Products
Download
Contact us
Back to Top
 PS Series
 > PS Series Type-B  > PS-2000B RAS/System Monitor Update Module

Please acknowledge the following terms of use before you use our download service. Download of any file signifies your agreement to the terms of use.

Terms of Use
  1. Schneider Electric Japan Holdings Ltd. ("SEJH") shall retain all intellectual property rights to the files that SEJH provides for this service.
  2. Who, uses or plans to use SEJH's products, may download and use any file.
  3. Reproduction, disclosure, re-publication, assignment, lease, decompilation, modification, falsification or reuse of any file that SEJH provides for this service shall be prohibited.
    However, for manuals, samples, BMP images and CAD files, you may reprint, duplicate, quote a part of the content or the whole on your company's specification sheets, or instruction manuals for built-in products. Also you may change the layout of the content.
  4. This download service is provided through the Internet. Please acknowledge that SEJH provides no guarantee of the condition at the time of provision, the availability of access and the condition of use concerning this service before you use this service.
  5. Please use this service at your own risk.
  6. If any additional conditions such as service usage conditions are attached to the downloaded files, please comply with such conditions as well.
Notices:
  1. Files are subject to deletion, or modification of the contents or specifications without notice.
  2. Please confirm that the downloading file size completely accords with the download file size shown.
  3. If the file sizes do not match, delete the file without decompressing and then download the same file once again.
 Download
Note:
- To use this update, the previous version of the system monitor must be installed.
- This file is only for PS-2000B Series. Please do not use it for other models.
- If the System Monitor has already been registered in the start-up menu, the error message of a double start is displayed at OS start. In that case, please delete System Monitor registered in the start-up menu.

File Name PS2000B_SysmonUpdate20051206.exe
File Size 1,945KB
Unit Name PS-Series Type-B PS-2000B
OS Windows®2000, Windows®XP
Description Contains the RAS/System Monitor update.
Update Description
1. The following issues heve been corrected:
 
- Increases in memory usage of the System Monitor increases.
- The Power Option in the control panel could not be set when using the System Monitor for a long time with SoftMirror.
- The processing of System Monitor stopped while displaying a message of remote RAS communication error.
- When there were two or more network devices, it becomes Auto even if the first device was selected by setting of remote RAS.
- When starting System Monitor Propenty again, error action of WDT could be set even if Reset was enabled.
2. Restrictions:
 
- Administrator Authentication is required for executing SMART Monitoring.
- Only hard disks connected with IDE can be monitored by SMART.
The state of a hard disk connected with USB or SCSI cannot be monitored.
- CF cards do not support SMART and therefore the status of CF cards cannot be monitored.
- When PL-SM900 (softmirror utility) Rev.C or earlier is used, SMART cannot be monitored.
In this case, please download and install the PL-SM900 update module.
- Proper function of SMART Monitoring can not be guaranteed with a hard disk from any manufacturer other than Digital.
3. The version of this update PSB_SMON.EXE 1.07→ 1.08.
  If the version of PSB_SMON.EXE is 1.08 or higher, it is not necessary to execute this update.
The file exists in the C:\Proface\Sysmon folder.
Version information can be checked by referring to the version in file properties.


About RAS/System Monitor
For details, please read the following PDF:Manual PDF (3,944KB)


Installation (This file is self-extracting.)
1. Downloading "PS2000B_SysmonUpdate20051206.exe"
Click on "PS2000BSysmonUpdate20050222.exe"and download the data to the desired folder on your PC.
 
* If the update module cannot be downloaded to the PS-2000B unit, please download temporarily to the another PC, and copy the module to the PS-2000B unit where you want to install the module.
2. Exit System Monitor if it is running.
3. Double-click the downloaded file "PS2000B_SysmonUpdate20051206.exe".
4. Update starts automatically.
5. Reboot the system after installation.

Update History
[January 26, 2006]
1. The following issues were corrected:
 
- Increases in memory usage of the System Monitor increases.
- The Power Option in the control panel could not be set when using the System Monitor for a long time with SoftMirror.
- The processing of System Monitor stopped while displaying a message of remote RAS communication error.
- When there were two or more network devices, it becomes Auto even if the first device was selected by setting of remote RAS.
- When starting System Monitor Propenty again, error action of WDT could be set even if Reset was enabled.
2. With this update, applications with the following version are provided.
 
- PSB_SMON.EXE Ver.1.07 --> 1.08
[October 11, 2005]
1. The following issues were corrected:
 
- When System Monitor started in Windows(R)XP, the icon was not registered in the task tray.
2. The following settings were added:
 
- An error pop up message displayed again.
- The text of the error pop up message was changed to red.
- The SMART monitoring function support latest HDD.
3. With this update, applications with the following version are provided.
 
- PSB_SMON.EXE Ver.1.05 --> 1.07

[February 22, 2005]

1. The following settings were added:
 
- Hard Disk is monitored by Hard Disk SMART function.
- System Monitor is set to start automatically when OS starts.
2. This update will make the version of PSB_SMON.EXE 1.04→1.05.
[October 15, 2004]
1. The following issues were corrected:
 
- The general signal input (Din) in the RAS port can occasionally be falsely detected.
2. With this update, file versions changes as follows.
 
- PSSYSMON.sys Ver.1.04 --> 1.05
[June 2, 2004]
1. The following issues were corrected:
 
- The System Monitor could not sometimes start even if registered in the Startup file.
- If a messages was edited and cancelled with System Monitor Property, a verification dialog box was not displayed.
2. The following settings were added:
 
- Compatibility with Soft Mirror Utility.
3. With this update, file versions changes as follows.
 
- PSB_IOC.DLL Ver.1.00→1.02
 

Last Updated: January 26, 2006
| Return to Top | | Back | HOME |
FAQ for use | Protection of Personal Information | Trademark Acknowledgments | About Intellectual Property Rights | Terms of Use
Copyright (C) 2005- Schneider Electric Japan Holdings Ltd. All Rights Reserved.