HOME
Download Data Inquiry Search Global Sites
Product Line-up Support Company Profile | News | Links | HOME

Error Messages

Among GP-PRO/PBIII drawing commands, the following commands are supported by GP-Web.
- For GP-Web Java Applet - For ASP
- For GP-Web Traffic Center Program - For Easy Connection
- For GP-Web Compiler - For Licence Application
- For GP-Web CGI and GP-Web Traffic Center Program API
GP-Web also displays Pro-Server error massages. If you find such messages, refer to the manual for Pro-Server.


For GP-Web Java Applet
code message
18000 Cannot find Screen File Number XXXX.
18001 Cannot find Screen File XXXX.
18002 Applet cannot be started, because Communication method has not been designated.
18003 XML Analysis error
18004 Primary node name does not exist in browser.
(DEFNODE parameter is not designated in the HTML file.)
18005 Polling start-up failure error
18006 Read Error: Image File
18007 Read Error: Mark File
18008 Cannot start the GP Log Data Display program.
18021 Data transfer has been interrupted (Transmission Time Out)
18022 Cannot link Traffic Center DLL (DirectTCX.DLL)
18024 Pro-Server returned error after attempting device read.
18025 Pro-Server returned error after attempting device write.
18023 Pro-Server returned error after analyzing device name.
18026 Pro-Server returned error after attempting GP reset.
18027 Due to network error, unable to send data
18028 Response communication data packet contains illegal data
18029 Response communication data packet header is illegal
18030 Illegal code in communication data packet :
18031 System Error
18032 User Name data entry has been cancelled. This is because the current user does not have the access privilege.
18033 Cannot find File : XXXX
18034 JAVA Error : XXXX
18035 OS has detected error after calling DirectTCX.DLL : XXXX
18036 Incorrect version of protocol format.

For GP-Web Traffic Center Program Return to Top
code message
19000 Cannot use TCP/IP: Details XXXX XXXX
19001 An error has occurred in TCP/IP socket: Details XXXX XXXX
19002 Received XXXX bytes of data. Data is too large.
19003 System error: Received only XXXX byte in XXXX byte data reception request.
19004 System locked. Program will be shut down
19005 Insufficient memory. Cannot start up the Traffic Center.
19006 Too much data being transmitted. Cannot process all the data.
19007 Pro-Server is not properly installed.
19008 Insufficient memory or memory conflict. Cannot process.
19010 Protocol error. Received illegal data. : XXXX
19011 Received an unsupported (system) code (XXXX). Cannot process.
19012 Received an unsupported command (XXXX). Cannot process.
19013 Duplex routing requested:XXXX
19014 Data syntax error.
19015 Data format version error.
19016 Pro-Server version is too old. Cannot perform processing.
19017 Cannot decode the data?s encryption. Illegal circuit data.
19018 An error has occurred in CGI or the Traffic Center API.
19020 Frame reception has been interrupted.
19021 Receive Node response has stopped during data transmission.
19022 Data communication has been interrupted.
19023 The Traffic Center has not started correctly.
19024 Traffic Center is busy.
19025 The Traffic Center is shut down.
19026 No response from the Traffic Center.
19027 The Traffic Center has already been started.
19028 The Traffic Center has failed to respond within the defined period.
19029 The Traffic Center communication line(s) to external devices is/are disconnected and the Traffic Center cannot respond.
19030 Pro-Server is shut down. Traffic Center cannot continue processing and will be shut down.
19031 An error has occurred during communication with a GP.
(MtoM LAN protocol error)
19032 Traffic Center is currently busy. Your request exceeds the Traffic Center?s usage limit license. Unable to process.
19050 Invalid routing data - cannot be processed.
19051 (XXXX) is not registered as an authorized user.
19052 (XXXX) has no usage right(s).

