**************************************************************** GP-PRO/PBIII C-Package03 SP2 **************************************************************** MARCH 09, 2007 Digital Electronics Corporation of Japan Foreword Thank you for purchasing the GP-PRO/PBIII C-Package03 software. GP-PRO/PBIII C-Package03 SP2 is a combined software package of both GP-PRO/PBIII Ver. 7.27 for Windows and Pro-Control Editor Ver. 5.10. The GP-PRO/PBIII Ver. 7.27 for Windows software (hereafter [PRO/PBIII Ver.7.27]) is designed to create screen data for Pro-face GP70, GP77R, GP2000, ST, LT, GLC100, GLC300, and GLC2000 Series programmable operator interfaces. The Pro-Control Editor Ver. 5.10 software (hereafter [Pro-Control Ver.5.10]) is designed to create ladder logic program exclusively for LT, GLC100, GLC300, and GLC2000 Series programmable operator interfaces. Designed from the ground up for Windows OS, the GP-PRO/PBIII C-Package03 SP2 software provides easy-to-use, high-performance functionality. =========================================================== Table of contents =========================================================== 0. Bug Fix List 0-1. GP-PRO/PBIII Bug Fix List 0-2. GP System Bug Fix List 0-3. Pro-Control Bug Fix List 0-4. Protocol Bug Fix List 1. GP-PRO/PBIII C-Package03 SP2 New Features 1-1. Newly Supported Protocols 1-2. GP-PRO/PBIII New Features =========================================================== 0. Bug Fix List =========================================================== 0-1. GP-PRO/PBIII Bug Fix List /-- PRO/PBIII V7.27--/ 1. In Print, line feeds are not inserted for the expression in the trigger condition of "Extended SIO Script", "D-Script" and "Global D-Script". 2. When Text Table Convert is executed on OS with other languages than Japanese and English, inappropriate characters are displayed. 3. When "Address Block Conversion" is repeated, files may be broken. 4. When the screen data is edited in using the GP unit vertically, parts on Window Parts seem to be shifted from the correct position. 5. The preview screen of the Logging function setting is not displayed normally. 6. When gAssign Addressesh in "Duplicate" is executed, the station number is changed. /-- PRO/PBIII V7.26h--/ 1.There is something not correctly displayed when it makes to display OFF of the tag name. 2.When you open the "Trend Screen" setting with Ver.7.26 There is a thing that the set address is changed. 3.When the project in "the hierarchical display mode of Project Manager" without the S20 file is opened, the reproduction doesn't generate the S20 file. 4.When you do the penetration setting of the character string by the batch edit of "Screen Data List" It is not penetrated and might be the blink. 5.When you set it in "Expansion Modbus", and set it to "Yes" on "Serial I/F Switchover". The setting changes the received project into "No". /-- PRO/PBIII V7.26g--/ 1."Extended SIO Script", "D-Script" and "Global D-Script" It is not correctly displayed in the "Cross Reference" when there is "TAB" code in the comment on the function. 2."Extended SIO Script", "D-Script" and "Global D-Script" When the hierarchy of the function call becomes deep, the screen editor is forcibly terminated. 3.The data is transferred to GP a big size screen with Ver.7.26 there is a thing that cannot be forwarded by the error's of "The screen size exceeds it..." going out. 4.Even if "Window screen" and "Video screen" are deleted , the screen remains in "Up-loading" information. /-- PRO/PBIII V7.26f--/ Reservation /-- PRO/PBIII V7.26e--/ 1.The problem that the LS word address is changed when the LS bit address and the LS word address are mixed in D-Script is corrected. /-- PRO/PBIII V7.26d--/ 1.When the screen data size is an upper bound, the screen data cannot be sent to GP. /-- PRO/PBIII V7.26c--/ 1.The libraries that exceed the maximum value are created in some cases. /-- PRO/PBIII V7.26b--/ 1. When Table switching is performed, the Row No. of the text screen is changed. 2. In the Alarm function, TABLE1 in the text data is not displayed. 3. When "Multiple Copies" is executed for Keypad Input Display, the Completion Bit address is not incremented normally. 4. Drag & Drop cannot be executed from the library. 5. In the window appeared after "Convert image" is selected, a file including the one-byte character of "%" cannot be opened normally. 