Error Messages displayed with WinGP |
 |

|
|
Error messages displayed with WinGP are as below.
|
|
Error Message
|
Cause and Solution
|
Unable to load file [RootFrame.dll]
|
If the RootFrame.dll file is damaged or does not exist, this error message appears. In this case, re-install WinGP. |
This application has failed to start because ****.dll was not found. Re-installing the application may fix this problem.
|
If the WinGP system configuration file is damaged or does not exist, this error message appears. In this case, re-install WinGP. |
[.ini] initialization file is missing. Startup will use default values.
|
If the PCRuntime.ini file is damaged or does not exist, this error message appears. In this case, the system will start after all IPC settings are reset to the initial settings. |
Startup canceled because of error.
|
If an error occurs for an unexpected reason during startup, this error message appears. |
Display unit does not support WinGP. Application will end.
|
If WinGP is started under an incompatible installation environment, this popup message appears. Install WinGP onto a compatible model. |
Cannot continue because the install path exceed 200 characters.
|
If the WinGP installation folder is in a low-level directory or the pathname is too long, this error message appears. Uninstall WinGP once, and the re-install it in a directory whose pathname is within 200 characters. |
Unable to use the WinGP API communication function, which requires installation of either the WinGP SDK or Pro-Server EX. Please confirm one of these is installed.
|
If the API communication is enabled, and WinGP SDK has not been installed, this error message appears. In this case, re-install WinGP or install Pro-Server EX.
|
|
|
Error messages displayed with Project Copy (Copy Tool) are as below.
|
|
Error Message
|
Cause and Solution
|
Project Display Unit Setting: *****. Connected Display Unit: PS-*****. Change display unit in the project settings and then run transfer operation.
|
If the model specified in a project does not match with the model of the copy destination, this error message appears. In this case, change the model specified in the project before executing the copy operation.
|
Select Project.
|
If you try to execute the copy operation without selecting a project file, this error message appears. Before executing the copy operation, select a project file.
|
Project does not exist.
|
If you select a project file that does not exist, this error message appears. Check if the project file exists, and select a project file again.
|
Copy destination not found.
|
If the folder for storing a project file is not located in the specified directory, this error message appears. The WinGP folder configuration may have been changed for some reason. Re-install the WinGP folder.
|
Copying failed.
|
If the system failed in copy operation for any reason, this error message appears.
|
Unable to copy as connected devices/PLCs are different.
|
If the type of connection device specified in a project to copy does not match with the connection device driver of WinGP, this error message appears. Before copying the project, change the type of the connection device, or transfer the project by using a transfer tool.
|
Unable to copy as WinGP is running.
|
If you try to execute the copy operation when WinGP is active, this error message appears. Close WinGP first, and then execute the copy operation.
|
CF card folder as defined in project not found. Select a CF card folder.
|
If you try to copy a project that enables use of a CF card file, and the CF card folder specified in the project cannot be referred to from the copy tool, this error message appears. In the dialog displayed after this message, specify the folder for storing a target file.
|
This project is open or has errors in the Model Settings. Please edit and save the project again.
|
If you try to copy a project that raises an error message about a transfer failure when saving the project with GP-Pro EX, this error message appears. Re-edit the project with the GP-Pro EX.
|
|
|
|