17.6.2.2 Text Display - Basic Settings / Extended

When [Specify Text File Number] is [Constant]

Text File Number

Set a text file number for the text from 1 to 8,999.

Start Row Bit Address

Set the start bit address to store the text display's start row specification data. You can set a bit address or a word address to specify bits.

The display start row is determined by the data stored in the range of the start row to the bit specified in [Number of Bits] and the [Rows Scroll].

Number of Bits

Sets how many bits, from the [Start Row Bit Address], are used for Display Start Row Specification. Select a value from 1 to 16. The number of bits to use will differ depending on the specified [Rows Scroll].

For example, 12 rows of text will be scrolled by 4 rows each time = using 2 bits

Because the number of bits used is set from the Display Start Row Specification data, the empty portion of the Reserved Area can be used for other purposes.

For example, Start Row Bit Address = D100 8 bit, Number of Bits = 4

For example, Start Row Bit Address = D100 12 bit, Number of Bits = 10

Rows Scroll

Set the number of rows the display scrolls from 1 to 256 when the Start Row data changes.

Display Start Row = Rows Scroll (Display Start Row data -1) +1

For example, [Display Rows] = 4, [Rows Scroll] = 4

Display Start Row data = 1Display Start Row = 1

Display Start Row data = 2 Display Start Row = 5

Display Start Row data = 3 Display Start Row = 9

If the Display Start Row is "0", the text does not display, and the Message Display's Display Area is shown with a transparent color.

When [Specify Text File Number] is [Address]

Text File Number Word Address

Set the address where the text file number to display is stored. The text with the number stored in this address displays.

Data Type

Select the data type of the text file number to be stored in [Address].

Specify Start Row

Choose how the text's Start Row is specified.

Specify a set constant as the Display Start Row.

Specify the address where the display start row is stored.

Constant

Desired text displays starting from fixed lines.

Start Row

Set a number for the text's Display Start Row from 1 to 512.

When the start row does not exist, the operation is ignored. The previously displayed rows remain.

Address

Displays desired text starting from various rows.

Start Row Address

Set the address of the word address that stores the text's Display Start Row. The Display Start Row is decided by the data stored in this field and by the [Rows Scroll].

When the start row does not exist, the operation is ignored. The previously displayed rows remain. The display is cleared when the Display Start Row is set to "0".

Data Type

Choose the format for the text's Display Start Row.

Rows Scroll

Set the number of rows the display scrolls from 1 to 256 when the Start Row data changes.

Display Start Row = Rows Scroll (Display Start Row data -1) +1

For example,

[Display] tab [Display Rows] = 4, [Rows Scroll] = 4

Display Start Row data = 1Display Start Row = 1

Display Start Row data = 2Display Start Row = 5

Display Start Row data = 3Display Start Row = 9

If the Display Start Row data is "0", the text does not display, and the Message Display's Display Area is shown with a transparent color.