**************************************************************** GP-PRO/PBIII C-Package02 **************************************************************** 2003/10/15 Digital Electronics Corporation of Japan Foreword GP-PRO/PBIII C-Package02 is a combined software packageof both GP-Pro/PBIII V6.30 for Windows and Pro-Control Editor V4.30 GP-Pro/PBIII V6.30 for Windows software (listed below as "Pro/PBIII V6.30") is designed to create screen data for Pro- face's GP70, GP77R, GP2000, ST, GLC100, GLC300, and GLC2000 Series programmable operator interfaces.Pro-Control Editor V4.30 software (listed below as Pro-Control V4.30 is designed to create ladder logic exclusively for GLC100, GLC300,and GLC2000 Series programmable operator interfaces. ================================================================ Table of Contents ================================================================ *Regarding Data Transferring via Ethernet 0.Bug Repaired List 0-1. GP-PRO/PBIII Bug Repaired List 0-2. Pro-Control Bug Repaired List 0-3. GP System Program Bug Repaired List 0-4. Protocol Program Bug Repaired List 1.GP-PRO/PBIII C-Package02 New Features 1-1.Newly Supported GPs, GLCs, STs 1-2.Newly Supported Protocols 1-3.GP-PRO/PBIII Upgrade Features 1-4.Pro-Control Upgrade Features ************************************************************** Regarding Data Transferring via Ethernet ************************************************************** 1.First Setup After Purchase via Ethernet Downloading the system program to the GP-2500,GP-2600,GP-2400 or GLC-2400 via Ethernet may not be completed according to the actual network traffic conditions. If this is the case, please reboot the GP and then retry again after confirming the network traffic condition. Else, download this system program via the serial cable. 2.First Setup After Purchase via Ethernet with a Router Downloading the system program to the GP-2500,GP-2600,GP-2400 or GLC-2400 via Ethernet with a router may be aborted after the "2Way-ERROR" message occur. If this the case, please reboot the GP and then retry again. 3.In the case of GP70 or GP77R series that already have either the MTOM-ETHERNET Protocol setup or 2Way Driver(Only GP77R series), only the screen data can be downloaded to the GP via Ethernet. To download the system program, you must use the serial cable. ================================================================ 0.Bug Repaired List ================================================================ ================================================================ 0-1. GP-PRO/PBIII Bug Repaired List /-- V6.30--/ 1.After selecting a protected project, if the user tries to create a new project, an error will be displayed in the Project Mangaer Hierarchical Display. 2.The address where the device code becomes 0x0000 after conversion, by the address conversion is not converted. 3.Even if the symbol is deleted, it is likely to be registered again. 4.The symbol address cannot be used by _ memcpy_EX and _ memset_EX function in D script. 5.If Print is performed with PC which has not installed the printer driver,Print process will not be completed. 6.The word symbol cannot be entered, when the bit symbol having same name is saved in D Script's Address input Dialog. 7.DXF conversion cannot takes place, when the DXF file in which layer(picture layer) name is more than 18 characters. 8.The 2Way Driver will not be deleted, even if the forced transmissin is done to GP2x01,477R,377R with the 2Way Driver not to be sent settting,in which 2Way Driver is already downloded. 9.After changing a system setup by the display machine, the MEM file created by the display machine will not be converted to PRW. 10.If in a folder with the same name upto 8 charcters of *.0pw, *.prw projects are saved and *.prw is compressed using Compress Tool, the new *.0pw file will be overwritten over the old *.0pw. 11.It takes time for automatic setup transfer and to acquire screen list when a large amount of ZRxxxxx.CSV exists in the CF card of the Display Machine. 12.If Special switch is opened again after scrolling Operation Key's left and right Scroll, left and right Scroll will be displayed in opposite direction. 13.If PLC is changed into Siemens S7-300 / 400 via MPI DB device by the address conversion at the time of PLC change, address may not be changed correctly. 14.If D Script's function is printed, forced termination will occur. 15.After editing the Siemens S7-300/400 via MPI project in a Project Mangaer Hierarchical Display, if New project is created without changing the PLC type, the original project's Address will not be displayed properly. 