If the GP-Viewer EX installation path is longer than 80 single-byte characters, an error message displays indicating GP-Viewer EX cannot start because its install path is too long. Please reinstall GP-Viewer EX to an installation path less than 80 single-byte characters.
You cannot install different versions of GP-Viewer EX on one computer.
If you input the wrong key code, the key code will not be set. Input the correct key code.
If you do not input key codes, the GP-Viewer EX trial version starts up.
When connecting to the display unit without setting up key codes in GP-Viewer EX, the GP-Viewer EX trial version starts up.
Up to three units of GP-Viewer EX can access the display unit at the same time. However, depending on the load, the display unit may not support three GP-Viewer connections. Please wait and try again. If you cannot connect on several attempts, consider looking at the design of the system.
Regardless of the number of connected display units, you can display up to four windows of GP-Viewer EX on one computer.
When starting GP-Viewer EX or clicking the update button, the display unit and GP-Viewer EX display the same alarm information. Subsequent alarm summary displays may differ between the two, because the display unit and GP-Viewer EX monitor the alarm information independently, depending on their communication speeds
Because the display unit's external storage and GP-Viewer EX's virtual external storage are not directly synchronized, GP-Viewer EX cannot save alarm information.
When the sampling frequency is short, or the timing for turning ON sampling's [Full Bit Address] is shorter than the timing for refreshing GP-Viewer EX, the GP-Viewer EX screen and display unit screen will be different because the system is unable to get the XY Historical Scatter Graph's show/hide information in time.
For errors that are automatically restored, such as communication errors with a connected device/PLC, the display unit may erase the error but the error remains in GP-Viewer EX. To remove the error, either change screens or click the Close button [x] in the system menu.
When multiple errors are triggered at the same time, depending on the timing of when errors are received, all the errors may not display.
As the screen does not rotate, the display unit does not support portrait orientation.
Because a computer and display unit have different file systems, files on external storage are read in different orders. Therefore, the file listing feature displays the files in a different order than a computer.
When using symbol variables with a bit address type, symbol variables with any element number other than 0 will result in an error on GP-Viewer EX.
When writing to the following addresses in GP-Viewer EX, the value is written to GP-Viewer EX's #H_ChangeScreenNo system variable, regardless of the screen mode.
[#INTERNAL]LS0008 (Direct Access Method)
[#MEMLINK]0015 (Memory Link Method)
System Data Area's [Change-To Screen] address
In synchronous mode, GP-Viewer EX writes to and reads from the display unit address. However, writes to and reads from GP-Viewer EX addresses for system variables and clock data.
In asynchronous mode, GP-Viewer EX writes to and reads from GP-Viewer EX addresses. However, writes to and reads from the display unit for the following addresses.
In the [System Settings] window's [Device/PLC] page, when Indirect Devices are set up, internal device addresses (LS area/USR area) other than the [Device ID Address]
Device/PLC addresses other than the System Data Area's [Change-To Screen] address
In Asynchronous Mode, instead of using internal devices*1, control the Global Window using system variables*2.
A.2.2.2 Word Type - #H System Variables
In Asynchronous Mode, instead of using internal devices*3, control the screen changes using a system variable (#H_ChangeScreenNo) or a switch’s [Change Screen] feature.
A.2.2.2 Word Type - #H System Variables
10.15.3 Change Screen Switch
*3 Internal Device Address (LS0008), System Data Area (0015) in the Memory link area
If you search for a display unit (server) from Pro-face Remote HMI, as its search result, Pro-face Remote HMI displays the IP address of the detected display unit. If the display unit (server) has more than one LAN port, the IP address of one of the multiple Ethernet settings is displayed. As a result, an IP address that is different from the actual IP address Pro-face Remote HMI communicates with may be displayed.
You can use the system variables below when the [Use Gateway Mode] check box is selected. Regardless of the Synchronous/Asynchonous settings in GP-Viewer EX, these are always synchronized.
#H_GW_AnalyzeModeFlag, #H_GW_SaveConfigCompletion, #H_GW_SaveConfigTrigger
A.2.2.1 Bit Type - #H System Variables
#H_GW_AverageInterruptTime, #H_GW_DivideInterruptSize, #H_GW_InterruptFrequency, #H_GW_MaximumInterruptTime
A.2.2.2 Word Type - #H System Variables