 Is it possible to use Connection Device Address on Logic Screen?

Yes, it is possible to use a connection device address on the logic screen. There are 2 methods to setup as below.

-
How to use Connection Device Address directly
1.
Click the icon of a numberic keypad after inputting instruction.




2.
A keypad for inputting addresses will be displayed. Input a connection device address.




3. The connection device address will be set on the instruction.



MEMO
Please refer to the maximum number of registration in case of using connection device addresses on the logic program.
Bit Address
256
Word Address
256
H System Variable
64
Total
256

*
There are the maximum number of each items and of total.

-

Registering Connection Device Address

1.
Select the [Common Settings] menu, and click [Symbol Variable Settins].




2.
[Edit Symbol Variable] will be displayed.@Set the specified name on [Name], the bit address or the word address on [Type], and click the icon of the keypad on [Address] to input the connection device address.




3.
After inputting the instruction, click the pull-down icon. The symbol which you have set will be displayed.




4.
Symbol (Connection Device Address) will be set on the instruction.




MEMO
The maximum number of Symbols which can be registered is 3000.



Back to page top Return to the previous page