GP-Pro EX Device/PLC Connection Manual
Please see below for required drivers and the system requirements to use the pass-through function.
Please refer to [Pass-Through Function Guide] for installation or settings of the pass-through function.
When using the Pass-Through Function by SIMATIC S7 MPI Direct Driver, please refer to [SIMATIC S7 MPI Direct Driver Pass-Through Function Guide].
For details about how to connect to the Display, click the hyperlink in the Driver column to open the manual PDF (portable document format) file for that driver.
Maker |
Driver |
System Requirements |
---|---|---|
Mitsubishi Electric Corporation |
The following GPP function software packages are required.
|
|
YASKAWA Electric Corporation |
The following engineering tool is required. MPE720 Ver5.38 / Ver6.04 or higher |
|
Yokogawa Electric Corporation |
The following programming tool is required. WideField2 R3.01 or higher Pass-Through Function can be used only when the display is connected to the programming port on the CPU. |
|
The following programming tool is required. WideField2 R3.01 or higher |
||
OMRON Corporation |
The following programming support tool is required. CX-Programmer Version 3.00 or higher ![]() To use Pass-Through Function, [SYSMAC WAY] needs to be specified for [Network Type] in the ladder software. |
|
The following programming support tool is required. CX-Programmer Version 3.00 or higher ![]() - If High Performance Unit is written by the Pass Through Function, response of Link Unit temporarily stops and an error may be displayed on the Display. - To use Pass-Through Function, [SYSMAC WAY] needs to be specified for [Network Type] in the ladder software. - The following CPU unit does not support the Pass-Through Function. CJ2H-CPU68-EIP CJ2H-CPU67-EIP CJ2H-CPU66-EIP CJ2H-CPU65-EIP CJ2H-CPU64-EIP CJ2M-CPU35 CJ2M-CPU34 CJ2M-CPU33 CJ2M-CPU32 CJ2M-CPU31 |
||
Rockwell Automation, Inc. |
The following programming support tools are required.
|
|
Siemens AG |
The following programming tools are required.
|
|
KEYENCE Corporation |
The following ladder support software is required.
![]() During [Transfer to PLC] and [Read from PLC] on the Ladder Support Software, the communications with the Display may be temporarily interrupted. |
|
Panasonic Electric Works SUNX Co.,Ltd. |
The following programming tool software is required. Control FPWIN GR Ver.2.30 or higher ![]() - When using Pass-Through function, it is necessary to connect Display to Tool port of the control unit. - “C-NET (RS232C)” needs to be selected for [Network type] in the [Communication Settings]. - “Station home” or “C-NET” needs to be selected for [Network selection] in the [Specify Station No.]. However, select “C-NET” when you use Control FPWIN GR Ver. 2.30. - During [Upload from PLC] and [Download to PLC] on the Programming Tool Software, the communications with the Display may be temporarily interrupted. |
|
TOSHIBA MACHINE CO.,LTD. |
The following programming software is required. TCPRGOS-W Ver.2.27 or higher ![]() In the 1:n connection, the Eternal Device to be connected with is specified using the programming software. For a Pass-Through configuration tool, specify the External Device directly to be connected. |