 "SAAA111 - 137 " Error Info

Error Code* Error Message Cause and Troubleshooting
0xC0B0006F
SAAA111
-1062207377
3232759919
Too many trigger conditions. The number must be within XX. (XX: Number) Please reduce the no. of trigger conditions, following the direction of the message.
0xC0B00071
SAAA113
-1062207375
3232759921
(Symbol Sheet: XX Group: XX) has too large total size of device data. Please divide the group. (XX Bytes or less) Please reduce the no. of group symbol data (array element count, member count, or data count of each member), following the direction of the message.
0xC0B00072
SAAA114
-1062207374
3232759922
Too many actions to register. Please reduce the no. of registered actions.
0xC0B00073
SAAA115
-1062207373
3232759923
Unsupported trigger condition is set for the node (XX) (A GP Series node has trigger-condition restrictions. For more details, please refer to the manual). (XX: NODE name) Please confirm the trigger condition, following the direction of the message. Please confirm the trigger condition, following the direction of the message.
0xC0B00074
SAAA116
-1062207372
3232759924
The trigger condition (XX) is for a GP Series node. Logic operation is not supported in this type of trigger condition. (XX: Trigger condition name)
0xC0B00075
SAAA117
-1062207371
3232759925
The structure of a sheet/group in the symbol sheet of (XX) is collapsed. Please create it again. (XX: ???) Please re-create the group symbol, following the direction of the message.
0xC0B00076
SAAA118
-1062207370
3232759926
No trigger condition exists in (XX). The trigger condition may have been deleted. Please check it again. (XX: ???) Please confirm those using the trigger condition (data transfer feature, action feature, etc.), following the direction of the message.
0xC0B00077
SAAA119
-1062207369
3232759927
The node specified in the trigger condition used in (XX) does not exist. The node may have been deleted. Please check it again. (XX: ???) Please confirm the trigger condition, following the direction of the message.
0xC0B00078
SAAA120
-1062207368
3232759928
The transfer-source constant value specified in data transfer (XX) has an error. (XX: Data transfer name) Please confirm that the constant value is proper for the data type.
0xC0B00080
SAAA128
-1062207360
3232759936
(Symbol Sheet: XX, Symbol: XX Address: XX and Address: XX) is invalid as a device address. Please confirm the settings of the symbol sheet, following the direction of the message.
0xC0B00081
SAAA129
-1062207359
3232759937
Because of the non-bit type symbol in the previous line, consecutive bit type is unavailable for (Symbol Sheet: XX, Symbol: XX, and Address: XX). Please check it again.
0xC0B00082
SAAA130
-1062207358
3232759938
Because of the bit type symbol in the previous line, consecutive non-bit type is unavailable for (Symbol Sheet: XX, Symbol: XX, and Address: XX). Please check it again. Please confirm the settings of the symbol sheet, following the direction of the message.
0xC0B00083
SAAA131
-1062207357
3232759939
Cannot specify consecutive from the previous line for (Symbol Sheet: XX Symbol: XX Address: XX). Please check whether it is within the device range.
0xC0B00084
SAAA132
-1062207356
3232759940
(Symbol Sheet: XX Symbol: XX Address: XX) is beyond the valid device range.
0xC0B00085
SAAA133
-1062207355
3232759941
(Symbol Sheet: XX Symbol: XX) does not have any valid symbols before. Cannot judge for which device the bit specification is.
0xC0B00086
SAAA134
-1062207354
3232759942
(Symbol Sheet: XX Group: XX) does not have any valid symbols. A group must have at least 1 symbol. Please confirm the settings of the symbol sheet, following the direction of the message.
0xC0B00087
SAAA135
-1062207353
3232759943
(Symbol Sheet: XX) has nonconsecutive symbols. Cannot set them in array.
0xC0B00088
SAAA136
-1062207352
3232759944
(Symbol Sheet: XX Array Group: XX) has too many devices to support. Please confirm the settings of the symbol sheet, following the direction of the message.

0xC0B00089
SAAA137
-1062207351
3232759945

(Symbol Sheet: XX Array Group: XX) is beyond the valid device range.

  * - 1st line: Error code
  2nd line: Integrated error code
  3rd line: Error code with decimal code
  4th line: Error code without decimal code

Back to page top <--Returns to the previous page