Double-click the HSCG instruction to display the following dialog box. In the following dialog box, specify each of the settings.
For details on the special I/O, refer to the following.
31.5 Controlling External I/O in LT3000 / LT4000 / STC6000 Series
Setting |
Operand |
Description |
Setting Range |
---|---|---|---|
CH |
S1 |
Specify the channel number for the high-speed counter. |
CH1 - CH4 |
D1: Instruction Status |
D1 |
Specify the integer variable for storing the status of instruction execution. |
Integer variable only |
Preload value |
D2 |
Specify the variable for storing the preload value of the high-speed counter. The value of #L_HSC*_PLV is stored in the variable specified here. |
Integer variable only |
ON preset value |
D3 |
Specify the variable for storing the ON preset value of the high-speed counter. The value of #L_HSC*_ONP is stored in the variable specified here. |
Integer variable only |
OFF preset value |
D4 |
Specify the variable for storing the OFF preset value of the high-speed counter. The value of #L_HSC*_OFP is stored in the variable specified here. |
Integer variable only |