2A/point, 0.8A/common 0.5A/point, 2A/common
Output Voltage Drop 0.5V max.
Output Delay OFF→ON: 0.5ms max. ON→OFF: 0.5ms max.
Leakage Current when OFF0.1 mA max.
Output Classification Transistor Output
Common 1 each (OUT 0 to 7 = 1, OUT 8 to 15 = 1)
Common Structure 8 points/common
Output Protection Classification No protection
Internal Fuse 2A Chip Fuse
(non-replaceable)
5A Chip Fuse
(non-replaceable)
Surge Suppression Circuit Zener Diode (DC39V+/-1V)
Output Signal Indication LED lights when each point turns ON (logical side)
Isolation Method Photocoupler Isolation
External Power Supply For Signal: DC 24V

DIO Interface Connector Specifications

DIO Connector (Type H*-AD/ADP/ADT)

PIN No.Signal NamePIN No.Signal NamePin Assignments*1
A1 OUT15 B1 IN15
A2 OUT14 B2 IN14
A3 OUT13 B3 IN13
A4 OUT12 B4 IN12
A5 OUT11 B5 IN11
A6 OUT10 B6 IN10
A7 OUT9 B7 IN9
A8 OUT8 B8 IN8
A9 COM3 B9 COM1
A10 OUT7 B10 IN7
A11 OUT6 B11 IN6 (CT3)
A12 OUT5 B12 IN5
A13 OUT4 B13 IN4 (CT2)
A14 OUT3 (PLS3, PWM3) B14 IN3
A15 OUT2 (PLS3, PWM2) B15 IN2 (CT1)
A16 OUT1 (PLS3, PWM1) B16 IN1
A17 OUT0 (PLS3, PWM0) B17 IN0 (CT0)
A18 COM2 B18 COM0
  1. Parenthesized signal names ( ) indicate when Pulse output (PLS*), PWM output (PWM*), or Counter Input (CT*) are used. Using LT Editor, you can set the standard DIO for use as high-speed counter input. Refer to the LT Type H Series I/O Setting User's Manual for setting details.
Type H1-AD/ADP/ADT Input/Output Circuit (Sink IN and Source IN/Sink OUT)

Type H2-AD/ADP/ADT Input/Output Circuit (Sink IN and Source IN/Source OUT)

About COM

PIN No.Signal NameFunction
B18 COM0 Input Common (For IN0 to IN7) (For CT0 to CT3)
B9 COM1 Input Common (For IN8 to IN15)
A18 COM2 Output Common
(For OUT0 to OUT7) (For PLS0 to PLS3, PWM0 to PWM3)
A9 COM3 Output Common (For OUT8 to OUT15)

2L3.5/36LH 36 pole spring-clamp connector (Weidmuller) Wire size: 0.3mm to 1.0mm (AWG#18 to AWG#22)
* The terminals for DIO power supply are located on the analog input/output connector.

Common Interface Specifications

Alarm Output

Contact Ratio AC125V at 0.15A (resistive load), DC24V at 0.6A (resistive load)
Set Time (at 20℃) 4ms or less
Reset Time (at 20℃) 4ms or less
Min. Switching Load 1mA/ DC5V
Initial Contact Resistance 100mΩ or less

Tool Connector

Tool Connector Asynchronous: TTL level non-procedural command
Connect data transfer cable for transferring data from LT Editor.

When LT Series is powered up and the system is booted, the relay of the alarm output circuit turns ON. When a major error or watchdog error occurs, this relay switch turns OFF. An external fail-safe circuit can be provided to monitor this relay output.

Note: This relay switch is OFF from the time the power is turned on until the LT Series system is booted. The external monitoring circuit must be started after the LT Seires system is booted.

A timer circuit, which recognizes a non-operating LT is required. Otherwise the alarm monitoring system should be booted up after turning on the LT power supply.

Analog Input/Output Specifications

Input

ItemSpecifications
No. of Input Channels 2 Channels
Input Range At Voltage Setup: 0V to 10V (10.2375V max.)
At Current Setup: 0mA to 20mA (20.475mA max.)*1
ResolutionAt Voltage Setup 12 Bit (0 to 4000 (0V to 10V), 4095 max. (at 10.2375V))
At Current Setup 12 Bit (0 to 4000 (0mA to 20mA), 4095 max. (at 20.475mA))
Accuracy ± 1.0% of full scale (0 ℃ to 50 ℃)
Linearity ± 3 LSB max.
Input Impedance At Voltage Setup: 100kΩ, At Current Setup: 250Ω
Input Delay Time 40ms/2 Channels
Absolute Max. Input Voltage DC15V (Voltage)/ 60mA (Current)
Input Filter Move average sampling time 2ms
Power Supply DC24V External Power Supply
Insulation Each channel - Internal: Insulation
Between each channel: No insulation
Each channel - Analog Power: Insulated
Input/Ouput Characteristics
  1. Switching the Voltage Input or Current Input can be set separately, in each channel.
  2. When the Current Input is selected, ground AI* and AI* JP.
  3. Connct to the FG terminal in the main unit, or connect directly to frame groud (FG).

