**************************************************************** GP-PRO/PBIII C-Package03 SP2 **************************************************************** February 28, 2005 Digital Electronics Corporation of Japan Foreword Thank you for purchasing the GP-PRO/PBIII C-Package03 software. GP-PRO/PBIII C-Package03 SP2 is a combined software package of both GP-Pro/PBIII Ver. 7.20 for Windows and Pro-Control Editor Ver. 5.10. The GP-Pro/PBIII Ver. 7.20 for Windows software (hereafter [Pro/PBIII Ver.7.20]) is designed to create screen data for Pro-face GP70, GP77R, GP2000, ST, LT, GLC100, GLC300, and GLC2000 Series programmable operator interfaces. The Pro-Control Editor Ver. 5.10 software (hereafter [Pro-Control Ver.5.10]) is designed to create ladder logic exclusively for LT, GLC100, GLC300, and GLC2000 Series programmable operator interfaces. Designed from the ground up for Windows OS, the GP-PRO/PBIII C-Package03 SP2 software provides easy-to-use, high-performance functionality. ============================================================== Table of contents ============================================================== 0. Bug Fix List 0-1. GP-PRO/PBIII Bug Fix List 0-2. GP System Bug Fix List 0-3. Control System Bug Fix List 1. GP-PRO/PBIII C-Package03 SP2 New Features 1-1. Newly Supported Protocols 1-2. GP-PRO/PBIII New Features ============================================================== 0. Bug Fix List ============================================================== 0-1. GP-PRO/PBIII Bug Fix List /-- PRO/PBIII V7.20 -- / 1. When a value other than 0 is configured for "Decimal Places" in the "Display Format" of Keypad Input Display, and then the "Display Format" is later changed to "Char. String", a decimal point will be displayed. 2. "OMRON SYSMAC-CS1 SERIES" is displayed twice under "Device / PLC Type" while saving using "Save as" function. 3. "An Application error" may occur while setting up "display" of "Data Logging settings." 4. If multiple blocks are used when "Extended Function" and "Block" of "Alarm" are in use, "Alarm messages" other than "Block 1" do not operate correctly. 5. If contents of "Basic Alarm Settings" are all selected, deleted and later pasted, address may be set to 0. 6. If "Screen number" is changed in the "Drawing board", copy of "Color Control" is not carried out. 7. While importing CSV, even if you clear one table in the Text Table Editor, the number of "Characters" of other tables are not cleared. 8. Although "Extended Function" of "Alarm" is not in use, it becomes possible to setup "Multiple", "Accumulate" and "Level" in the "Display Format" of "Q Tag Setting". 9. Software does not operate correctly when "HEX Landscape" of "Popup Keypad Edit" is chosen while screen is open in "Drawing Board", and when the "Drawing Board" is opened from hierarchical display of project manager and icon of "Color Control" in "Edit Tool Bar" is clicked. 10. Even though "Save as default Keypad" is done in "Popup Keypad Edit", it may not be saved. 11. Once updated to C-Package03 SP1 (Ver.7.12), installation of GP37W/GP37W2 cannot be performed. 12. The title of a screen is displayed incorrectly if "Text Landscape" is selected in "Popup Keypad Edit". 13. If "Indirect" is setup in "Alarm Type" of "Alarm Settings" for "Keypad Input Display", "Min. Value" is not displayed in the "List" of "Global Cross Reference". 14. "Invalid Address Error" may occur in "Trend Screen" while preparing transfer. 15. In "Import/Export of Text screen", "GP Font" - "ASCII(Code Page 850)" may not display correctly. 16. Error may display in "Logic Program" transfer part when using "USB Transfer" on GLC. 17. When selecting "GP2000H series", "Clear Area" displays as a different size to that which has been setup in "Popup Keypad Edit". 18. If you export to CSV file in Symbol Editor, the order may not be aligned correctly. 19. In "Text" if you change "Image Font" setup to another font, and then return to the original font, the font style may be changed. 20. If the PC is in "Hyper Threading Mode", screen transfer may not be performed correctly. 21. If "Device/PLC Type" is "Siemens S7-300/400 via MPI", LS backup function is not retained. 22. If 20 or more Windows are registered, then "Print" of "GP Setup" cannot be carried out correctly. 23. In the "specify entering order" of a "keypad input display setting", when the "pop-up keyboard" has been arranged on the square of a screen, the places displayed as the set-up place differ. 