GP-4400 Series  | 
		GP-4401WW  | 
		GP-4401T  | 
		
  | 
	
|---|---|---|---|
Display Unit  | 
		
  | 
	||
Screen Area (Unit: byte)  | 
		16M  | 
		32M  | 
		|
Portrait Installation  | 
		
  | 
		
  | 
		|
Function Expansion Memory  | 
		-  | 
		-  | 
		5.4.7 System Settings [Display Unit] - [Extended] Settings Guide  | 
	
Installing the USB/RS-422/485 Conversion Adapters  | 
		
  | 
		
  | 
		|
MAC Address Display  | 
		
  | 
		
  | 
		|
External Storage  | 
		
  | 
	||
CF Card  | 
		-  | 
		-  | 
		|
SD Card  | 
		
  | 
		
  | 
		
	|
CFast Card  | 
		-  | 
		-  | 
		
	|
USB storage  | 
		
  | 
		
  | 
		
	|
FTP server  | 
		
  | 
		
  | 
		
	|
System Settings  | 
		
  | 
	||
Drawing in 256 colors  | 
		
  | 
		
  | 
		|
Reverse Display  | 
		
  | 
		
  | 
		5.4.2 System Settings [Display Unit] - [Display] Settings Guide  | 
	
Faded Color Blink  | 
		
  | 
		
  | 
		5.4.2 System Settings [Display Unit] - [Display] Settings Guide  | 
	
Synchronize Text Display with Text Table  | 
		
  | 
		
  | 
		5.4.2 System Settings [Display Unit] - [Display] Settings Guide  | 
	
Time Zone Settings  | 
		-  | 
		-  | 
		5.4.2 System Settings [Display Unit] - [Display] Settings Guide  | 
	
Detect Backlight Burnout  | 
		-  | 
		-  | 
		5.4.3 System Settings [Display Unit] - [Operation] Settings Guide  | 
	
Dimmer settings  | 
		
  | 
		||
2 point touch / Multitouch  | 
		-  | 
		-  | 
		5.4.3 System Settings [Display Unit] - [Operation] Settings Guide  | 
	
Display the SD/USB Removal Icon  | 
		
  | 
		
  | 
		|
Screen Capture  | 
		
  | 
		
  | 
		|
SRAM Auto Backup  | 
		
  | 
		
  | 
		|
Image Font  | 
		
  | 
		
  | 
		|
Bitmap Font  | 
		
  | 
		
  | 
		|
Standard Font  | 
		
  | 
		
  | 
		5.4.7 System Settings [Display Unit] - [Extended] Settings Guide  | 
	
Device/PLC Communication*2  | 
		
  | 
	||
Number of Device/PLC drivers that can communicate simultaneously  | 
		2  | 
		4  | 
		|
Specify Indirect Device  | 
		
  | 
		
  | 
		|
Import Device/PLC tags  | 
		
  | 
		
  | 
		|
Ethernet Multilink  | 
		
  | 
		
  | 
		7.6 Connecting Multiple Display Units to One Device/PLC (Ethernet Multilink)  | 
	
Device Monitor  | 
		
  | 
		
  | 
		42.4 Monitoring the Value of Device Addresses (Device Monitor)  | 
	
Ladder Monitor  | 
		-  | 
		-  | 
		"PLC Ladder Monitor Operation Manual"  | 
	
Transfer  | 
		
  | 
	||
Network Transfer  | 
		
  | 
		
  | 
		|
Modem Transfer  | 
		
  | 
		
  | 
		|
SIO Transfer (COM Connection)  | 
		
  | 
		
  | 
		|
Memory loader feature  | 
		
  | 
		
  | 
		34.8 Transferring Project Files Using a CF Card or USB Storage  | 
	
CF/SD Card Connection  | 
		
  | 
		
  | 
		|
Connection Key  | 
		
  | 
		
  | 
		|
Common Settings  | 
		
  | 
	||
Change Backlight Color  | 
		-  | 
		-  | 
		|
Clock Update Settings  | 
		
  | 
		
  | 
		|
Start Screen Settings  | 
		
  | 
		
  | 
		|
Date format on CSV file output  | 
		
  | 
		
  | 
		|
Divide destination folders by file numbers  | 
		
  | 
		
  | 
		|
Increase Alarm Type [Extended] settings and Text Table index numbers  | 
		-  | 
		