6. The index character strings are not displayed on the screen after Text Table Convert is executed. 7. Character strings other than the ones displayed on the text screen cannot be seen. /-- PRO/PBIII V7.26a--/ 1. When a copy direction is changed in "Duplicate", the value in "Number of copy" is returned to a default. 2. When you use a tab key and reach "Character size" in parts, you cannot move from there to another setting. /-- PRO/PBIII V7.26--/ 1. The error message ("WARNING, It is excess of the screen size.") is added that appears when the edited data exceeds the specified screen size. 2. When the monochrome model type is edited using "the hierarchical display mode of Project Manager", the color settings may be made. 3. Once you put a check mark in "Sort" in Alarm Editor, you cannot uncheck it. 4. The value for the alarm history held in GP system "Q-Tag Settings" is changed while the alarm is imported. (Values after Block 4 may be changed.) 5. When a Message Display is edited under the condition that the grouped object is placed on the edit screen, the grouped object is moved. 6. In the map function of "Global Cross Reference", the specified address is not displayed. 7. When "Summary" is imported, the areas where only addresses are set move up. 8. When "Password" is set and a comparison with the GP unit is made, the error saying "No Upload Information in GP Data File" appears and the comparison cannot be performed successfully. 9. When you change the title and save it in the "Open Screen" dialog, the screen editor is forcibly terminated. 10. In "Parts List", some of the "Keypad Input Display" settings are displayed improperly. 11. In "the hierarchical display mode of Project Manager", the text screen size is displayed two times as large as the specified size. 12. Closing the condition setting dialog in "CSV Data Transfer Function" causes the forced termination. /-- PRO/PB V7.25--/ 1. The large screen data cannot be uploaded successfully when Ver. 7.24 is used. /-- PRO/PB V7.24--/ 1. Cancellation of password entry causes the save error when you try to open the project with the protect function enabled. 2. In "Compare" of "Options" on the "Transfer" menu, an error "Not found 2Way setting in PRW file." appears. 3. In the D-script screen, the cut data including the information entered in the "Action" area is saved to the clipboard. 4. Although "Bitmap" is not selected in the "Cover Page" setting, an error "Bitmap File Not Selected!" appears. ("Project Manager" -> "Print"-> "Cover Page") 5. When the setting where "Window Screen" is to be used is enabled for the base screen, the preview screen is shifted from the correct position. 6. The line No. of the text is entered in "OFF Text" and the state is changed. Then, even when the line No. of the text is entered in "ON Text", the value entered in "OFF Text" remains. 7. When the "Prepare" feature is used, "Logging (Print) - Error, No Address found for Alias." is displayed and the transfer process cannot be performed. 8. The address specified for D-script Function cannot be displayed in Global Cross Reference due to the address description method. 9. When Text Table is used, the message in Message Display turns 90 degrees. 10. When the title is changed using "Change" in "Open Screen", the "Prepare" feature is disabled. 11. When "Device/PLC Type" is changed, the text data mode in GP settings is mistakenly changed to the initial setting before change, although it should be the default after change. 12. Alarm is exported in the CSV format, the block attributes after Block 4 are exported in the incorrect settings. 13. When a project is edited where the trend parts are used in Editor (Ver.7.11 or later), some of the trend parts settings become abnormal. 14. When Text Table is used, "Center Arrangement" in "Message Display" cannot be reflected. 15. Transfer to GLC2000 series cannot be performed via Ethernet. /-- PRO/PB V7.23a--/ 1. When "Extended SIO Script", "D-Script" and "Global D-Script" are edited and the data are transferred to GP , the error "003" may occur on GP. 2. When the base screen where the Function Switch is placed is transferred to GP, the drawing size may be changed depending on the location of the Function Switch. 3. When "Compare" of "Option" in "Transfer" is used, the message saying "Not found Popup Keypad in GP"" appears. 