Performance Specifications |
 |
 |
|
| Model |
APL3600-KA |
APL3600-KD |
| Supported OS |
Windows® 2000 /Windows® XP / Windows® XP Embedded |
| CPU |
Intel® CoreTM Duo 2.0GHz / Celeron® M440 1.86GHz |
| Chipset |
Intel® 945GME+ICH7M |
| BIOS |
Phoenix® TrustedCoreTM BIOS |
| Main Memory |
DDR2 SDRAM (PC4200) 512MB / 1GB / 2GB (SO-DIMM x 2 slots) (PC5300) |
| Graphics |
SVGA (800 x 600 pixels) |
| Video Memory |
Max 64MB (UMA Type) |
| Display |
Type |
12.1inch TFT Color LCD |
| Colors |
262,144 Colors |
| Effective Display Area |
W248.0mm[9.76in.] x H186.5mm[7.34in.] |
| Backlight |
CCFL (Replaceable) |
| Touch Panel |
Type |
Resistive Film (Analog) |
| Resolution |
1024 x 1024 |
| Number of Key Switches |
74 |
| Key Switch Type |
Membrane Switch |
| Interfaces |
Serial Interface |
COM1 |
RS-232C
(RS-232C / 422 / 485 changeover, RI / + 5V changeover)
Connector: D-Sub 9-pin Plug |
| COM2 |
RS-232C (RI / +5V changeover)
Connector: D-Sub 9-pin Plug |
| COM3 |
RS-232C
Connector: D-Sub 9-pin Plug |
| COM4 |
RS-232C
Connector: D-Sub 9-pin Plug |
| USB Interface |
USB2.0 Connector: Type A x 5 (Front x 1, Side x 4)
Power Voltage: DC5V 5%, Output Current: 500mA (Max),
Maximum Communication Distance: 5m |
| Ethernet |
LAN 1 |
IEEE802.3u, 10BASE-T / 100BASE-TX / 1000BASE-T Auto change
Connector: Modular Jack (RJ-45) |
| LAN 2 |
IEEE802.3u, 10BASE-T / 100BASE-TX Auto change
Connector: Modular Jack (RJ-45) |
| Disk |
Serial ATA |
Serial ATA Rev.1.0a x 2
2.5 inch HDD Unit |
| IDE I / F |
Master |
CF Card Slot (Type I / II) *1 |
| Slave |
DVD-ROM Drive x 1 |
| Video |
DVI-I Output
Connector: DVI-I 29-pin Socket*2 |
| RAS Interface |
Input (usable as an external reset input): 2 points,
Output: 2 points
Rated Voltage: DC12V
Maximum Rated Current: 100mA
Connector: D-Sub 9-pin Socket x 1 |
| Sound |
Speaker Output Connector: Mini Pin Jack x 1 |
| Expansion Slot |
PCI x 2 / PCI x 4 |
| *1 Can switch between master and slave according to the settings. |
| *2 Only the analog RGB output is supported. |
|
 |
General Specifications |
 |
 |
|
| Model |
APL3600-KA |
APL3600-KD |
| Conforming to Standards |
UL508, CSA22.2, No.142, EN55011 Class A, EN61000-3-2, EN61000-3-3, EN61000-6-2, EN61131-2, EN60950 (AC model only), 47 CFR Part 15 Class A |
| Electrical |
Input Voltage |
AC100 to 240V |
DC24V |
Rated Voltage
(Rated Frequency) |
AC85 to 264V(50/60Hz) |
DC19.2 to 28.8V ( - ) |
| Power Consumption |
145VA or less |
145W or less |
| Allowable Voltage Drop |
Shorter than 1 cycle
(Note that pause occurrences must
be more than 1 second apart.) |
5ms or less |
| Voltage Endurance |
AC1500V 20mA for 1min.
(between charging and FG terminals) |
AC1000V 20mA for 1min.
(between charging and FG terminals) |
| Insulation Resistance |
DC 10MΩ or more at 500V (between charging and FG terminals) |
| Environmental |
Surrounding Air Temperature |
< with HDD> : 5 to 50°C, <without HDD> : 0 to 50°C |
| Ambient Humidity |
10 to 90%RH (No condensation, Wet-bulb temperature: <With HDD> 29°C or lower, <Without HDD> 39°C or lower) |
| Storage Temperature |
-20 to +60°C |
| Storage Humidity |
10 to 90%RH (No condensation) (Wet-bulb temperature : 39°C or lower) |
| Corrosive gas |
Free of corrosive gases |
Noise Immunity
(via noise simulator) |
Noise Voltage: 1500Vp-p,
Pulse width: 50ns,
500ns, 1s,
Rise Time: 1ns |
Noise Voltage: 1000Vp-p,
Pulse Duration:
1s,
Rise Time: 1ns |
| Electrostatic Discharge Immunity |
Contact Discharge Method: 6kV (IEC/EN 61000-4-2 Level 3) |
| Vibration Resistance |
JISB3502, IEC/EN 61131-2 compliant
<with HDD>:10 to 57Hz single-amplitude 0.075mm, 57 to 150Hz constant-accelerated velocity 9.8m/s2, X, Y, Z directions for 10 cycle (100 min.)
<without HDD>:IEC61131-2 compliant, 5 to 9Hz single-amplitude 3.5mm, 9 to 150Hz constant-accelerated velocity 9.8m/s2, X, Y, Z directions for 10 cycle (100 min.) |
| Grounding |
Protective grounding : D type
(Same for FG and SG terminals) |
Functional grounding : D type
(Same for FG and SG terminals) |
| Structural |
Rating |
Equivalent to IP65f (for the panel-installed front area when not using the front-face USB port unit) *3 |
| Cooling Method |
Forced Air Cooling by CPU Fan |
| Weight |
2 slots: 11.0kg (24.2lb) or less (Main unit only)
4 slots: 12.0kg (26.4lb) or less (Main unit only) |
| External Dimensions |
2 slots: W425 [16.73] x H325 [12.80] x D165.5mm [6.52in.]
4 slots: W425 [16.73] x H325 [12.80] x D217.5mm [8.56in.] |
| *3 |
Meets applicabletesting requirements. Operation is not, however, guaranteed in every environment. |
|
 |
Expansion Slot |
 |
 |
|
| |
2slot Model |
4slot Model |
Available Board Size |
| 1st Slot |
PCI Rev.2.3 (5V) |
PCI Rev.2.3 (5V) |
180 [7.09 in.] x 106.68 [4.20 in.] mm |
| 2nd Slot |
| 3rd Slot |
--- |
255 [10.04 in.] x 106.68 [4.20 in.] mm |
| 4th Slot |
| Power Supply *4 |
DC5V:2.0A DC12V:1.0A
DC-12V:0.1A DC3.3V:1.0A |
DC5V:4.0A DC12V:1.0A
DC-12V:0.1A DC3.3V:2.0A |
--- |
| *4 |
Maximum power supply is 40W. |
|
 |
External Dimensions (Units:mm [ in.] ) |
 |
 |
 |
| |
- All product names used in this page are the registered trademarks of their respective companies.
- The unit's photos contained in this page may differ from those of the actual unit.
- All information in this page is valid in May, 2008.
- All information contained in this page is subject to change without notice.
|
 |
Caution: Before operating any of these products, please be sure to read all related manuals thoroughly.
|
|
|
 |
|
 |