GP2301H-LG41-24V Specifications (End of sale: 2013/9/30)
Functional Specifications
Model (Global Code) | GP2301H-LG41-24V (PFXGP2301HLD) →Recommended Substitute | ||
---|---|---|---|
Type | Monochrome LCD | ||
Display Colors | Black and White (2 Shades)/ Black and White (8 Shades) (software control)*1 |
||
Backlight | CCFL (service life: 50,000 hourse or more at 24-hr operation) |
||
Resolution | 320 × 240 pixels | ||
Effective Display Area (mm) | 115.2(W) × 86.4(H) | ||
Brightness Control | 4 levels via touch panel | ||
Contrast Control | 8 levels of adjustment via touch panel | ||
Language Character Sets | ASCII: (Code page 850) Alphanumeric (incl. European characters) Chinese: (GB2312-80 codes) simplified Chinese fonts Japanese: ANK 158, Kanji : 6962 (JIS Standards 1 & 2) Korean: (KSC5601 - 1992 codes) Hangul fonts Taiwanese: (Big 5 codes) traditional Chinese fonts |
||
Text | 8 × 8 dots | 40 char. × 30 rows | |
8 × 16 dots | 40 char. × 15 rows | ||
16 × 16 dots | 20 char. × 15 rows | ||
32 × 32 dots | 10 char. × 7 rows | ||
Character Sizes*2 | 8 × 8 dots, 8 × 16 dots, 16 × 16 dots, 32 × 32 dots | ||
Font Sizes*3 | Width can be expanded 1 to 8 times. Height can be expanded 1/2, 1 to 8 times.*4 |
||
Application Memory | FLASH EPROM 1MB | ||
Data Backup Memory | SRAM128KB - Uses lithium battery*5 | ||
Touch Panel Resolution | 16 x 12 keys/ screen - 1 or 2 point touch | ||
Function Switches | 11 (DOUT Output: F1, F2) | ||
Operation Switch | Function Switch (O.P Key) (DOUT Output) | ||
Emergency Switch | Push-lock Switch Compliant Standard: ISO 13850, EN418, JIS B 9703, IEC 60947-5-1, EN60947-5-1, JIS C 8201-5-1, UL508 (Recognized), CSA C22.2 No.14 (Recognized) Applicable Standard*6: ISO 13849-1, EN954-1, JIS B 9705-1 |
||
3-position Enable Switch | GP2000H Rear-face Switch 3-Position Output Compliant Standard: IEC 60947-5-1, EN60947-5-1, JIS C 8201-5-1, ANSI/RIA R15.06-1999, UL508 (Recognized), CSA C22.2 No.14 (Recognized) Applicable Standard*6: ISO 13849-1, EN954-1, JIS B 9705-1 |
||
Interfaces | Serial Interface (COM1) |
Asynchronous Transmission Method: RS-232C/ RS-422, Data Length: 8/7 bits, Stop bit: 2/1bits, Parity: Odd or Even, Speed 2400bps to 115.2Kbps, 187.5Kbps*7 |
|
Tool Connector Interface |
Asynchronous TTL level nonprocedure command I/F Used for transferring data between the GP application software and the GP. Used for data transfer with the 2-Port feature. |
||
CF Card Interface | 1 Slot | ||
External Output | DOUT Output | 2-point (F1, F2) open collector output Rated voltage: DC24V Max. Rated current: 300mA/ point |
|
Operation Output | 1-point (F1, F2) open collector output Rated voltage: DC24V Max. Rated current: 300mA/ point |
||
Buzzer Output | 1-point (F1, F2) open collector output Rated voltage: DC24V Max. Rated current: 300mA/ point |
||
3-position Enable Switch Output |
2 Contacts (NO)*8, Rated voltage: DC24V Max. Rated current: 300mA (Applicable Load: 4mA DC24V min.) |
||
Emergency Switch Output |
2 Contacts (NC), Rated Voltage: DC30V Rated Current: 1A max. (Applicable Load: 1mA DC5V min.) Open Collector Output: 1 point Rated Voltage: DC 24V, Rated Current: 300mA max. |
- In order to set the monochrome (eight levels of gray) mode, GP-PRO/PBIII for Windows Ver. 6.2 or later is required. Depending on the color used, selecting MONOCHROME 8 HUES may cause the GP unit’s screen to flicker and make it difficult to distinguish colors.