4. In "Function Switch", two or more lines cannot be scrolled up/down with Q-tag cursor. 5. The same title is put on all the text screens in "Text Table Converter". 6. In "Basic Alarm Settings", the contents of the message may be set to the address entry field. 7. "Address Conversion" cannot be executed at the time of the first entry. 8. When "Text Table Converter" is used , the "Align" information for each part cannot be inherited. 9. While "Text Table Converter" is used in "Basic Alarm Settings", the entered area cannot be returned to a blank. 10. The "Centering Arrangement" check box may disappear in the "Text" function. 11. X-coordinate of the window screen cannot be corrected. 12. CSV file with a large amount of filing data cannot be imported. 13. When the "Text Table Converter" function is used, the alarm message is assigned to the address that does not exist in "Text Table". 14. When "File Converter" is used, an incorrect value may be entered in the watchdog function. 15. When "Change Project Manager" is executed, the file save error may occur. 16. The alarm message that appears in data logging settings is inadequate. 17. When "Browse Text Table " is selected for a part label, the texts written on the OFF label cannot be copied to the ON label. 18. The window cannot be saved accurately in the hierarchical display mode of Project Manager. 19. When saving the graph type, the incorrect data is created. 20. Even when the entry order setting is canceled in Keypad Input Display, the setting remains. 21. PRW file cannot be created using the upload information. 22. A scroll bar does not appear in the screen window. 23. "Address Range Conversion" cannot be executed. 24. Even when the address conversion is executed in changing the PLC type, the address cannot be converted successfully. /-- PRO/PB V7.23--/ 1.When screen data and editor data are transferred to "GLC" or "LT", "Control Data" in the "Transfer Settings" menu may not be used. /-- PRO/PB V7.22--/ The following bugs have been fixed this time. 1. All the contents of the "Start menu" are deleted at the time of the installation. 2. While "Perpendicular" is used for "GP2600" and "GLC2600", lamp parts blink. 3. When "Spacing" is specified in one-line display of "Text Table" , the display on GP is shifted. 4. Although "Extended Function" is enabled in "Basic Alarm Settings" , the non-extended data is created and, as a result, the Q-tag data on GP may not be displayed normally. 5. When "Symbol" is copied using "Copy Screen", the allocation of the "Symbol" may be shifted. 6. The function to recreate the "Image Font" data has been added to "Rebuild Tool". 7. While "Perpendicular" is used for GP, A-tag and Q-tag may be rotated for 90 degrees. 8. When "Text Table" is viewed under the condition that the first setting of "Message Display" is not specified, "Center Arrangement" cannot be executed. 9. When updated to Ver.7.20 or later version, "System Screen" in "Transfer Settings" is initialized. /-- PRO/PB V7.21a--/ 1. When "Export Symbol" is executed under the condition that S1 file system PLC is used, the data in "Symbol Editor" may be changed. 2. When "Global Cross Reference" is used for a lot of devices, much time is required. 3. When "Copy screen" is executed for the text screen in which a "Multilanguage" feature is used, the screen is not copied successfully. 4. When an INDEX process is executed for the grouped texts via "Text Table Converter", inappropriate INDEX texts may appear. 5. Overwrite operation may be performed without displaying the overwrite confirmation message for the already-existed base screen number. 6. The calculation method for "Upload Information" is not correct. 7. When the file that is created using "*.TXT" is imported to the text screen, a comment is set with 30 or more characters. 8. When a CSV file with blanks is imported to the text screen, blanks are cut and lines below them are moved up. 9. Display position of Selection Tool Box is inconvenient to use. 10. When screen data transfer is executed via CF Memory Loader Tool, the 2-Way Driver disappears. 11. When "Indirect" is selected in the "Color Type" field of the "Keypad Display [Shape/Color]" settings, "Alarm Settings" cannot be specified. 12. Both "Extended Settings" and "Video Settings" are allocated to "Global Cross Reference" as a default. 