Input Specifications
| Rated Voltage | DC24V | |
|---|---|---|
| Maximum Allowable Voltage | DC28.8V | |
| Input Method | Sink / Source Input | |
| Rated Current | 6.5mA (DC24V)
(IN0 , IN2 , IN4 , IN6) , 5mA (DC24V) (Other inputs) |
|
| Input Resistance | Approx. 3.7kΩ
(IN0 , IN2 , IN4 , IN6) , Approx. 4.7kΩ (Other inputs) |
|
| Input Points *1 | 12 | |
| Common Lines | 1 | |
| Common Design | 12 points / 1 common line |
|
| Operation Range | ON Voltage | DC19V or more |
| OFF Voltage | DC5V or less | |
| Input Delay Time *2 | OFF to ON | 0.5 to 20ms *3 |
| ON to OFF | 0.5 to 20ms *3 | |
| Input Signal Display | No LED indicators | |
| Insulation Method | Photocoupler Isolation | |
| External Connection | 22-pin connector (used with Output section) | |
| External Power Supply | For Signal : DC24V | |
- *1
- Input / output No. is different by a combination for exclusive specifications.
- *2
- For the IN0 , IN2 , IN4 , and IN6 , there will be a delay of 5μs depending on the effect of the input delay time. Example : In 0.5 ms cycle sampling , it will be 5μs (ON / OFF) + 0.5 ms (sampling cycle) + 5μs (OFF / ON) =0.51 ms , and there will be at least a 0.51 ms limitation. For the IN1 , IN3 , IN5 , and IN7 to 11 , there will be a delay of 0.5 ms depending on the effect of the input delay time. Example : In 0.5 ms cycle sampling , it will be 0.5 ms (ON / OFF) + 0.5 ms (sampling cycle) + 0.5 ms (OFF / ON) = 1.5 ms , and there will be at least a 1.5 ms limitation.
- *3
- Digital filter can be set at intervals of 0.5 ms.