Compatibility
|
|
 |
Compatibility of Extended SIO Script
|
 |
|
GP-PRO/PB3's [Extended SIO Script] is converted to GP-Pro EX’s [Extended Script] in the [Script Settings].
The contents of the [Extended SIO Script] are converted as they are. However, the Extended SIO Script's assignment to COM ports may vary or may be cancelled after conversion depending on the configuration of the COM ports. Select your interface pattern set with GP-PRO/PB3 and refer to its conversion pattern.
|
Interface setting pattern table when using the GP2000 series’ Extended SIO Script |
COM1 |
COM2 |
LAN Interface |
Conversion Pattern |
PLC (RS-232C) *1 |
Extended SIO Script (RS-232C) |
Unused |
Pattern1 |
PLC (RS-422) *1 |
Extended SIO Script (RS-232C) |
Unused |
Pattern2 |
Extended SIO Script (RS-422) |
PLC (RS-232C) *1 |
Unused |
Pattern3 |
Unused |
Extended SIO Script (RS-232C) |
PLC |
Pattern4 |
Extended SIO Script (RS-422) |
Unused |
PLC |
Pattern5 |
*1:
|
indicates that a PLC type is selected. Temperature controllers, inverters are included.
|
|
|
Reference:
The interface, on the GP3000 series, compatible with RS-232C is COM1. If the Extended SIO Script cannot be assigned to the COM1 of RS-232C, the assignment is cancelled. For reference, the table of COM1 port of the GP series is shown below.
|
|
COM1 |
COM2 |
GP3**0 series |
RS-232C/485 (422) |
RS-485 (422) |
GP3302B |
RS-232C |
RS-485 (422) |
GP3200 series |
RS-232C/485 (422) |
- |
|
The GP3**0 series includes GP3750, GP3600, GP3500, GP3400, and GP3300.
|
Conversion Pattern
|
After conversion, the PLC type will be assigned to the COM1 port and the assignment of the Extended SIO Script will be canceled.
GP-PRO/PB3
|
Interface |
COM1 |
COM2 |
LAN |
Communication type |
RS-232C |
RS-232C |
- |
Usage |
PLC protocol |
Extended SIO Script |
- |
|
|
|
GP-Pro EX
|
Interface |
COM1 |
COM2 |
LAN |
Communication type |
RS-232C |
RS-422/485 |
- |
Usage |
PLC protocol |
- *2 |
- |
|
(- Unused/Unsupported)
|
|
*2:
|
For the same use as before, re-assign the [Extended Script] to COM2 in GP-Pro EX’s [System Settings Window] → [Peripheral Settings] → [Script Settings]. For the RS-232C connection on the COM2 port, however, conversion of RS-232C/422 is required. For more information, contact the nearest Pro-face office.
|
|
|
After conversion, the PLC type will be assigned to the COM1 port and the assignment of the Extended SIO Script will be canceled.
GP-PRO/PB3
|
Interface |
COM1 |
COM2 |
LAN |
Communication type |
RS-422 |
RS-232C |
- |
Usage |
PLC protocol |
Extended SIO Script |
- |
|
|
|
GP-Pro EX
|
Interface |
COM1 |
COM2 |
LAN |
Communication type |
RS-422 |
RS-422/485 |
- |
Usage |
PLC protocol |
- *3 |
- |
|
(- Unused/Unsupported)
|
|
*3:
|
For the same use as before, re-assign the [Extended Script] to COM2 in GP-Pro EX’s [System Settings Window] → [Peripheral Settings] → [Script Settings]. For the RS-232C connection on the COM2 port, however, conversion of RS-232C/422 is required. For more information, contact the nearest Pro-face office.
|
|
|
After conversion, the PLC type set to COM2 will be assigned to COM1 and the assignment of the Extended SIO Script will be canceled.
GP-PRO/PB3
|
Interface |
COM1 |
COM2 |
LAN |
Communication type |
RS-422C |
RS-232C |
- |
Usage |
Extended SIO Script |
PLC protocol |
- |
|
|
|
GP-Pro EX
|
Interface |
COM1 |
COM2 |
LAN |
Communication type |
RS-232C |
- |
- |
Usage |
PLC protocol |
- *4 |
- |
|
(- Unused/Unsupported)
|
|
*4:
|
For the same use as before, re-assign the [Extended Script] to COM2 in GP-Pro EX’s [System Settings Window] → [Peripheral Settings] → [Script Settings]. Conversion on the COM2 port of RS-232C422 is required. For more information, contact the nearest Pro-face office.
|
|
|
After conversion, the [Extended SIO Script] set in COM2 will be assigned to COM1. Any change of settings is unnecessary.
GP-PRO/PB3
|
Interface |
COM1 |
COM2 |
LAN |
Communication type |
- |
RS-232C |
10BASE-T |
Usage |
- |
Extended SIO Script |
PLC protocol |
|
|
|
GP-Pro EX
|
Interface |
COM1 |
COM2 |
LAN |
Communication type |
RS-232C |
- |
10BASE-T |
Usage |
Extended SIO Script |
- |
PLC protocol |
|
(- Unused/Unsupported)
|
|
|
After conversion, the assignment of the [Extended SIO Script] will be cancelled.
GP-PRO/PB3
|
Interface |
COM1 |
COM2 |
LAN |
Communication type |
RS-422C |
- |
10BASE-T |
Usage |
Extended SIO Script |
- |
PLC protocol |
|
|
|
GP-Pro EX
|
Interface |
COM1 |
COM2 |
LAN |
Communication type |
- |
- |
10BASE-T |
Usage |
- *5 |
- |
PLC protocol |
|
(- Unused/Unsupported)
|
|
*5:
|
For the same use as before, re-assign the [Extended Script] to COM2 in GP-Pro EX’s [System Settings Window] → [Peripheral Settings] → [Script Settings]. Rewiring is also required because the pinout of the COM1 is different. For more information, contact the nearest Pro-face office.
|
|
|
|
|
|