Output

ItemSpecifications
No. of Output Channels AD: 1 Channel/ ADP: 2 Channels/ ADT: 2 Channels
Output Range At Voltage Setup: 0V to 10V (10.2375V max.)
At Current Setup: 0mA to 20mA (20.475mA max.)*1
ResolutionAt Voltage Setup 12 Bit (0 to 4000 (0V to 10V), 4095 max. (at 10.2375V))
At Current Setup 12 Bit (0 to 4000 (0mA to 20mA), 4095 max. (at 20.475mA))
Accuracy ± 1.0% of full scale (0℃ to 50℃)
External Allowable Load At Voltage Setup: 10kΩ min., At Current Setup: 500Ω max.
Power Supply DC24V External Power Supply
Insulation Each channel - Internal: Insulation
Between each channel: No insulation
Each Analog Power channel: Insulation
Input/Ouput Characteristics
  1. Switching the Voltage Input or Current Input can be set separately, in each channel.

Important: Use twisted and shielded 2-conductor cable for analog input wiring, and do not route it near high-voltage, high-current, high-frequency cables (such as those for inverters) or power cables. Also, do not bundle it with any of these cables; place them in separate wiring ducts.

Input/Output Connector*1

PIN No.Signal NameConditionPin Assignments*2
124V DIO Power 24V
20V DIO Power 0V
3FE Terminal for Function Ground
424V Analog Power 24V
50V Analog Power 0V
6A02I Ch2 Analog Output (Current)
7A02V Ch2 Analog Output (Voltage)
8A0G Analog Output Ground
9A01I Ch1 Analog Output (Current)
10A01V Ch1 Analog Output (Voltage)
11AIG2 Analog Input Ground
12A12 JP Ch2 Analog Input
13AI2 + Ch2 Analog Input
14AIG1 Analog Input Ground
15AI1 JP Ch1 Analog Input
16AI1 + Ch1 Analog Input
  1. A connector terminal block is included with the unit, and is also available separately as a maintenance option.
  2. Applicable connector: Weidmuller BL3.5/16LH 16-terminal screw clamp. Max. connectable wire size: 1.6 mm (AWG#14)
Analog Input Circuit

Analog Output Circuit

High-speed Counter Input Specifications

ItemSpecifications
Counter Input DC 24V (Open Collector)
Single Phase (4 points) 2-Phase (1 point)/ Single Phase (2 points)
Counter Input Method Counter Input Method CT0 (IN0), CT1 (IN2), CT2 (IN4), CT3 (IN6), CT2 (IN4), CT3(IN6) CT0 (IN0), CT1 (IN2) are used as a pair
CT0: APhase,
CT1: B Phase
Input Voltage ON Voltage: DC19V min./ OFF Voltage: DC5V max.
Input Impedance 2.7 kΩ
Minimum Pulse Width
(Pulse Input)
Calculated Speed
(Rise and Fall time)
Phase 1 phase 90 degree phase differential -2 phase signal;
1 phase + directional signal
Max. Count Frequency 10kpps
Count Edge Assignment Available Not Available
Count Register 16 bit Up/Down counter
Counter Mode Switch Depending on software settings
Upper/ Lower Limit Setting Not available
Preload/Prestrobe Available
Marker Input
(Counter Value Clear)
None IN3

Temperature Input Connector Specifications

Pt100 Iuput

ItemSpecifications
Subjected Resistance
Temperature Sensor
Pt100
Measurable
Temperature Range
Celsius: -50℃ to 400℃ Fahrenheit: -58F to 752F
Accuracy ±1.0% (Full Scale)
No. of Input Channels 2 Channels
Temperature Convertion Data*1 Celsius: -500 to +4000 Fahrenheit: -580 to +7520
Conversion Time Approx. 85ms x filter frequency (1 to 64)*2
External Wiring Length Each Channel: 50m max.
InsulationChannel -
Channel
No Insulation
Input Part -
Internal Part
Photocoupler Insulation
Additional Function Linearize
Error Detection Temperature conversion data when exceeding measured temperature range
Exceeding the upper limit: 32767 Exceeding the lower limit: -32768
Wiring 3-wire method
Input/Ouput Characteristics
  1. Temperature conversion data is indicated as the measured value x10.
  2. Except for delay time, depending of the LT unit's scan time.