16.When a screen call list straddles two or more pages by printing, forced termination may occur. 17.When the table data which contains the index message of only one new-line code is edited with EXCEL after export, import cannot be done. 18.The capital letter extension of CSV file cannot be imported by the alarm editor. 19.Symbol information used by the alarm cannot be received in V6.20-6.23 20.When the Display range of Trend Graph are set as a negative value, it is not saved properly. 21.All the initial values of a color setup which has initial values other than white at the time of a Monochrome 8Hues becomes black. 22.Even if the character string is set in the conditional expression of the IF condition in D script, it does not become a grammatical error. 23.It takes time to display global cross reference of D script, Global D script and Extended SIO script. 24.The data's of Sound setting,Global D script, Extended SIO script, Logging setting and filing setting cannot be received in a Project Mangaer Hierarchical Display, When the project is transmitted without editing the data after copying by Drag and drop method. 25.When drawing by 256 setting, the blink can be set in the background color of circle and a semicircle graph. 26.The Dot of Block display of the trend graph might not be saved correctly . 27.If the Data transfer function is copied in a Project Mangaer Hierarchical Display, Forced termination occurs. 28.When the system folder is copied by drag & drop method in Project Mangaer Hierarchical Display,Extended SIO script is not copied. 29.The display of the trend graph might be divided into two when the trend graph is moved by ungrouping after placing over the screen. 30.The invalidated symbol might be registered. 31.When 40 Trend Graph parts are set in the whole project, it is impossible to save. 32.It may not operate properly , when parameter 2 of _ CF_delete() function in Extended SIO Script is set other than text. ================================================================ 0-2. Pro-Control Bug Repaired List /-- V4.30--/ 1.The error of I/O cannot be detected by the logic program. 2.When it shifts to programming mode from monitoring mode, save button does not become effective even logic program is changed. 3.If the 12 or more constants are set in logic program, the error will not be displayed properly. 4.The import data set by LT Type-H driver cannot be exported to C-Package. 5.When the Rung selection dialog of a partial export is opened, the range of rung is displayed by 0-0 without fail regardless of the focus position. 6.The contents of a compulsive change of a changed variable in monitoring cannot be uploaded. 7.The present value of a variable cannot be uploaded by bulk package upload. 0-3. GP System Program Bug Repaired List The following list indicates the new system program versions. GP70 series Ver. 1.55d GP675 Ver. 2.35d GLC100 series Ver. 2.57a GP77R, GP377, GLC300 series Ver. 2.69j GP2000, GLC2000 series Ver. 3.58b 1. GP77R, GP377, GLC300 series (Ver. 2.69e -) Ver. 2.69j Changes (1 Indication renewal may stop when a trend graph and alarm    flow are indicated at the same time. (2)When sampling time is more than 32768 seconds, trend graph and data sampling does not operate. 2. GP2000, GLC2000 series (Ver. 3.53b -) Ver. 3.58b Changes (1)When the horizontal/vertical frequency is changed with the same resolution,the display position deviates in the PC display(RGB input display) of the GP2000 VM unit. (2)Indication renewal may stop when a trend graph and alarm flow are indicated at the same time. (3)Graph display (It is painted.) is omitted when a tank graph part is used by the monochrome LCD model of the GP2000 series. (4)A dot of the left end or the right end of the character is not displayed when an image font is used with the transparent by the monochrome LCD model of the GP2000 series. (5)When sampling time is more than 32768 seconds, trend graph and data sampling does not operate. ================================================================ 0-4 Communication Program Bug Repaired List In-Charge of Protocol Team. 1.MultiLink Protocol Object Protocol :Following protocol with which multi link can be connected. Repaierd version Protocol Type : [MITSUBISHI MELSEC-ANA(LINK)] V1.42 : [MITSUBISHI MELSEC-AnN(LINK)] V1.42 : [MITSUBISHI MELSEC-FX2(LINK)] V1.42 : [MITSUBISHI MELSEC-QnA(LINK)] V1.43 : [OMRON SYSMAC-C Series] V1.42 : [OMRON SYSMAC-CV Series] V1.42 : [OMRON SYSMAC-CS1 Series] V1.44 : [SHARP New Satelite JW Series] V1.44 : [YOKOGAWA FACTORY ACE 1:1 Comm] V1.53 : [YOKOGAWA FACTORY ACE 1:n Comm] V1.53 : [YASKAWA GL120/130 Series] V1.43 : [HITACHI HIDIC-H Series] V1.43 : [HITACHI HIDIC-H2 Series] V1.43 : [TOSHIBA PROSEC-T Series] V1.42 : [MATSUSHITA MEWNET-FP Series] V1.45 : [KEYENCE KZ300 Series] V1.42 Content of Change : Watch dog may not operate, when an error occurs by reading, after S tag etc. are started. 