For GP-Web Compiler Return to Top
code message
20001 Illegal block abort is detected in segmented PRW files.
20002 Code that cannot be analyzed has been detected.
20003 Invalid device address in Project File.Invalid device address in Project File.
20004 Cannot write to XXXX file.
20005 PRW segmented file size is incorrect.
20006 PRW segmented file contents are incorrect.
20007 Cannot access the designated file XXXX.
20008 Cannot process due to insufficient memory.
20009 XXXX file is damaged. Cannot read.
20010 XXXX file is not a project file.
20011 Cannot find the designated PLC protocol table (PLCTBL).Designate the correct Pro-PB folder.
20012 Data Transfer settings are not correct.
20013 Could not convert the Image File.
20014 Could not convert the Alarm Log file data.
20015 No Alarm Log file. Cannot create.
20016 Designate the "SAVE TO" folder. The Web page will be saved in this folder
20017 Illegal/Invalid folder name
20018 No valid Web Compiler found in the Web Compiler folder.
20019 Designate ?SAVE FROM? Project File correctly.
20020 Cannot save setting data. Check the SAVE TO folder.
20021 Selected template file is incorrect. Re-enter.
20022 GPTypes.ID file does not exist or is corrupted.
20023 Designate the Alarm Log data READ TO folder.
20024 Network Project File is not designated. Cannot verify the settings. OK to continue processing?
20025 Node is not designated. Designate the Network Project File and designate that file's node.
20026 Network Project is not designated correctly, or the designated node does not exist in the Network Project. OK to continue processing?
20027 OK to continue processing?
20028 Illegal CSV file name
20029 Network Project File has not been designated.
20030 Node has not been designated. Designate the Network Project File and designate that file?s node.
20031 Name of HTML output file is not designated.
20032 The template file for Alarms is not correct.
20033 The designated Node is illegal/does not exist.
20034 This is not a Network Project File.
20035 The allowed screen size range is from 1 to 1024.
20036 The Timeout value can be from 1 to 3000000.
20037 XXXX is not ready for data transfer. Perform the datatransfer preparation in GP-PRO/PB III for Windows
20038 Cannot find or open XXXX
20039 XXXX is not a Project File. Invalid file format.
20040 Cannot write to the output file.
20041 Error in Project File XXXX.(Error code XXXX)
20042 CF Card folder is not yet created inside the Project File.
20043 Invalid password. Re-enter the password.
20501 Warning!. Unrecognizable substitution mark ($$) in template. XXXX
20502 Warning!. Missing substitution end mark ($$) in template. XXXX
20503 Warning!. No GP Web applet description in template. Browser cannot display the project.
20504 Warning!. Illegal GP Web applet attribute description in template.

For GP-Web CGI and GP-Web Traffic Center Program API
code message
19501 Cannot create the designated file.
19502 Protocol data error. Unreadable words or inconsistent description in the data packet.
19503 A communication error has occurred during data transfer
19504 Parameter error

For ASP Return to Top
code message
21001 UpLoad of latest data has failed
21002 Cannot find the designated folder
21003 Cannot find the designated file
21004 File open error or designated file does not exist
21005 Unable to extract character string
21006 CF CARD file(s) does not exist

For Easy Connection
code message
21201 CSV file read has failed
21202 DirectTCX.dll has not been installed properly
21203 Designated file does not exist, or read in of file failed
21204 It failed in the formation of Folder if there was a mistake in the choice of Folder
21205 Designated folder is not Web Page folder
21206 Select Alarm Item before you push the "UpLoad" button
21207 CF CARD file(s) does not exist

For Licence Application Return to Top
code message
22201 GP-Web Server is not installed properly
22202 Entered data is different from registered KEY CODE
22203 License setup has failed
22204 Same item has been previously registered
22205 It has already registered by the same establishment

  Support

Support Information
Data Download
Technical Information
Manual Data
GP-Web Support
Software User Registration

Web Operation Software
GP-Web
  <-- Back
  <-- Support Top
  <-- Contact Pro-face

Product Line-up

Exhibitions

Industry Trends

Information Journal
Copyright (C) 1996- Digital Electronics Corporation All rights reserved.