  | 
		|
Alarm Message Multiple Line Display  | 
		
  | 
		
  | 
		|
Attach Data Value to Operation Log  | 
		
  | 
		
  | 
		|
Changing passwords at run time (CSV file)  | 
		
  | 
		
  | 
		|
Changing passwords at run time (password change screen)  | 
		
  | 
		
  | 
		
	|
Append Date/Time to CSV File Name  | 
		
  | 
		
  | 
		|
Transfer sampling CSV file to FTP  | 
		
  | 
		
  | 
		|
Transferring Sampled Data to the Cloud  | 
		
  | 
		
  | 
		|
Indirectly specify Sampling Frequency and Alarm Settings  | 
		
  | 
		
  | 
		|
Sampling data/Enhanced recipe data format co-exist  | 
		
  | 
		
  | 
		|
Create a recipe (CSV data) index file at runtime  | 
		
  | 
		
  | 
		|
Enhanced Recipes  | 
		
  | 
		
  | 
		|
Extended Script copy file function  | 
		
  | 
		
  | 
		|
Global Trigger  | 
		
  | 
		
  | 
		|
Movie record/play feature  | 
		-  | 
		-  | 
		|
Use image unit  | 
		-  | 
		-  | 
		28.6 Displaying Multiple Video Camera Outputs Simultaneously  | 
	
Sound Output Feature  | 
		-  | 
		-  | 
		|
AUX  | 
		-  | 
		-  | 
		|
Retentive Variables Function  | 
		-  | 
		
  | 
		|
Parts  | 
		
  | 
	||
Selector List  | 
		
  | 
		
  | 
		|
XY Graph  | 
		
  | 
		
  | 
		19.9 Displaying Sampled Data in a Scatter Graph 19.11 Displaying Current Values of Multiple Addresses All at Once in a Scatter Graph  | 
	
Picture Display [CF Image Display]/[SD Image Display] for showing JPEG files  | 
		
  | 
		
  | 
		|
Indirectly specify a block of Alarm parts  | 
		
  | 
		
  | 
		|
Special Data Display [File Manager] sort function and default path  | 
		
  | 
		
  | 
		|
Special Data Display Part [File Manager] copy file to FTP  | 
		
  | 
		
  | 
		|
Message Display's Bulletin Message  | 
		
  | 
		
  | 
		17.5 Displaying the Same Message on Multiple Display Units (Bulletin Messages)  | 
	
Image Sensor Display  | 
		
  | 
		
  | 
		|
Animation  | 
		
  | 
		
  | 
		|
Alarm History Message Flow Display  | 
		
  | 
		
  | 
		|
Alarm History/Sampling Data/Enhanced Recipe Data Refine Search/Sort Function  | 
		-  | 
		
  | 
		20.10 Searching / Sorting Alarm History  | 
	
Alarm Analysis Function  | 
		-  | 
		
  | 
		|
Logic*3  | 
		
  | 
	||
Logic Program Operation  | 
		
  | 
		
  | 
		|
I/O Driver  | 
		-  | 
		-  | 
		|
Function Block  | 
		
  | 
		
  | 
		|
Network  | 
		
  | 
	||
RPA Function  | 
		
  | 
		
  | 
		|
GP-Viewer EX  | 
		
  | 
		
  | 
		|
Web Server  | 
		
  | 
		
  | 
		|
Camera-Viewer EX  | 
		-  | 
		-  | 
		|
Pro-face Remote HMI  | 
		
  | 
		
  | 
		|
  | 
		
  | 
		||
GP Remote Printer Server  | 
		
  | 
		
  | 
		|
Pro-face Connect (Models you can register as SiteManager)  | 
		
  | 
		
  | 
		|
Input Equipment/Peripheral Equipment (USB Device)  | 
		
  | 
	||
USB Keyboard  | 
		
  | 
		
  | 
		|
EZ Illuminated Switch  | 
		
  | 
		
  | 
		|
EZ Tower Light  | 
		
  | 
		
  | 
		Cockpit parts are listed on our support site*4  | 
	
EZ Numpad  | 
		
  | 
		
  | 
		|
EZ Fingerprint Recognition Unit  | 
		
  | 
		
  | 
		|
EZ LAN Adapter  | 
		
  | 
		
  | 
		
*1 While dimmed, brightness settings you can use are 0 to 7.
*2 Depends on the type of connected PLC/Device.
*3 Unable to use with USB-Serial (RS-232C) adaptor cable or USB/RS-422/485 conversion adapter.