Error Code |
Error Message |
Cause and Troubleshooting |
---|---|---|
0xC0B00001 SAAA001 -1062207487 3232759809 |
System error |
Please restart your computer. If the issue still occurs, install again. |
0xC0B00002 SAAA002 -1062207486 3232759810 |
Cannot process due to shortage of OS resources or memory. |
|
0xC0B00003 SAAA003 -1062207485 3232759811 |
Cannot execute any new process until the server returns a processing result. |
|
0xC0B00004 SAAA004 -1062207484 3232759812 |
The process was interrupted because Pro-Server EX was terminated. |
A fatal error occurred. Restart WinGP and WinGP SDK after executing a forced transfer in GP-Pro EX. |
0xC0B00005 SAAA005 -1062207483 3232759813 |
The process was suspended because Pro-Server EX was terminated during the process. |
|
0xC0B00006 SAAA006 -1062207482 3232759814 |
Cannot process because Pro-Server EX has already been terminated. |
|
0xC0B00007 SAAA007 -1062207481 3232759815 |
The specified connector has already been registered. The application is already in execution. |
Please restart your computer. If the issue still occurs, install again. |
0xC0B00008 SAAA008 -1062207480 3232759816 |
An error occurred in an OLE function. Cannot convert the data. |
|
0xC0B0000A SAAA010 -1062207478 3232759818 |
Cannot refer to the resource because Pro-Server EX has not yet been started. |
|
0xC0B0000B SAAA011 -1062207477 3232759819 |
Cannot request the system to execute processing because Pro-Server EX has not yet been started. |
|
0xC0B0000C SAAA012 -1062207476 3232759820 |
The system is broken. Cannot process. |
|
0xC0B00011 SAAA017 -1062207471 3232759825 |
An error occurred when accessing the XX file. File lock (XX: File name) |
Please restart your computer. If the issue still occurs, install again. |
0xC0B00012 SAAA018 -1062207470 3232759826 |
Too many connectors to register. |
|
0xC0B00029 SAAA041 -1062207447 3232759849 |
Failed to get device information from the PRX file. |
The screen project file may be damaged. Restart WinGP and WinGP SDK after executing a forced transfer in GP-Pro EX. |
0xC0B0002A SAAA042 -1062207446 3232759850 |
Failed to get symbol info from the PRX file. |
|
0xC0B0002B SAAA043 -1062207445 3232759851 |
Failed to get the device address from the PRX file. |
|
0xC0B0002C SAAA044 -1062207444 3232759852 |
Failed to get setting information from the PRX file. |
|
0xC0B0002D SAAA045 -1062207443 3232759853 |
Failed to create temporary file. |
A temporary file creation folder may not have sufficient free space. Please check whether the drive has enough free space, and increase it if it is insufficient. |
0xC0B0002E SAAA046 -1062207442 3232759854 |
Cannot open the PRX file. |
The screen project file may be damaged. Restart WinGP and WinGP SDK after executing a forced transfer in GP-Pro EX. |
0xC0B0002F SAAA047 -1062207441 3232759855 |
Failed to delete temporary file. |
Please run again. |
0xC0B00030 SAAA048 -1062207440 3232759856 |
The specified PRX file has an error. |
The screen project file may be damaged. Restart WinGP and WinGP SDK after executing a forced transfer in GP-Pro EX. |
0xC0B00031 SAAA049 -1062207439 3232759857 |
The PRX file does not have necessary data. |
|
0xC0B00032 SAAA050 -1062207438 3232759858 |
The specified file is not a PRX file. |
|
0xC0B00062 SAAA098 -1062207390 3232759906 |
The network project file is broken. Cannot read. Please confirm whether the file you specified is a real network project file. |
A fatal error occurred. Restart WinGP and WinGP SDK after executing a forced transfer in GP-Pro EX. |
0xC0B00063 SAAA099 -1062207389 3232759907 |
Cannot write to the network project file. |
Please check whether the disk space is sufficient, and the hard disk has any problem. |
0xC0B00064 SAAA100 -1062207388 3232759908 |
The file is not a network project file, or its version is old. Cannot read the data. |
A fatal error occurred. Restart WinGP and WinGP SDK after executing a forced transfer in GP-Pro EX. |
0xC0B00065 SAAA101 -1062207387 3232759909 |
The specified device was not found in (XX). It may have been deleted or renamed. Please review the settings. (XX: NODE name) |
|
0xC0B00066 SAAA102 -1062207386 3232759910 |