13. In "File Converter", "ST" cannot be selected for "Display Type" of "Convert To" menu. 14. "Screen Capacity" may include the capacity of the popup keypad in GP70 series. 15. When opening the text screen that is copied using the "Copy screen" command, texts appeared in "Title" field are not displayed normally. 16. Even when TCP font and "Bold" setting are specified in N/E-tags, the font is not displayed in the "Bold" character type on GP units. 17. "Global D-Script" and "D-Script Function List" cannot be printed in the hierarchical display mode of Project Manager. 18. Base screen may be displayed abnormally. 19. When "Cancel" is clicked in "GP Settings" under the condition that S1 file system PLS is used, the start address of the system may be shifted to the improper one. 20. When opening a project on the file created with the older file version, the older file version may not be changed to the correct one and the file is opened in the older version. /-- PRO/PB V7.21--/ The following bugs have been fixed this time. 1. Addresses in "D-Script" may not be converted when the "Address Conversion" command is used. 2. When opening with the Ver.7.20 in the case where "MODBUS TCP" is selected as the external communication device, the setting cannot be carried out in the "GP Setup" menu. 3. Texts of "Big5" may be displayed as the texts of "GB2312". 4. When the texts including a linefeed code is imported to "Text Table", the import is not successful. 5. "D-Script" is not operated normally when the "if" or "loop" expression has "memcpy_EX" or "memset_EX" where the 32-bit device is set. /-- PRO/PBIII V7.20b--/ The following bugs have been fixed this time. 1. When "Go To Screen" or "Previous Screen" is specified in "Function" on the "General Settings" tab, "Function Switch Settings" cannot be enabled. 2. In WindowsXP, an appropriate error message may not appear in File Converter. 3. The "Grayscale (Normal)" and "Grayscale (Reverse)" settings of "Convert (Import) Image" in monochrome type GP series can be used which should not be. Or, when conversion process is executed, monochrome is converted into color. 4. When "Converting Addresses and Device Codes" of "Global Fn Key" is executed in handy type GP series, "Operation Switch" and "Function Keys" cannot be operated. 5. When the screen No. is changed in the "Rename" dialog of "Screen Editor", the transfer preparation for the changed screen cannot be started. 6. When the simulation is completed, unnecessary messages on the GP system information are displayed. 7. When "Multiple Copies" for K-tag is executed, an error message representing the excessive address range may appear. 8. When the already-registered screen is selected during the "Addc" process of "Window Registration", the registration No. and title are displayed in Title area. 9. When "Bit" is selected for "Start" of "Keypad Display" after the GP type is changed, "Exists" is specified for "Popup." 10. When the base screen is copied and pasted in Project Manager Hierarchical Display, the address value may be changed. 11. The position of the cursor selected in "Screen Data List" may shift from the designated one. 12. When "Allen Bradley SLC500 Series" of "Rockwell (Allen-Bradley)" is selected for "Device/PLC Type", bit addresses cannot be displayed correctly in "Global Cross Reference". 13. When the Alarm Editor is closed after importing the export data (* ala) whose "Use extended function" is ON in the Alarm Editor, the GP system settings are initialized. 14. When converting the GPPRO2 file to ProPBWin, the contents of the system area may not be reflected. 15. When a read error occurs in executing "Global Cross Reference," there is no message box displayed regarding the error information. 16. Even if PLC type is changed using "Converting Addresses and Device Codes," the address cannot be converted. 17. When selecting the device with the offset value (LS) of CF File Operation in "D-Script," symbol options appear from the pull-down menu. Even if a symbol is selected, however, the [OK] button is disabled. 18. In "Global Cross Reference," the valuable specified in "Global D-script" may not be displayed. 19. The part of the English message is incorrect which appears when "Yes" is selected in "Serial I/F Switchover" for ST403. 20. In ST Series, English spelling of the "New" dialog box is incorrect. 