The compatibility of GP-PRO/PB3 and GP-Pro EX is as shown below.
For the conversion with restrictions, refer to the important notes described later.
There are the alarm editor (contents of messages) and the alarm tags (parts).
■ Compatibility of the alarm editor |
GP-PRO/PB3's [Basic Alarm Settings] is converted to GP-Pro EX's [Alarm Settings].
Basically, the operation of GP-Pro EX's [Alarm Settings] is the same as that of GP-PRO/PB3's [Basic Alarm Settings].
Alarm's features of GP-PRO/PB3 and GP-Pro EX
GP-PRO/PB3
|
GP-Pro EX
|
Remark
|
Message |
[Enable Banner] of [Alarm Settings] |
*1
|
Summary |
[Enable Summary] of [Alarm Settings] |
-
|
Bit Alarm Log |
[Bit Monitoring] of Block 1 in [Alarm Settings] |
-
|
Word Alarm Log |
[Word Monitoring] of Block 1 in [Alarm Settings] |
-
|
NOTE |
*1 |
With GP-PRO/PB3, the maximum number of alarm messages is 512, however, actually more than 512 alarm messages can be input in GP-PRO/PB3. (* Operation is disabled after transfer)
If you convert a project file with more than 512 alarm messages to GP-Pro EX data, 512 messages can be converted, but the 513th message and after cannot be converted.
|
|
■ Compatibility of the alarm tags (parts) |
GP-PRO/PB3's alarm tags (parts) are converted to GP-Pro EX's [Alarm] part.
Basically, the operation of GP-Pro EX's [Alarm] is the same as that of GP-PRO/PB3's alarm tags.
Alarm's features of GP-PRO/PB3 and GP-Pro EX
GP-PRO/PB3
|
GP-Pro EX
|
Remark
|
Q tag |
[History] of [Alarm] |
*2
|
a tag (alarm part) |
[Summary] of [Alarm] |
-
|
NOTE |
*2 |
Even if you have not set any block in the [Q tag] settings in GP-PRO/PB3, it will be also automatically converted to [Block Settings] of GP-Pro EX.
The operation is the same.
|
|
|