Error Code |
Error Message |
Cause and Troubleshooting |
---|---|---|
0xC0AF0001 RYAA001 -1062273023 3232694273 |
The specified shared memory already exists. |
A fatal error occurred. Restart WinGP and WinGP SDK after executing a forced transfer in GP-Pro EX. |
0xC0AF0002 RYAA002 -1062273022 3232694274 |
The specified shared memory does not exist. |
|
0xC0AF0003 RYAA003 -1062273021 3232694275 |
A shared memory already exists, but its memory size is less than specified. |
Please close another application or restart the OS. |
0xC0AF0004 RYAA004 -1062273020 3232694276 |
Cannot create a shared memory due to insufficiency of memory or resource. |
|
0xC0AF0005 RYAA005 -1062273019 3232694277 |
Could not start TdasEngine because it is already in execution or termination |
A fatal error occurred. Restart WinGP and WinGP SDK after executing a forced transfer in GP-Pro EX. |
0xC0AF0006 RYAA006 -1062273018 3232694278 |
Could not start TdasEngine because it is already in suspension or termination. |
|
0xC0AF0007 RYAA007 -1062273017 3232694279 |
Could not register the operation in TdasEngine. |
|
0xC0AF0008 RYAA008 -1062273016 3232694280 |
Cannot execute State Transition of TdaInfo because a small service is now in transition. |
|
0xC0AF0009 RYAA009 -1062273015 3232694281 |
The device name (XX) specified as the destination NODE does not exist. (XX: Device/PLC name) |
|
0xC0AF000A RYAA010 -1062273014 3232694282 |
Cannot execute the operation due to the invalid state of the small service. |
|
0xC0AF000B RYAA011 -1062273013 3232694283 |
Cannot execute the operation because the small service is not in operation. |
|
0xC0AF000C RYAA012 -1062273012 3232694284 |
Cannot execute the operation because the small service is not in operation. |
|
0xC0AF000D RYAA013 -1062273011 3232694285 |
The I/F of an unsupported small service was called.I |
|
0xC0AF0010 RYAA016 -1062273008 3232694288 |
Could not register the item because of insufficient memory. |
Please close another application or restart the OS. |
0xC0AF0011 RYAA017 -1062273007 3232694289 |
Accessed a device in which no item is registered. |
A fatal error occurred. Restart WinGP and WinGP SDK after executing a forced transfer in GP-Pro EX. |
0xC0AF0012 RYAA018 -1062273006 3232694290 |
Accessed an out-of-range device. |
A device beyond the valid device range was accessed. |
0xC0AF0013 RYAA019 -1062273005 3232694291 |
Failed to register the specified cluster because an invalid item is specified in it. |
A fatal error occurred. Restart WinGP and WinGP SDK after executing a forced transfer in GP-Pro EX. |
0xC0AF0014 RYAA020 -1062273004 3232694292 |
The specified data type is not a valid data type. |
|
0xC0AF0015 RYAA021 -1062273003 3232694293 |
An illegal access type was specified. |
|
0xC0AF0016 RYAA022 -1062273002 3232694294 |
The specified data type is illegal. |
|
0xC0AF0017 RYAA023 -1062273001 3232694295 |
The number of data you specified is too many to write (Please reduce it to XX or fewer) (XX: Data number) |
|
0xC0AF0018 RYAA024 -1062273000 3232694296 |
The operation result to write is below the lower limit value. |
Attempted to write an out of range value. Please change the setting to write an in-range value. |
0xC0AF0019 RYAA025 -1062272999 3232694297 |
The operation result to write is beyond the upper limit value. |
|
0xC0AF001A RYAA026 -1062272998 3232694298 |
Could not send processing request to the network destination due to insufficient memory. |
Please close another application or restart the OS. |
0xC0AF001B RYAA027 -1062272997 3232694299 |
The specified group was not found. |
A fatal error occurred. Restart WinGP and WinGP SDK after executing a forced transfer in GP-Pro EX. |
0xC0AF001C RYAA028 -1062272996 3232694300 |
The two compared access tickets differ in their nodes, equipment, or devices. |
|
0xC0AF001D RYAA029 -1062272995 3232694301 |
The specified access ticket is not for this node. |
|
0xC0AF001E RYAA030 -1062272994 3232694302 |
Could not register the cache because of insufficient memory. |
Please close another application or restart the OS. |
0xC0AF0020 RYAA032 -1062272992 3232694304 |
The access ticket you tried to use in block access is not a block type. |
A fatal error occurred. Restart WinGP and WinGP SDK after executing a forced transfer in GP-Pro EX. |
0xC0AF0021 RYAA033 -1062272991 3232694305 |
The small service to process was not found. |
|
0xC0AF0022 RYAA034 -1062272990 3232694306 |
The size of block access to the device exceeded the limit. |
The max buffer size for Device Block Write/Read is 10 KB. Please set a size less than that. |
0xC0AF0023 RYAA035 -1062272989 3232694307 |
A different network project is being used. |
A fatal error occurred. Restart WinGP and WinGP SDK after executing a forced transfer in GP-Pro EX. |
0xC0AF0030 RYAA048 -1062272976 3232694320 |
A communication error occurred during communication with the destination node. Please confirm that the network connection to the node has been properly established. |
Check that the LAN card settings are correct. |
0xC0AF0031 RYAA049 -1062272975 3232694321 |
The destination node did not responded within the specified time. Please confirm that the network connection to the node has been properly established. |
|
0xC0AF0032 RYAA050 -1062272974 3232694322 |
The destination node did not responded within the specified time. Please confirm that the network connection to the node has been properly established. |
|
0xC0AF0033 RYAA051 -1062272973 3232694323 |
Communication with the destination Node stopped because the destination or local Node closed. |
Set WinGP node online. |
0xC0AF0040 RYAA064 -1062272960 3232694336 |
Failed to read the device. |
The data may have been read into an illegal or undefined device address. Please specify a proper device address. |
0xC0AF0041 RYAA065 -1062272959 3232694337 |
Failed to write the device. |
|
0xC0AF0045 RYAA069 -1062272955 3232694341 |
The specified request is not supported. |
A fatal error occurred. Restart WinGP and WinGP SDK after executing a forced transfer in GP-Pro EX. |
0xC0AF0046 RYAA070 -1062272954 3232694342 |
The specified request is not supported. |
|
0xC0AF0050 RYAA080 -1062272944 3232694352 |
The project ID of the network project file is different. (A different network project is being used.) |
|
0xC0AF0051 RYAA081 -1062272943 3232694353 |
The network project file does not have necessary data. |
|
0xC0AF0052 RYAA082 -1062272942 3232694354 |
The network project file is damaged. |
|
0xC0AF0053 RYAA083 -1062272941 3232694355 |
The network project file does not exist. |
|
0xC0AF0067 RYAA103 -1062272921 3232694375 |
Operation was interrupted because GP Online was terminated. |
The operation was interrupted because WinGP Online was terminated. To finish the operation, put WinGP online and retry. |
Line 1: error code
Line 2: Integrated error code
Line 3: Base10 signed error code
Line 4: Base10 unsigned error code