Temperature Input/ Output Connector*1

PIN No.Terminal NameConditionPin Assignments*2
1 PT1 A Pt100 Input Ch1
2 PT1 B Pt100 Input Ch1
3 PT1 B Pt100 Input Ch1
4 PT2 A Pt100 Input Ch2
5 PT2 B Pt100 Input Ch2
6 PT2 B Pt100 Input Ch2
  1. A connector terminal block is included with the unit, and is also available separately as a maintenance option.
  2. Applicable connector: Weidmuller BL3.5/16LH 16-terminal screw clamp. Max. connectable wire size: 1.6 mm (AWG#14)

Thermocouple Input Specifications

ItemSpecifications
Subjected Resistance
Temperature Sensor
Thermocouple (K/J Type)
Measurable
Temperature Range
J Type: Celsius: -100 to +700, Fahrenheit: -148 to +1292
K Type: Celsius: -100 to +1200, Fahrenheit: -148 to +2192
Accuracy ±1.0% (Full Scale)
No. of Input Channels 3 Channels
Temperature Convertion Data*1 J Type: Celsius: -1000 to +7000, Fahrenheit: -1480 to +12920
K Type: Celsius: -1000 to +12000, Fahrenheit: -1480 to +21920
External Wiring Length Each Channel: 50m max. (by compensating conductors)
Conversion Time Approx. 170ms x filter frequency (1 to 64) *2
Insulation No Insulation
Insulation Resistance Power for analog (DC24V) 1st side and 2nd side (AC500V)
Additional Function Linearize
Error Detection Temperature conversion data when exceeding measured temperature range
Exceeding the upper limit: 32767
Exceeding the lower limit: -32768
Disconnect Processing Temperature conversion data is 32767
Input/Ouput Characteristics
  1. Temperature conversion data is indicated as the measured value x10.
  2. Except for delay time, depending of the LT unit's scan time.

Termocouple Input Connector Specifications*1

PIN No.Terminal NameConditionPin Assignments*2
1 TC1+ Thermocouple Input Ch1
2 TC1- Thermocouple Input Ch1
3 TC2+ Thermocouple Input Ch2
4 TC2- Thermocouple Input Ch2
5 TC3+ Thermocouple Input Ch3
6 TC3- Thermocouple Input Ch3
  1. A connector terminal block is included with the unit, and is also available separately as a maintenance option.
  2. Applicable connector: Weidmuller BL3.5/16LH 16-terminal screw clamp. Max. connectable wire size: 1.6 mm (AWG#14)
Important: When extending the Pt100 input wire, make sure that the three conductors have exactly the same resistance and length. Do not route this wire near high-voltage, high-current, high-frequency cables (such as those for inverters) or power cables. Also, do not bundle it with any of these cables; place them in separate wiring ducts.
Pt100 input uses three conductors to eliminate wiring resistance and provide consistently precise measurement.
Important Do not route thermocouple input wiring near high-voltage, high-current, high-frequency cables (such as those for inverters) or power cables. Also, do not bundle it with any of these cables; place them in separate wiring ducts.
When extending the thermocouple input, use the specified (J type, K type) compensating lead wire. Because long compensating lead wires are subject to noise, the length should be kept as short as possible.
Make sure the compensating lead wire is connected with the correct polarity. If the polarity is reversed, temperature measurementswill be incorrect.
There is no insulation between thermocouple channels. Use insulated (non-grounded) thermocouples.

Pulse/PWM Output Specifications

ItemPulse OutputPWM Output
Output Points 4 points
Output Method PLS0 to PLS3
(OUT0 to OUT3)
defined by user
PWM0 to PWM3
(OUT0 to OUT3)
defined by user
Load Voltage DC24V
MIn. Load Current 1mA
Max. Output Frequency - 2.5kHz
Pulse Array Maximum Output Frequency 5kHz
(Total number of used channels)
-
Pulse Acceleration/ Deceleration Speed Available -

External Dimensions

Note: Panel thickness should be between 1.6 and 5.0 mm (0.06 to 0.02 in.), and should be based on the strength required to mount the LT to the panel.

LT Series External Dimensions LT Series Type H Side Panel