- The display font will differ depending on which (language) character, or which size you select.
- When using GP-PRO/PBIII C-Package01 (GP-PRO/PBIII for Windows Ver. 6.0) or earlier, fonts can be scaled only 1,2,4, or 8 times.
- Only available when using "1/2 Byte Character" settings via software. (Only Japanese, Chinese, Taiwanese and Korean characters.)
- A Lithium battery's lifetime is:
10 years when the battery's ambient temperature is under 40℃
4.1 years when the battery's ambient temperature is under 50℃
1.5 years when the battery's ambient temperature is under 60℃
When used for backup:
Approximately 60 days, with a fully charged battery
Approximately 6 days, with a half-charged battery - Overall system may not meet these standards if implemented outside these parameters. Be sure to follow these standards when designing the system.
- SIEMENS SIMATIC S7-200/300/400 series (MPI port only). Please contact your Pro-face sales representative for supported models and other details.
- When GP-H70 Compatibility mode is selected, 1 Contact (NO).
General Specifications
Model (Global Code) | GP2301H-LG41-24V (PFXGP2301HLD) →Recommended Substitute | ||
---|---|---|---|
Electrical | Rated Voltage | DC24V | |
Rated Voltage Range | DC19.2 - 28.8V | ||
Power Consumption | 15W or less | ||
Allowable Voltage Interruption | 10ms or less | ||
Voltage Endurance | AC500V, 20mA for up to 1 minute (between charging and FG terminals) |
||
Insulation Resistance | 20MΩ or higher at DC500V (between charging and FG terminals) |
||
Environmental | Ambient Operating Temperature | 0 to 40℃ | |
Storage Temperature | -20 to 60℃ | ||
Ambient Humidity | 10 to 90% RH (non-condensing wetbulb temperature 39℃ or less) |
||
Storage Humidity | 10 to 90% RH (non-condensing wetbulb temperature 39℃ or less) |
||
Vibration Resistance | IEC61131-2 (JIS B 3502) compliant. When vibration is NOT continuous: 10 - 57Hz 0.075mm, 57 - 150Hz 9.8m/s2 When vibration is continuous: 10 - 57Hz 0.035mm, 57 - 150Hz 4.9m/s2 X,Y,Z directions for 10 times (80 min.) |
||
Shock Resistance | IEC61131-2 (JIS B 3502) compliant (147m/s2, X,Y,Z directions for 2 times) |
||
Dropping | IEC61131-2 (JIS B 3502) compliant (1.0m drop, twice) |
||
Noise Immunity | Noise Immunity: 1000Vp-p Pulse Duration: 1µs, Rise Time: 1ns (via noise simulator) |
||
Electrostatic Discharge Immunity | 6kV (complies with IEC 61000-4-2 Level 3) | ||
Corrosive Gasses | Free of corrosive gases | ||
Structural | Grounding | 100Ω or less, or your country's applicable standard | |
Protection | Equivalent to IP65f (JEM1030), NEMA#250 TYPE 4X/12*1 | ||
External Dimensions (mm) | 253W × 185H × 58D (excluding projections) | ||
Weight | 1.2kg (2.6lb) or less*2 | ||
Cooling Method | Natural air circulation |
- When using the CF Card Interface Guard Attachment Screws (included in the package).
- Not including the CF Card Interface Guard Attachment Screws or the Emergency Switch Guard.
Dimensions

* The GP-2401H is used for the Front diagram. This unit's display panel size and number of
function switches differ from those of the GP-2401H unit.