 "RYAA021 - 102 " Error Info

Error Code* Error Message Cause and Troubleshooting
0xC0AF0015
RYAA021
-1062273003
3232694293
The specified access type is illegal. A fatal error occurred. Please perform forced transfer of 'GP-Pro EX', and then execute transfer again.  
0xC0AF0016
RYAA022
-1062273002
3232694294
The specified data type is illegal.
0xC0AF0017
RYAA023
-1062273001
3232694295
The no. of data you specified is too many to write (Please reduce it to XX or fewer) (XX: Data number)
0xC0AF0018
RYAA024
-1062273000
3232694296
The operation result to write is below the lower limit value. Attempted to write an out of range value. Please change the setting to write an in-range value.
0xC0AF0019
RYAA025
-1062272999
3232694297
The operation result to write is beyond the upper limit value.
0xC0AF001A
RYAA026
-1062272998
3232694298
Could not send processing request to the network destination due to insufficient memory. Please close another application or restart the OS.
0xC0AF001B
RYAA027
-1062272997
3232694299
The specified group was not found. A fatal error occurred. Please perform forced transfer of 'GP-Pro EX', and then execute transfer again.  
0xC0AF001C
RYAA028
-1062272996
3232694300
The two compared access tickets differ in their nodes, equipment, or devices. A fatal error occurred. Please perform forced transfer of 'GP-Pro EX', and then execute transfer again.  
0xC0AF001D
RYAA029
-1062272995
3232694301
The specified access ticket is not for this node.
0xC0AF001E
RYAA030
-1062272994
3232694302
Could not register the cache because of insufficient memory. Please close another application or restart the OS.
0xC0AF0020
RYAA032
-1062272992
3232694304
The access ticket you tried to use in block access is not of the block type. A fatal error occurred. Please perform forced transfer of 'GP-Pro EX', and then execute transfer again.  
0xC0AF0021
RYAA033
-1062272991
3232694305
The small service to process was not found.
0xC0AF0022
RYAA034
-1062272990
3232694306
The size of block access to the device exceeded the limit. The max buffer size for Device Block Write/Read is 10KB. Please set a size less than that.
0xC0AF0025
RYAA037
-1062272987
3232694309
The no. of requests to Read/Write via network at a time exceeded the limit (XX). (XX: Device no.) Please recheck the settings of requests from 'Pro-Server EX' and 'GP-Pro EX' to the network destination, and redesign the system to limit the no. of requests to the max value.
0xC0AF0030
RYAA048
-1062272976
3232694320
Communication error occurred during communication with the destination node. Please confirm that the network connection to the node has been properly established. Please check whether the network cable between the local node and the destination node etc. is correctly connected.
0xC0AF0031
RYAA049
-1062272975
3232694321
The destination node did not responded within the specified time. Please confirm that the network connection to the node has been properly established. -
0xC0AF0032
RYAA050
-1062272974
3232694322
The destination node did not responded within the specified time. Please confirm that the network connection to the node has been properly established. -
0xC0AF0033
RYAA051
-1062272973
3232694323
Communication with the destination NODE stopped because of the change from online to offline, or to transfer mode. Please place GP3000 Series online.
0xC0AF0040
RYAA064
-1062272960
3232694336
Failed to read the device. The data may have been read into an illegal or undefined device address. Please specify a proper device address.
0xC0AF0041
RYAA065
-1062272959
3232694337
Failed to write the device. The data may have been written into an illegal or undefined device address. Please specify a proper device address.
0xC0AF0045
RYAA069
-1062272955
3232694341
The specified request is not supported. Please upgrade 'GP-Pro EX' to a supported version by transferring the system with 'GP-Pro EX'. Or the Node Type set in the 'Pro-Studio EX' Node Settings may be different from the actual model. Please confirm that the Node Type is properly set.
0xC0AF0046
RYAA070
-1062272954
3232694342
The specified request is not supported. Please upgrade 'GP-Pro EX' to a supported version by transferring the system with 'GP-Pro EX'.
0xC0AF0050
RYAA080
-1062272944
3232694352
The project ID of the network project file is different (A different NPJ is being used). Please transfer the network project file with 'Pro-Studio EX' again.
0xC0AF0051
RYAA081
-1062272943
3232694353
The network project file does not have necessary data.
0xC0AF0052
RYAA082
-1062272942
3232694354
The network project file is damaged. Please transfer the network project file with 'Pro-Studio EX' again. If it's not solved, after performing forced transfer of 'GP-Pro EX', please transfer the network project file with 'Pro-Studio EX' again.
0xC0AF0053
RYAA083
-1062272941
3232694355
The network project file does not exist.
0xC0AF0060
RYAA096
-1062272928
3232694368
Failed to transfer data to GP. Please confirm that the Device/PLC connected to the GP works properly. Or, please transfer the network project file with 'Pro-Studio EX' again.
0xC0AF0061
RYAA097
-1062272927
3232694369
Failed to read the device from GP. Accessed a read-protect area. Please change the settings to avoid this.
0xC0AF0062
RYAA098
-1062272926
3232694370
Failed to write the device to GP. Accessed a write-protect area. Please change the settings to avoid this.
0xC0AF0063
RYAA099
-1062272925
3232694371
In device access to GP, the device no. was out of range. An invalid device was specified. Attempted to access a nonexistent device.
0xC0AF0064
RYAA100
-1062272924
3232694372
Failed to transfer data to GP. (The destination NODE does not respond.) The Destination Node does not respond. Please check the followings:
 -The network cable is properly connected
 -The destination node is ON, and
 -The IP address in the Node Setting of 'Pro-Studio EX' is correct.
Or, please transfer the network project file with 'Pro-Studio EX' again.
0xC0AF0065
RYAA101
-1062272923
3232694373
Failed to read the device from GP. (The destination NODE does not respond.) The Destination Node does not respond. Please check the followings:
 -The network cable is properly connected
 -The destination node is ON, and
 -The IP address in the Node Setting of 'Pro-Studio EX' is correct.
0xC0AF0066
RYAA102
-1062272922
3232694374
Failed to write the device to GP. (The destination NODE does not respond.)

  * - 1st line: Error code
  2nd line: Integrated error code
  3rd line: Error code with decimal code
  4th line: Error code without decimal code