| *Please contact your local Pro-face
distributor about MPI, or see the user manual. |
| Functional Specifications |
 |
|
| Item/Model |
ST403-AG41-24V |
| Type |
Monochrome LCD |
| Color |
Monochrome, 2 levels of gray/
Monochrome, 8 levels of gray*1
(Color switching is done via software) |
| Backlight |
LED Backlight*2
|
| Resolution |
320 x 240pixels |
| Display Area |
W76.7mm [3.02in.] x H57.5mm [2.26in.] |
| Brightness Adjustment |
2 levels of adjustment available via touch panel. (Amber only) |
| Contrast Adjustment |
8 levels of adjustment available via touch panel. |
| Language Fonts |
ASCII: (Code page 850) Alphanumeric
(incl. Eur. characters)
Chinese: (GB2312-80 codes) simplified Chinese
fonts
Japanese: ANK 158, Kanji :
6,962 (JIS Standards 1 & 2)(including
607 non-kanji characters)
Korean:
(KSC5601 - 1992 codes) Hangul fonts
Taiwanese:
(Big 5 codes) traditional Chinese fonts |
| Text |
8x8 dots |
40 Char. x 30 rows |
| 8x16 dots |
40 Char. x 15 rows |
| 16x16 dots |
20 Char. x15 rows |
| 32x32 dots |
10 Char. x 7 rows |
| Character |
Character Sizes*4 |
8x8, 8X16, 16X16 and 32X32 dot fonts |
| Font Sizes |
Width can be expanded 1 to 8 times.
Height can be expanded 1/2*5, 1 to 8 times. |
| Memory |
Application |
User screen area 640KB
(Approx.
200 screens at 3.2KB/screen) |
| Data Backup |
96KB User backup memory |
| Uses a rechargeable lithium battery*6 |
| Touch Panel Resolution |
8 x 6 keys/screen (minimum size 40 X 40 dots)
1 or 2 point push - selectable*7 |
| Function keys |
Switches: 6 |
| Interfaces |
Network Interface (X) |
Ethernet (IEEE802.3) 10BACE-T |
| Serial I/F (Y) |
Asynchronous Transmission: RS-232C/RS-422 (Selected by software) Data Length: 7 or 8 bits
Stop Bit: 1 or 2 bits
Parity: None, Odd or Even
Data Transmission Speed: 2,400bps to 115,200bps |
| Tool Connector (TOOL) |
Asynchronous TTL level nonprocedural command I/F <During screen file development>
Used for transferring data to and from the ST application software
and
the ST.
<
During Operation> Used for a variety of devices, including a bar-code reader. |
| *1 |
Depending on the color used, selecting
MONOCHROME 8 HUES may cause the ST unit's screen to flicker and
make it difficult to distinguish shades. Confirm that all colors
display as expected prior to using this mode. |
| *2 |
Among backlight units there may be slight variations in illumination color, however, this does not effect the performance or quality of the ST unit. |
| *3 |
The intended use of red backlight is for special circumstances only. This red backlight has a shorter functional lifespan than the amber backlight. |
| *4 |
The display font will differ depending
on which (language) character, or which
size you select. |
| *5 |
Only available when using "1/2 2 Byte Character" settings via software.
(Only Japanese, Chinese, Taiwanese, and Korean characters.) |
| *6 |
A Lithium battery's lifetime is:
10 years when ST's ambient temperature is 25 oC or less. |
| *7 |
If 2 point push function is selected, the screen areas touched must be separated by at least one grid unit.
Please contact your local Pro-face office for more information. |
|
|
| General Specifications |
 |
|
| Item/Model |
ST403-AG41-24V |
| Rated Voltage |
DC24 V |
| Rated Voltage Range |
DC19.2V to 28.8V |
| Power Consumption |
7W or less |
| Allowable Voltage Drop |
2ms or less |
| In-Rush Current |
50A or less*1 |
| Voltage Endurance |
AC500V 20mA for 1 minute
(between charging and FG terminals) |
| Insulation Resistance |
20Mohm or higher at DC500V
(between
charging and FG terminals) |
Ambient Operating Temperature
(Cabinet Interior) (Panel Face) |
0°C to +50°C*2 |
| Storage Temperature |
-20°C to +60°C |
| Operating Humidity |
10%RH to 90%RH
(Non condensing, wet bulb temperature: 39 °C or less) |
| Storage Humidity |
10%RH to 90%RH
(Non condensing, wet bulb temperature: 39 °C or less) |
| Air Purity (Dust) |
0.1mg/m3 or less (non-conductive levels) |
| Pollution Degree |
Pollution Degree 2 |
| Corrosive Gasses |
Free of corrosive gasses |
Atmospheric Endurance
(ST Operation Altitude) |
800hPa to 1,114hPa (2,000 meters or lower) |
| Vibration Resistance |
IEC61131-2 compliant
When vibration is NOT continuous
10Hz to 57Hz 0.075mm, 57Hz to 150Hz 9.8m/s2
When vibration is continuous 10Hz to 57Hz 0.035mm, 57Hz to 150Hz 4.9m/s2 X, Y, Z directions for 10 times (80min.) |
Noise Immunity
(via noise simulator) |
Noise Voltage: 1,000Vp-p Pulse Duration: 1µs Rise Time: 1ns |
| Electrostatic Discharge Immunity |
6kV (complies with EN 61000-4-2 Level 3) |
Ratings*3
(For front panel of installed unit) |
Equivalent to IP65 (JEM 1030), NEMA#250 Type4X/12 |
| External Dimensions |
W130mm [5.12in] x H104mm [4.09in] x D41mm [1.61in] |
| Weight |
0.4kg (0.88lb) or less |
| Cooling Method |
Natural air circulation |
| *1 |
The FWHM (Full-width, half-maximum) value is approximately 50 us. (When exceeding 25A)) |
| *2 |
The LCD displays of ST may occasionally blur when they are used for hours at over
40oC ambient operating
temperature. This is a temporary phenomenon.
After the temperature returns to normal,
normal display will be restored.
The ST's operation will not be affected
even though the display is blurred. |
| *3 |
The front face of the ST unit, installed
in a solid panel, has been tested using
conditions equivalent to the standards
shown in the specification. Therefore, prior to installing
the ST be sure to confirm the type of conditions
that will be present in the ST's operating
environment. If the installation gasket is
used for a long period of time, or if the
unit and its gasket are removed from the
panel, the original level of the protection cannot
be guaranteed. To maintain the original
protection level, be sure to replace the
installation gasket regularly. |
|
|
| Dimensions |
 |
ST403-AG41-24V |
| |
 |
| |
- All product names used in this page are the registered
trademarks of their respective companies.
- The unit's photos contained in this page may differ
from those of the actual unit.
- All information in this page is valid in Apr, 2005.
- All information contained in this page is subject to
change without notice.
|
 |
Caution: Before operating any of these products, please be sure to read all related manuals thoroughly.
|
|
|
 |
|
 |