Products
Download
Contact us
Back to Top
Connection Device Check Top Back

Connection Configuration Document Report
-> Please choose "reference data" from the following list.

-- Attention --
- Since there are cautions, restrictions, etc., please be sure to confirm "Reference Data" for details.
- Respective link unit, specific connection option, specific cable, etc. are needed for each connection.

: Enabled   : Supports the 3X50 series, the GP3X00 series only
: Need to download the new driver  : Disabled   : Not evaluated

Linkunit I/F Protocol GP2000 Series GP3000 Series reference data
1:1 1:n n:1 1:1 1:n n:1
CPU Direct(Multiple CPU System Connection) RS232C Q Series CPU Direct
ng ng ng ok2 ng ng reference data
Ethernet connector on the CPU unit Ethernet Q Series QnU CPU Ethernet
ng ng ng star star star reference data
QJ71C24N(The first five digits of serial number is 10042 or later.) RS232C Q/QnA Serial Communication
unknown ng ng ok2 ng ng reference data
QJ71C24N(The first five digits of serial number is 10042 or later.) RS422 Q/QnA Serial Communication
unknown ng unknown ok2 ok2 ok2 reference data
QJ71C24N-R2(The first five digits of serial number is 10042 or later.) RS232C Q/QnA Serial Communication
unknown ng ng ok2 ng ng reference data
QJ71C24N-R4(The first five digits of serial number is 10042 or later.) RS422 Q/QnA Serial Communication
unknown ng unknown ok2 ok2 ok2 reference data
QJ71E71 Ethernet Q/QnA Series Ethernet
unknown ng unknown ok ok ok reference data
QJ71E71-B2 Ethernet Q/QnA Series Ethernet
unknown ng unknown ok ok ok reference data
QJ71E71-B5 Ethernet Q/QnA Series Ethernet
unknown ng unknown ok ok ok reference data
QJ71E71-100 Ethernet Q/QnA Series Ethernet
unknown ng unknown ok ok ok reference data
QJ61BT11N CC-Link CC-Link Intelligent Device
unknown unknown unknown unknown unknown unknown no data
QJ61CL12 CC-Link/LT
ng ng ng ng ng ng no data
QJ71BR11 MELSECNET/H(MELSECNET/10 mode)
unknown unknown unknown ng ng ng no data
QJ71LP21-25 MELSECNET/H(MELSECNET/10 mode)
unknown unknown unknown ng ng ng no data
QJ71LP21S-25 MELSECNET/H(MELSECNET/10 mode)
unknown unknown unknown ng ng ng no data
QJ71LP21G-25 MELSECNET/H(MELSECNET/10 mode)
unknown unknown unknown ng ng ng no data
QJ72LP25-25 MELSECNET/H(MELSECNET/10 mode)
unknown unknown unknown ng ng ng no data
QJ72LP25G MELSECNET/H(MELSECNET/10 mode)
unknown unknown unknown ng ng ng no data
QJ72BR15 MELSECNET/H(MELSECNET/10 mode)
unknown unknown unknown ng ng ng no data
QJ71NT11B MELSECNET/H(MELSECNET/10 mode)
unknown unknown unknown ng ng ng no data
QJ71MES96 Ethernet
ng ng ng ng ng ng no data
QJ71WS96 RS232C
ng ng ng ng ng ng no data
QJ71WS96 Ethernet
ng ng ng ng ng ng no data
QJ71CMON RS232C
unknown ng ng unknown ng ng no data
QJ71CMON modular jack
ng ng ng ng ng ng no data
QD51 RS232C
ng ng ng ng ng ng no data
QD51-R24 RS232C
ng ng ng ng ng ng no data
QD51-R24 RS422
ng ng ng ng ng ng no data
QJ71GP21-SX CC-Link IE
ng ng ng ng ng ng no data
QJ71GP21S-SX CC-Link IE
ng ng ng ng ng ng no data
QJ71FL71-T-F01 Ethernet(FL-net)
ng ng ng ng ng ng no data
QJ71FL71-B2-F01 Ethernet(FL-net)
ng ng ng ng ng ng no data
QJ71FL71-B5-F01 Ethernet(FL-net)
ng ng ng ng ng ng no data
QJ71FL71-T Ethernet(FL-net)
ng ng ng ng ng ng no data
QJ71FL71-B2 Ethernet(FL-net)
ng ng ng ng ng ng no data
QJ71FL71-B5 Ethernet(FL-net)
ng ng ng ng ng ng no data
QJ71AS92 AS-i
ng ng ng ng ng ng no data
Ethernet connector on the CPU unit Q Series QnU CPU Ethernet
ng ng ng star star star reference data


Fatal error: Smarty error: [in footer.tpl line 22]: syntax error: unrecognized tag 'var' (Smarty_Compiler.class.php, line 580) in /data/www/www2/etc/agp_connect/lib/Smarty/Smarty.class.php on line 1088