| New Features of C-Package03 Service Pack2 |
 |
|
| Time Base Function |
 |
 |
The S5 time base function of SIEMENS's PLC (SIMATIC S5, S7 series),
supported by GP and GLC Series with SP1, can now be used with ST
Series. PROFIBUS protocol is also supported.
(Numeric value display / Set value display supported)
Affected Units: GP2000 Series (except GP-2301HL, GP2301HS, GP-2401HT), GLC2000 Series, ST Series
|
| Part Label Centering Function |
 |
 |
| Add "Centering" button in label settings. When changing characteristics, labels can be centered.
|
|
|
| Global Interlock Function (z tag) |
 |
 |
In the same what of the operation switch used with the GP handy type,
if the bit address is not valid, the operation of the touch panel and function keys
can be invalid.
Affected Units: GP2000 Series, GLC2000 Series, ST Series
|
| Multiple Copy Equal Allocation Function |
 |
 |
The range to copy is designated and the copied objects can be placed at equal intervals.
|
| Special Switch Q tag Function |
 |
 |
| The function "Item selection key for Q tag" is supported in the special switch setting.
|
|
|
| Higher
functionality and more easy to use! |
In addition to GP and GLC Series, GP-PRO/PB III C-Package03 now supports LT Series and ST Series !
|
 |
Supports these new products: LT Color Type, ST Series and GLC2500T !
In addition to "LT Editor", "GP-PRO/PB III C-Package03" can create screens for the Graphic Logic Controller "LT Series" which combines operation, control and display.
|
 |
| Easier
Screen Creation! |
 |
|
| Time Base Function |
 |
 |
Supports S5 time base function, available with PLCs (SIMATIC S5/S7 Series) manufactured by SIEMENS, with an operator interface (Numeric Displays and Keypad Displays).
Applicable Units: GP2000 Series (except GP-2301HL, GP-2301HS, GP-2401HT), GLC2000 Series
|
| ST402's Expansion SIO Switch |
 |
 |
Because of serial I/F switch function, expansion SIO script can be used instead of standard protocol with ST400 and ST401. This function can be used with ST402 (MPI type).
Applicable Units: SimpleTouch (ST402)
|
| CF Write-in Mode Expansion |
 |
 |
Partially changing to write to a CF card can be done with CSV file output function.
Applicable Units: GP2000 Series, GLC2000 Series
|
| Color Setting for Screen Info Text |
 |
 |
Display colors can be selected with a placed part tag's screen info text "address", "tag name" and "ID Number"(8 colors only).
|
| Manual File (PDF) Startup |
 |
 |
The manual file can now be started from the screen editor menu, "HELP(H)" - "MANUAL(M)".
|
Time Schedule |
 |
 |
| Easily set equipment
start up time and periodical tasks! |
Set a bit ON/OFF at a designated time
and day.
- Because weekday and time can be
designated indirectly, the weekdays
and time can be altered on operator
interfaces. |
 |
| *GP/GLC2000 Series
and SimpleTouch only |
| Security Level
Function |
 |
 |
| A conservation screen or an user's
operation range can be limited by levels. |
| Because passwords can be set to
15 levels, the security can be raised
in each screen. |
 |
| - It is secure for equipment placed
outside buildings or unmanned locations.
This is good for limiting access
to screens, such as management or
maintenance screens, that only specified
people can access. |
| *GP/GLC2000 Series
and SimpleTouch only |
| Expanded
Alarm Summary display function
using Q tag |
 |
 |
| The Q tag frequently used for alarm display
is even easier to use. |
| *GP/GLC2000 Series
and SimpleTouch only |
| Improved
Keypad Display function |
 |
 |
| Expanded functions for the keypad displays.
Entering operations on a screen
is improved. |
 |
 |
| Text Screen's
multi-language function |
 |
 |
| Multi-language display can be created
using A and X tags, supported by multi
-language function in the text screen. |
 |
| *GP/GLC2000 Series
and SimpleTouch only |
| Editor operation |
 |
 |
| Improvement of operation makes the editor
easier to use than ever. |
|
 |
| More
Convenient Logic Programming! |
 |
|
| Rungs Making New Line Function |
 |
 |
When a rung becomes too long to fit within a screen, the rung breaks to the next line until the rang stays within the screen.
|
| Function Keys Allocation |
 |
 |
A menu and tool bar can be started up by pressing a function key on the main window.
|
| New Command (Scale Conversion Command) |
 |
 |
Output values can be computed by entering input and output upper and lower limits. (Output value's effective range can be set in a setting screen.)
With this function, the value of variables allocated to an analog unit can be calculated with this command only. In addition, although 4 commands are required for GP-PRO/PB software without SP1, upper limit value/lower limit value can be computed using only this command.
Applicable Units: LT Series, GLC2500T, GLC2300T, GLC2300L, GLC2400T (Rev.2 or later), GLC2600T(Rev.2 or later)
|
| Manual File (PDF) Startup |
 |
 |
| A manual file can be started up from the menu of the Logic Programming Editor, "HELP(H)" - "MANUAL(M)". |
Supports Ladder Monitor |
 |
 |
In addition to GLC2400/2600, GLC2500/2300
and LT series are also supported.
Besides, because the current values/set values
can be altered from not only ladder monitor
but also display screen, the contact point's
ON/OFF and timer/counter's tuning can be
performed even if a computer is not available. |
| Supports Fixed Variables |
 |
 |
For customers who do not know a lot about variable
method, variables can be used as device
addresses similar to PLCs.
The number of variables set in advance
are created automatically, and assigned
to I/O's.
- When creating a logic program, the
variables that are already created,
can be created to match fixed
addresses. |
 |
 |
| *Supported by GLC2000 series
only (except for GLC2400/2600's old
revisions.) |
| Add
New Commands |
 |
 |
| 15 kinds of ladder commands, such
as arithmetic functions, have been
added. This makes developing programs
much easier. |
| *Supported by
GLC2000 series only (except for GLC2400/2600's
old revisions.) |
| More Convenient
to Operate |
 |
 |
| Inserted commands and variables are graphically
displayed, making incorrect ladder
programs easy to avoid. |
 |
|
| |
 |
Caution: Before operating any of these products, please be sure to read all related manuals thoroughly. |
|
|
 |
|
 |