The specified NODE (XX) has not been registered. There is a conflict. Please review the settings. (XX: NODE name) |
|
0xC0B00067 SAAA103 -1062207385 3232759911 |
The specified NODE info is incorrect. No NODE info exists. |
|
0xC0B00068 SAAA104 -1062207384 3232759912 |
The device setting in the system area of the specified NODE (XX) has an error. Please check the device you set. (XX: NODE name) |
|
0xC0B00069 SAAA105 -1062207383 3232759913 |
(XX: XX) is invalid as a device or symbol. Cannot analyze. (XX: Device/Symbol name) |
A nonexisting device/symbol name has been specified. Please confirm the symbol, following the direction of the message. If it does not solve the problem, the screen project file may be damaged. Restart WinGP and WinGP SDK after executing a forced transfer in GP-Pro EX. |
0xC0B0006C SAAA108 -1062207380 3232759916 |
The network setting is broken. |
Please review the network settings. |
0xC0B00078 SAAA120 -1062207368 3232759928 |
(Symbol Sheet: XX Symbol: XX Address: XX) is invalid as a device address. (XX: Symbol Sheet name, XX: Symbol name, XX: Address) |
The screen project file may be damaged. Restart WinGP and WinGP SDK after executing a forced transfer in GP-Pro EX. |
0xC0B0007C SAAA124 -1062207364 3232759932 |
(Symbol Sheet: %s Symbol: %s Address: %s) is beyond the valid device range. (XX: Symbol Sheet name, XX: Symbol name, XX: Address) |
|
0xC0B00082 SAAA130 -1062207358 3232759938 |
The specified node has not been registered in the network project. (XX:) NODE name |
A fatal error occurred. Restart WinGP and WinGP SDK after executing a forced transfer in GP-Pro EX. |
0xC0B00083 SAAA131 -1062207357 3232759939 |
The specified node (XX) is not a GP series node. (XX:) NODE name |
|
0xC0B00084 SAAA132 -1062207356 3232759940 |
The device of the specified node (XX) is not supported. (XX:) NODE name |
|
0xC0B00095 SAAA149 -1062207339 3232759957 |
(Symbol Sheet: XX Symbol: XX Number of Devices:XX) is beyond the range of the number of devices. (Valid Range: xx...xx) |
Decrease the number of symbols registered on the GP-Pro EX Symbol screen. |
0xC0B00096 SAAA150 -1062207338 3232759958 |
(Symbol Sheet: XX Group: XX) has the number of rows beyond the limit. Please reduce it. (XX rows or less) |
|
0xC0B0009C SAAA156 -1062207332 3232759964 |
In a symbol sheet, 2 symbol/group names are redundant. (Symbol Sheet: XX Name1: XX Name2: XX) |
Change the name of the symbol registered on the GP-Pro EX Symbol screen. |
0xC0B0009D SAAA157 -1062207331 3232759965 |
The device driver of (Node: XX) is not supported. (Necessary driver has not been installed.) (XX: NODE name) |
Please install according to Device/PLC differences. |
0xC0B000A9 SAAA169 -1062207319 3232759977 |
(XX:XX) The specified Device or Symbol is beyond the valid device range. (xx: Device, xx: Number)) |
A device beyond the valid device range was accessed. |
0xC0B000E0 SAAA224 -1062207264 3232760032 |
Warning: In different symbol sheets, 2 symbol/group names are the same. To use the same name, please specify the sheet name to which this symbol/group belongs. (xx: Existing symbol sheet name, xx: Symbol sheet name to which the same symbol name belongs, xx: Same symbol name) |
In the GP-Pro EX Symbol setting screen, please change the name to avoid name duplication. |
0xC0B000E1 SAAA225 -1062207263 3232760033 |
Warning: The symbol/group name is the same as a symbol sheet name. To use the same name, please specify the sheet name to which this symbol/group belongs. |
|
0xC0B000E4 SAAA228 -1062207260 3232760036 |
Warning: The array variable (XX) has too many elements for API Communication for WinGP to access the whole array.In API Communication for WinGP, only XX elements from the head are accessible. (XX: Symbol name, XX: Array Element number) |
1. Consider registering the array by splitting it into multiple parts in GP-Pro EX. 2. If the array cannot be split, when importing the GP-Pro EX project file to the network project in Pro-Server EX, there is a function that automatically splits array variables that exceed the number that can be accessed simultaneously, and registers them as multiple symbols. |
Line 1: error code
Line 2: Integrated error code
Line 3: Base10 signed error code
Line 4: Base10 unsigned error code