2.MEMORY LINK ETHERNET Protocol Repaierd version Protocol Type : [MEMORY LINK ETHERNET Type] V1.67 Content of Change : Display unit will show system error, when it shifts to online having port number of 2Way driver and MtoM Ethernet are same. 3.TOYOTA PC2J/PC3J Protocol Repaierd version Protocol Type : [TOYOTA TOYOPUC-PC2] V1.44 : [TOYOTA TOYOPUC-PC2 1:n Comm ] V1.44 : [TOYOTA TOYOPUC-PC3J] V1.44 : [TOYOTA TOYOPUC-PC3J 1:n Comm ] V1.43 Content of Change : Shifts to off-line screen of Data Write Error, when shifting to online with full system area selected and Data Write Error is set. 4.OMRON SYSMAC C 1:n Protocol Repaierd version Protocol Type : [OMRON SYSMAC C 1:n Comm] V1.41 Content of Change : Shifts to off-line screen of Data Write Error, when shifting to online with full system area selected and Data Write Error is set. 5.MITSUBISHI FX Series Protocol Repaierd version Protocol Type : [MITSUBISHI MELSEC-FX(CPU)] V1.44 Content of Change : Start of communication of GP is slow based on CPU. 6.GE FANUC SNP/SNPX Protocol Repaierd version Protocol Type : [GE FANUC SERIES 90-30/70 SNP] V1.44 : [GE FANUC SERIES 90 SNP-X] V1.43 Content of Change : Bit Invert of Bit Address may not operate properly. 7.AB ControlLogix DF1 Protocol Repaierd version Protocol Type : [AllenBradley ControlLogix DF1] V1.41 Content of Change : Numeric display of 32 bit device flickers. 8.MITSUBISHI MELSEC-Q(ETHER) Protocol Repaierd version Protocol Type : MITSUBISHI MELSEC-Q(ETHER) V1.65 Content of Change : The Screen might not be able to transfer in GP77R Series. ================================================================ 1.GP-PRO/PBIII C-Package02 New Features ================================================================ ---------------------------------------------------------------- 1-1.Newly Supported GPs, GLCs, STs /-- V6.30 --/ (1) GP-2300S (2) ST400/401/402 ---------------------------------------------------------------- 1-2.Newly Supported Protocols /-- V6.30 --/ (1) YASKAWA MP2000/920(ETHER) (2) KEYENCE KZ-10_80R/T SERIES (3) CHINO CONTROLLER (MODBUS) (4) MITSUBISHI MELSEC-FX(CPU2) (5) MITSUBISHI MELSEC-FX 1:N Comm. --------------------------------- 1-3.GP-PRO/PBIII Upgrade Features /-- V6.30 --/ (1)Security function (only for ST series) Using the screen matched to the purposes like the operation, management, and maintenance, etc. becomes possible by using the password function, and it is effective in making the system which considers security. (2)Time Schedule Function(only for ST series) It is easy to execute filing, D script, and the sound function, etc.which operates by the control address at the specified time automatically. (3) Off-line language change function It is not necessary to resend the System,when the menu of off-line is to be changed from Japanese to English. (4)Enhanced function of Duplicating Copy direction where duplicating is done not only for lower right one but also for upper,lower,right and left direction are possible, and the work efficiency will be improved. The width of the address addition when duplicating is done has been enhanced from 255 to 4096. (5)Index Text's centering function It is possible to arrange the character at the center of the index by the index text. (6)1/2Byte Charcteris supported in Chinese,Taiwanese and Korean OS. It is possible to use 1/2Byte Charcter when drawing other than Japanese OS.As a result, it is able to display more information with a medium model. (7) Enhanced Font Size. In addition to the past size 6x10, 8x13, and 13x23 dot's size are added. (Only for alphanumeric character) For detailed information, please refer to your manual. --------------------------------- 1-4.Pro-Control Upgrade Features /-- V4.30 --/ (1)Addition of new instructions 1-1.Trigonmetric Function Instruction(SIN,COS,TAN). 1-2.Radian Conversion instructions(RAD). 1-3.PID operation instruction(PID). (2)Addition of Import/Export Function. 2-1.Variable import/export function from variable list dialog. 2-2.I/O settings import/export function from I/O configuration dialog. (3)Addition of customizing control toolbar function. For detailed information, please refer to your manual. ---------------------------------------------------------------- Note: This document may not be reproduced, either in whole or in part. (C)2003 Digital Electronics Corporation *********************** README.TXT ***************************