21. Editing "Picture Displays" may cause an application error and forcibly shut down the software. 22. When the GP unit is used vertically, the entire window may not be displayed. 23. Changing the "*.MEM" file to *.PRW" file may cause forced termination. 24. When the "Keypad Display" screen is opened in using the GP unit vertically, an application error may occur and forcibly shut down the software. 25.When the drawing data is printed using the GP unit vertically, an application error occurs and software can be forcibly terminated. /-- PRO/PBIII V7.20 -- / 1. When a value other than 0 is configured for "Decimal Places" in the "Display Format" of Keypad Input Display, and then the "Display Format" is later changed to "Char. String", a decimal point will be displayed. 2. "OMRON SYSMAC-CS1 SERIES" is displayed twice under "Device / PLC Type" while saving using "Save as" function. 3. "An Application error" may occur while setting up "display" of "Data Logging settings." 4. If multiple blocks are used when "Extended Function" and "Block" of "Alarm" are in use, "Alarm messages" other than "Block 1" do not operate correctly. 5. If contents of "Basic Alarm Settings" are all selected, deleted and later pasted, address may be set to 0. 6. If "Screen number" is changed in the "Drawing board", copy of "Color Control" is not carried out. 7. While importing CSV, even if you clear one table in the Text Table Editor, the number of "Characters" of other tables are not cleared. 8. Although "Extended Function" of "Alarm" is not in use, it becomes possible to setup "Multiple", "Accumulate" and "Level" in the "Display Format" of "Q Tag Setting". 9. Software does not operate correctly when "HEX Landscape" of "Popup Keypad Edit" is chosen while screen is open in "Drawing Board", and when the "Drawing Board" is opened from hierarchical display of project manager and icon of "Color Control" in "Edit Tool Bar" is clicked. 10. Even though "Save as default Keypad" is done in "Popup Keypad Edit", it may not be saved. 11. Once updated to C-Package03 SP1 (Ver.7.12), installation of GP37W/GP37W2 cannot be performed. 12. The title of a screen is displayed incorrectly if "Text Landscape" is selected in "Popup Keypad Edit". 13. If "Indirect" is setup in "Alarm Type" of "Alarm Settings" for "Keypad Input Display", "Min. Value" is not displayed in the "List" of "Global Cross Reference". 14. "Invalid Address Error" may occur in "Trend Screen" while preparing transfer. 15. In "Import/Export of Text screen", "GP Font" - "ASCII(Code Page 850)" may not display correctly. 16. Error may display in "Logic Program" transfer part when using "USB Transfer" on GLC. 17. When selecting "GP2000H series", "Clear Area" displays as a different size to that which has been setup in "Popup Keypad Edit". 18. If you export to CSV file in Symbol Editor, the order may not be aligned correctly. 19. In "Text" if you change "Image Font" setup to another font, and then return to the original font, the font style may be changed. 20. If the PC is in "Hyper Threading Mode", screen transfer may not be performed correctly. 21. If "Device/PLC Type" is "Siemens S7-300/400 via MPI", LS backup function is not retained. 22. If 20 or more Windows are registered, then "Print" of "GP Setup" cannot be carried out correctly. 23. In the "specify entering order" of a "keypad input display setting", when the "pop-up keyboard" has been arranged on the square of a screen, the places displayed as the set-up place differ. 24. When GP type was changed into "GP77 series" from "GP70 series", the contents of the message BOX at the time of an "alarm editor" performing "block setup" were unsuitable. 25. When the group-sized object is edited from a "screen data list", there is a case where it stops operating correctly. 26. If "CF card auto save" by the loop of a "data logging setting" is performed, a "header" will be attached to a "CSV file" each time. 27. In a "text table editor", if additional edit is performed, an "application error" will occur. 28. If a "global D script" is chosen and closed in the state where the screen is not opened, to a "screen editor", an "application error" will occur. 29. Operation of other applications becomes slow at the time of screen transmission. 