LT3000 series, LT4000 series and STC6000 series support special inputs and outputs in addition to standard I/O. These include High Speed Counter Input, Pulse Output, PWM Output, and Pulse Catch.
High Speed Counter Input: Can receive a pulse up to 100KHz (up to 50KHz for 2-Phase counter).
Pulse Output: LT4000 series can output a pulse up to 50 KHz. LT3000 series and STC6000 series can output a pulse up to 65 KHz.
PWM Output: Can output a pulse up to 65 KHz.
Pulse Catch: Can detect a pulse at 100 KHz (on for more than 5 microseconds).
Where and how to allocate I/O terminals differs between the standard I/O and special I/O.
Standard I/O
Feature |
Points |
Browse to |
|
---|---|---|---|
LT-3200 Series |
12 points |
||
LT-3300 Series |
16 points |
||
LT4000 Series (DIO model) |
20 points |
||
LT4000 Series (analog model) |
12 points |
||
STC6000 Series |
16 points |
||
Standard Output |
LT-3200 Series |
6 points |
|
LT-3300 Series |
16 points |
||
LT4000 Series (DIO model) |
12 points |
||
LT4000 Series (analog model) |
8 points |
||
STC6000 Series |
16 points |
Special I/O
Feature |
Points |
Remarks |
Data Storage |
---|---|---|---|
High Speed Counter (Single-phase counter) |
4ch (LT3000 Series/STC6000 Series) 2ch (LT4000 Series) |
Measures single-phase input signals. |
|
Counter Control |
- |
Switches up/down |
|
Preload Input |
- |
Changes the current value to the defined value. |
|
Prestrobe Input |
- |
Memorizes the current count value. |
|
Synchronize Output |
- |
Outputs when the count value is within the specified range. |
|
High Speed Counter (2-Phase Counter) |
2ch (LT3000 Series/STC6000 Series) 1ch (LT4000 Series) |
Measures 2-phase input signals. |
|
Counter Control |
- |
Switches up/down. |
|
Phase Factor Mode |
- |
Specifies the measuring method |
|
Preload Input |
- |
Changes the current value to the defined value. |
|
Prestrobe Input |
- |
Memorizes the current count value. |
|
Synchronize Output |
- |
Outputs when the count value is within the specified range. |
|
Marker Input |
- |
Clears the count value. |
|
PWM Output |
4ch (LT3000 Series/STC6000 Series) 2ch (LT4000 Series) |
Outputs the output frequency pulse using the specified on duty. |
|
Normal Pulse Output |
4ch (LT3000 Series/STC6000 Series) 2ch (LT4000 Series) |
Outputs the set frequency based on the set pulse value. |
|
Acceleration/Deceleration Pulse Output |
4ch (LT3000 Series/STC6000 Series) 2ch (LT4000 Series) |
Increases the pulse to the set frequency for output. |
|
2 Phase Pulse Output |
1ch (LT4000 Series) |
Outputs pulse with the specified frequency according to the output mode. |
|
Pulse Catch Input |
4ch (LT3000 Series/STC6000 Series) 2ch (LT4000 Series) |
Captures short pulses (more than 10 µs) and reports when they are captured. |
The same I/O terminals are used for standard input, standard output, PWM output, pulse output, high-speed counter. You cannot simultaneously use the maximum number of terminals for each input or output