24. When GP type was changed into "GP77 series" from "GP70 series", the contents of the message BOX at the time of an "alarm editor" performing "block setup" were unsuitable. 25. When the group-sized object is edited from a "screen data list", there is a case where it stops operating correctly. 26. If "CF card auto save" by the loop of a "data logging setting" is performed, a "header" will be attached to a "CSV file" each time. 27. In a "text table editor", if additional edit is performed, an "application error" will occur. 28. If a "global D script" is chosen and closed in the state where the screen is not opened, to a "screen editor", an "application error" will occur. 29. Operation of other applications becomes slow at the time of screen transmission. 30. In a "project comparison tool", if the "PRW file" which exists at hand is compared with the "PRW file" uploaded from GP, it will be judged as difference in spite of the same data. 31. In a "text table editor ", in case the number of characters exceeds by the half width of one character, if "it imports", the last character may not be displayed correctly. 32. When the CSV file containing the data of the sign of "+" and "-" is taken in, both are taken in as a negative value. 33. In a project comparison tool, even if it compares the project from which a communicative setup differs, a difference is not found. 34. From the "Screen Level Change Flow of Project Manager", the "Screen Editor" is opened. While the "Screen Editor" is in the editable state, the "List" of "Global Cross References" is started. When all the screens that are opened on the "Screen Editor" are closed and the "Overwrite" icon is clicked, an "Application Error" will occur. 35. In "Number of Alarm Occurrences" of "Extended Functions" for "Q-tag Setting": Even an alarm occurs in either a bit log message or a word log message, the number of alarm occurrence is accumulated in both log messages at the same time. 36. The right conversion cannot be performed if a blank line is converted in a text table editor. 37. If "overwrite" operation is carried out to it in case the alarm file (CSV)   is re-imported to an alarm editor, alarm message data will disappear. 0-2.GP System Bug Fix List 1. In the display of "v tag", if a screen change is performed, a JPEG display may not be displayed correctly. 2. When "#Screen" is being used in a "logic program", a screen change may not operate normally. 3. 32 bit data may not be normally displayed with "N tag" and "E tag." 4. If the usage rate of SRAM is used to about 100%, a "logging function", "trend graph", etc. may not operate. 5. A video display (V tag) may not be displayed at the time of a standby mode return. 6. If "historical" of a "trend graph setting" is operated, a screen will become freeze and a buzzer will sound. 7. As for combined use of a "Time-base function" and "n tag", GP generates a "system error." 0-3. Pro-Control Bug Fix List /-- Pro-Control V5.10--/ 1. If a project with default operation is downloaded into new "LT Type H" hardware, although operation at the time of starting is in the state of "Default", it may operate as "Start." =============================================================== 1.GP-Pro/PBIII C-Package03 SP2 New Features =============================================================== --------------------------------------------------------------- 1-1. Newly Supported Protocols (1) Hioki electrical machinery company Smart Site (2) Mitsubishi Electric Corp. MELSEC QUTE CPU Direct connection (3) GE-Fanuc Automation Series90 Ethernet --------------------------------------------------------------- 1-2.PRO/PBIII Upgrade item (1) Time base function is correspondence to a "keypad input display" and a "numeric display". ・S5 time-base function of PLC by SIEMENS was corresponded. (2) Model correspondence of ST403 (3) Back light 2 color change function ・It is the function of ST403. (4) Global interlock function ・It is the function of GP2000 series / ST series. (5) Parts label centering function (6) Function with which the copy area can be specified using the mouse (7) Function switch with Q tag functional correspondence For details, please refer to the GP-PRO/PBIII information manuals. Cautions: Some or all of this data cannot be used and reproduced without notice. ※※※※※※※※※ README.TXT End ※※※※※※※※※※※