30. In a "project comparison tool", if the "PRW file" which exists at hand is compared with the "PRW file" uploaded from GP, it will be judged as difference in spite of the same data. 31. In a "text table editor ", in case the number of characters exceeds by the half width of one character, if "it imports", the last character may not be displayed correctly. 32. When the CSV file containing the data of the sign of "+" and "-" is taken in, both are taken in as a negative value. 33. In a project comparison tool, even if it compares the project from which a communicative setup differs, a difference is not found. 34. From the "Screen Level Change Flow of Project Manager", the "Screen Editor" is opened. While the "Screen Editor" is in the editable state, the "List" of "Global Cross References" is started. When all the screens that are opened on the "Screen Editor" are closed and the "Overwrite" icon is clicked, an "Application Error" will occur. 35. In "Number of Alarm Occurrences" of "Extended Functions" for "Q-tag Setting": Even an alarm occurs in either a bit log message or a word log message, the number of alarm occurrence is accumulated in both log messages at the same time. 36. The right conversion cannot be performed if a blank line is converted in a text table editor. 37. If "overwrite" operation is carried out to it in case the alarm file (CSV) is re-imported to an alarm editor, alarm message data will disappear. 0-2.GP System Bug Fix List /-- GP SYSTEM V4.35--/ 1. While gAlarm Messageh (right to left scrolling display) is triggered, gAuto Clear Timeh is not cleared to g0h. /-- GP SYSTEM V4.33b--/ 1."Block Display" might operate when "Q Tag Print Settings" is not effective. 2.The "Trigger" might not be done even if the bit of "Qtag Alarm" is "Trigger" state at power supply OFF of GP2000. /-- GP SYSTEM V4.33a--/ 1. When the backlight is OFF or the mode is returning from the standby mode, the Global Interlock function does not operate. /-- GP SYSTEM V4.33--/ 1. When "Global interlock function" is enabled while you are pressing the momentary switch, touching cannot be Off and the touch buzzer does not stop sounding. /-- GP SYSTEM V4.32c--/ 1. When the texts on the part are set on the lamp using Image Font and called on the window, they cannot be displayed. 2. Even when backup is performed for SRAM, blank information for CF card is not updated. /-- GP SYSTEM V4.32b--/ 1. When the CSV data is printed on GP, a large space is created between the date and the time. /-- GP SYSTEM V4.32a--/ 1. Time Base function cannot be used in ST series. /-- GP SYSTEM V4.32--/ The following bugs have been fixed this time. 1. In "GP2301HL" and "GP2301HS", the second one of the 3-point touch menus is not displayed. 2. When the registered external characters are displayed in the situation where "Perpendicular" is selected for GP, they may not be displayed normally. 3. When "Extend settings" for the printer setting is pressed in the offline mode of "GP2500L" and "GP2501L", a system error occurs. /-- GP SYSTEM V4.31--/ 1. When texts are displayed in "K-tag" or "S-tag", symbols other than texts may be displayed. 2. "Brightness" may be disabled in the GP2000 series. 3. In "K-tag" and "Keypad Input Display", the input using the FEP function may not be operated normally. 4. Umlaut characters may not be displayed normally in "CSV Display". 5. The value in the address may not be changed while monitoring the "Device monitor" function. /-- GP SYSTEM V4.30b--/ 1.When the power is supplied to GP2000 Series, Touch Input cannot be enabled. /-- GP SYSTEM V4.30a--/ 1.Decimal point is not displayed in "N-tag" display. /-- GP SYSTEM V4.30--/ 1. In the display of "v tag", if a screen change is performed, a JPEG display may not be displayed correctly. 2. When "#Screen" is being used in a "logic program", a screen change may not operate normally. 3. 32 bit data may not be normally displayed with "N tag" and "E tag". 4. If the usage rate of SRAM is used to about 100%, a "logging function", "trend graph", etc. may not operate. 5. A video display (V tag) may not be displayed at the time of a standby mode return. 6. If "historical" of a "trend graph setting" is operated, a screen will become freeze and a buzzer will sound. 7. As for combined use of a "Time-base function" and "n tag", GP generates a "system error". 8. During "Backlight Burnout" detection, a non-defective component was treated as "Backlight Burnout" for the backlight component characteristics. For this bug, the detection time has been adjusted. 