1.5.6.2 GP-4100 Series

O: Supported

X: Not supported

 

GP-4100 Series

 

GP-4105/

GP-4106/

GP-4107

GP-4104

Display Unit

 

 

 

Screen Area (in bytes)

6.5 Font Settings Guide

2.2 M

2.2 M

Portrait Installation

3.8.1.1 New - Display Unit and Model Settings

Function Expansion Memory

5.4.7 System Settings [Display Unit] - [Extended] Settings Guide

×

×

Installing the USB/RS-422/485 Conversion Adapters

×

×

MAC Address Display

M.16.2.7 Main Unit - Ethernet settings

×

External Storage

 

 

 

CF Card

5.7 Usable External Storage

×

×

SD Card

×

×

USB storage

*1

*1

FTP server

×

×

System Settings

 

 

 

Drawing in 256 colors

1.6 Supported Colors

×

×

Reverse Display

5.4.2 System Settings [Display Unit] - [Display] Settings Guide

Faded Color Blink

5.4.2 System Settings [Display Unit] - [Display] Settings Guide

×

×

Synchronize Text Display Language with Text Table

5.4.2 System Settings [Display Unit] - [Display] Settings Guide

×

×

Detect Backlight Burnout

5.4.3 System Settings [Display Unit] - [Operation] Settings Guide

×

×

Dimming Settings

5.4.2.1 Display Unit [Display] - Screen Settings

×

×

Two-Point Touch

5.4.3 System Settings [Display Unit] - [Operation] Settings Guide

×

×

Display the SD/USB Removal Icon

5.3 Safely detaching the SD Card or USB Storage Device

5.4.4.4 Display Unit [Mode] - Memory Card Settings

×

×

Screen Capture

40.6 Saving the Current Screen At Runtime (Screen Capture)

×

×

SRAM Auto Backup

5.4.4.4 Display Unit [Mode] - Memory Card Settings

×

×

Image Font

6.3 Image Font

Bitmap Font

6.4 Bitmap Font

Standard Font

5.4.7 System Settings [Display Unit] - [Extended] Settings Guide

×

×

Device/PLC Communication*2

 

 

 

Number of Devices/PLCs that can communicate simultaneously

7.2 Connecting to Multiple Devices/PLCs

1

1 *3

Specify Indirect Device

7.9.1 System Settings [Device/PLC] Settings Guide

Import Device/PLC tags

7.8 Using Device/PLC Tags

×

×

Ethernet Multilink

7.6 Connecting Multiple Display Units to One Device/PLC (Ethernet Multilink)

×

Device Monitor

40.4 Monitoring the Value of Device Addresses (Device Monitor)

Ladder Monitor

"PLC Ladder Monitor Operation Manual"

×

×

Transfer

 

 

 

Network Transfer

34.3 Transferring Project Files via Ethernet (LAN)

×

Modem Transfer

34.9 Updating Remote Screen Data via Modem

×

×

SIO Transfer (COM Connection)

34.12.1.1 Transfer Settings

×

×

Memory loader feature

34.8 Transferring Project Files Using a CF Card or USB Storage

CF/SD Card Connection

34.6 Transferring Just Data to a CF/SD Card

×

×

Common

 

 

 

Change Backlight Color (2)

5.5.2 Common - Backlight Color Settings

×

×

Clock Update Settings

5.5.1 Common - Clock Update Settings

Start Screen Settings

5.5.3 Common Settings - Start Screen Settings

Date format on CSV file output

20.12.1.1 Alarm Guide

25.9.4 Display/Save in CSV

×

×

Divide destination folder into files

5.7.1 Save in Folder and File Name

×

×

Increase Alarm Type settings and Text Table index

20.12.1 Common Settings (Alarm) Settings Guide

18.7.1.1 Text Table

×

×

Alarm Message Multiple Line Display

20.12.1.1 Alarm Guide

×

×

Append Value to Operation Log

23.10.2 Operation Log Settings

×

×

Change Password at Runtime

23.8 Editing Passwords Online

×

×

Indirectly specify Sampling Frequency and Alarm Settings

25.9.3 Mode

25.9.4.3 Display/Save in CSV/Data Settings - Alarm

×

×

Sampling data/Enhanced recipe data format co-exist

25.6 Collecting, Searching, and Sorting Various Data

×

×

Create a recipe (CSV data) index file at runtime

A.2.2.2 Integer Type - #H System Variables

×

×

Enhanced Recipes

26.18 Enhanced Recipe Data Flow

×

×

Extended Script copy file function

22.11.6 File Operation

×

×

Movie record/play feature

28.3 Recording Video

×

×

Use image unit

28.6 Displaying Multiple Video Camera Outputs Simultaneously

×

×

Sound Output Feature

27.1 Settings Menu

×

×

AUX

27.4 Triggering a Buzzer Sound from the Display Unit

×

×

Retentive Variables Function

8.14.5 Common Settings (Symbol Variables) Settings Guide

×

×

Registration of Fingerprint Data

23.9 Logging in with Fingerprint Recognition

×

×

Parts

 

 

 

Selector List

10.16 Selector List Parts Settings Guide

×

×

XY Scatter Graph

19.9 Displaying Sampled Data in a Scatter Graph

19.11 Displaying Current Values of Multiple Addresses All at Once in a Scatter Graph

×

×

Picture Display [CF Image Display]/[SD Image Display] for showing JPEG files

9.6.4 CF Image Display/SD Image Display

×

×

Alarm - Indirectly specify a block

20.12.2.1 Show History - Basic Settings/Basic

×

×

Special Data Display [File Manager] default path and sort method

26.9.3.2 File Manager - Extended

×

×

Special Data Display Part [File Manager] copy file to FTP

26.9.3.1 File Manager - Basic

×

×

Message Display's Bulletin Message

17.5 Displaying the Same Message on Multiple Display Units (Bulletin Messages)

×

×

Image Sensor Display

28.9 Displaying Video Images of Image Sensor

×

×

Animation

21.1 Animation - General

Alarm History Message Flow Display

20.12.2.6 Show History - Display

Alarm History/Sampling Data/Enhanced Recipe Data Refine Search/Sort Function

20.10 Searching / Sorting Alarm History

25.6 Collecting, Searching, and Sorting Various Data

26.22 Searching and Sorting Enhanced Recipe Data

×

×

Alarm Analysis Function

20.11 Alarm Analysis for Operation Log and Sampling

×

×

Logic

 

 

 

Logic Program Operation

30.2.1 Using Logic

×

×

I/O Driver

31.1 Controlling External I/O

×

×

Function Block

30.8 Function Block (FB)

×

×

Network

 

 

 

Remote PC Access

36.1.1 Remote PC Access (RPA)

×

×

GP-Viewer EX

37.1.1 GP-Viewer EX

×

×

Web Server

37.7.1 Web Server

×

×

Camera-Viewer EX

37.15.1 Camera-Viewer EX

×

×

GP Remote Printer Server

35.3.4 Procedure - Printing to a Network Printer

×

×

Input Equipment

 

 

 

USB Keyboard

16.3 Display USB Keyboard Inputs16.3
Display Inputs from USB Keyboard/EZ Numpad

×

×

EZ Illuminated Switch

16.4 Monitoring/Operating Alarm with EZ Illuminated Switch

×

×

EZ Numpad

16.3 Display Inputs from USB Keyboard/EZ Numpad

16.5 Setting Up Functions on the EZ Numpad

×

×

*1 Use it for screen transfer and saving sampling data to CSV only.

*2 Depends on the type of connected PLC/Device.

*3 When using the Ether multilink function, you can connect up to 2 devices/PLCs.