0-3. Pro-Control Bug Fix List /-- Control System V5.13(V4.36)--/ 1. When Provide information is frequently generated under the following conditions, GLC screen switching may be slower. - Provide information is set in Pro-Server. - Trigger is the GLC symbol. 2. Immediately after the GLC starts up, the LED turns red, buzzer sounds intermittently and GLC freezes. /-- Pro-Control V5.10--/ The following bugs have been fixed this time. 1. If a project with default operation is downloaded into new "LT Type H" hardware, although operation at the time of starting is in the state of "Default", it may operate as "Start". 2. When GLC starts up, the image screen freezes for a few seconds. 3. GLC ladder monitor function may freeze depending on the branch circuit configuration. 4. In FlexNetwork 2CH Analog Input/Output unit, data cannot be updated depending on the I/O allocation setting. 5. During the offline mode in "LT TypeB/B+/C", the system error (00A:001D:000) occurs. 0-4. Protocol Bug Fix List 1. MITSUBISHI MELSEC-FX (CPU2) Baud rate has been changed. 2. MITSUBISHI MELSEC-QnA (CPU) When the internal 2-port function is used, communication may be disabled. 3. MITSUBISHI MELSEC-Q (ETHER) When a minus value is entered using a part in Keypad Input Display, "-1" is written. 4. CC-Link Intelligent Device Continuous writing in D-script may cause the slow writing process. 5. SIEMENS S7-300/400 (ETHER) When FGW is used, connection may be disconnected. Even after the reconnection is made, communication is not restored. 6. GE Fanuc Series 90-30/70 SNP When FGW is used, communication may stop. 7. Expansion Modbus When Expansion Modbus and Internal 2-port are used at the same time, communication may not be established. 8. OMRON SYSMAC-CS1 Series The communication error immediately after GP unit starts is not displayed normally. 9. Schneider TSX via UNI-TELWAY Continuous screen touching is suddenly disabled. 10. YASKAWA ELECTRIC CORPORATION MP2000/920 (ETHER) Keeping continuous writing in D-Script slows the writing process. 11. MITSUBISHI MELSEC-FX (CPU2) Baud rate change in the internal 2-port function is supported. 12. Allen Bradley SLC500 Series When the bit-specified address and the word-specified address of the LS device are mixed in D-Script, the word-specified address is changed. 13. OMRON SYSMAC-CS1 (ETHER) Keeping continuous writing in D-Script slows the writing process. 14. SIEMENS S7-300/400 via MPI - During "Duplicate", addresses are not increased normally in gIncremented Addresses for Each Copyh. - In gAddress Block Conversionh, an address is not converted normally. 15. Fuji Electric Corp. MICREX-SX Series When the undefined address ("????") exists, GP units freeze. =========================================================== 1.GP-Pro/PBIII C-Package03 SP2 New Features =========================================================== --------------------------------------------------------------- 1-1. Newly Supported Protocols (1) Mitsubishi Electric Corp. MELSEC FX3UC Series (2) Yokogawa Electric Corp. STARDOM FCN/FCJ Series (3) Fuji Electric Corp. MICREX-SX Series (4) Hitachi S10V Series Ethernet (5) Keyence KV-1000 Series (6) Toshiba Schneider Inverter VF-S9/VF-nC1/VF-S11/VF-A7/VF-P7 Series (7) Ubon UPZ Series (8) Hioki E.E. Corp. Smart Site Series (9) Mitsubishi Electric Corp. MELSEC QUTE CPU Direct connection (10) GE Fanuc Automation Series 90-30/90-70/RX7i Ethernet (11) Toyoda Machine Works PC3JG Series (12) Rockwell SLC500 Series - Addition of devices - Full duplex communication in g1:1 Connectionh is supported. --------------------------------------------------------------- 1-2.PRO/PBIII Upgrade item (1) Time base function is correspondence to a "keypad input display" and a "numeric display". -S5 time-base function of PLC by SIEMENS was corresponded. (2) Model correspondence of ST403 (3) Back light 2 color change function -It is the function of ST403. (4) Global interlock function -It is the function of GP2000 series / ST series. (5) Parts label centering function (6) Function with which the copy area can be specified using the mouse (7) Function switch with Q tag functional correspondence For details, please refer to the GP-PRO/PBIII information manuals. Cautions: Some or all of this data cannot be used and reproduced without notice. ****************** README.TXT End *************************