Home >> Option Line-up
Option Line-up
Software
| Product Name | Model No. | Description | |
|---|---|---|---|
| GP-Pro EX Ver.2.6 | EX-ED-V26 | Screen-creation software | |
| GP-Pro EX Editor License | EX-ED-LICENSE-V26 | GP-Pro EX editor license *1 | |
| Pro-Server EX Ver.1.2 Developer | EX-SDV-V12 | Software that connects a PC to a GP3000 via Ethernet and collects and transmits data *2 | |
| Pro-Server EX Ver.1.2 Developer License | EX-SED-LICENSE | Pro-Server EX developer license *3 | |
| Pro-Server EX Ver.1.2 Runtime License | EX-SRT-LICENSE | Pro-Server EX Runtime license *4 | |
| MES Action License | EX-MES-LICENSE-V10 | License key permitting Pro-Server EX to access a database | |
| GP-Viewer EX | EX-VIEWER-LICENSE | Single license | License allowing a PC to access a GP3000 in remote mode *5 |
| EX-VIEWER-LICENSE-10 | 10 licenses | ||
| EX-VIEWER-LICENSE-30 | 30 licenses | ||
| RPA Client License | EX-RPA | Single license | License to access a PC on the network in remote mode *6 |
| EX-RPA-10 | 10 licenses | ||
| EX-RPA-30 | 30 licenses | ||
| Ladder Monitor License | EX-LADM-MIT-Q02 | License for add-on software that can be monitored by the Ladder Program of Mitsubishi's PLC Q Series | |
| EX-LADM-MIT-A01 | License for add-on software that can be monitored by the Ladder Program of Mitsubishi's PLC A Series (The ladder monitor is supported by the AnA series and the Q series (A mode).) | ||
| EX-LADM-OMR-CJ01 | License for add-on software that can be monitored by the Ladder Program of OMRON's CS/CJ Series | ||
| Video Converter License | EX-MOVCON-LICENSE | License for the file conversion tool required to display video on the GP3000 and PC *5 | |
| WinGP for IPC | EX-WINGP-IPC | Licence for using WinGP on WinGP-compatible IPC. | |
| WinGP for PC/AT | EX-WINGP-PCAT | Licence for using WinGP on PC/AT-compatible PC. | |
| *1 | Purchase this product when installing GP-Pro EX in a second or subsequent PC. One license is required for each PC. |
|---|---|
| *2 | Includes the settings editor and Runtime. |
| *3 | Purchase this product when installing the settings editor and Runtime in a second or subsequent PC. |
| *4 | Purchase this license when installing Runtime only in a second or subsequent PC. One license is required for each PC. |
| *5 | Because the movie converter is included in GP-Pro EX Ver. 2.2, only the license needs to be purchased. |
| *6 | Except for GP3300T/S/L, 3301S/L, and 3200T/A. |
Option Items
| Product Name | Model No. | Description | |||
|---|---|---|---|---|---|
| Cables | USB Transfer Cable (2 m) | CA3-USBCB-01 | USB Cable for transferring data such as screen data (host to host) | ||
| USB Cable (5 m) | FP-US00 | USB Cable for connecting peripheral devices (host to slave) | |||
| USB Front Cable | CA5-USBEXT-01 | Extension cable for attaching to USB port on front panel | |||
| RS-232C Cable (5 m) | CA3-CBL232/5M-01 | COM1 | For COM 1 Cable for RS-232C connection between various hosts and the GP3000 | ||
| RS-422 Cable (5 m) | CA3-CBL422-01 | COM1,2 *7,8,9 | For COM 2 Cable for RS-422 connection between various hosts and the GP3000 | ||
| RS-422 Cable (5 m) | CA3-CBL422/5M-01 | COM1 | For COM 1 Cable for RS-422 connection between various hosts and the GP3000 (Only for connecting devices with a terminal resistance value of 100 ohms) | ||
| Mitsubishi PLC A-Series Connection Cable (5 m) | CA3-CBLA-01 | COM1 | For COM 1 Cable for directly connecting an A Series CPU | ||
| Mitsubishi PLC Q-Series Connection Cable (5 m) | CA3-CBLQ-01 | COM1 | For COM 1 Cable for directly connecting a Q Series CPU | ||
| Mitsubishi PLC Q Series Link Cable (5 m) | CA3-CBLLNKMQ-01 | COM1 | For COM 1 Cable for directly connecting a Q Series Link Unit | ||
| Mitsubishi PLC FX-Series Connection Cable (5 m) | CA3-CBLFX/5M-01 | COM1 | For COM 1 Cable for directly connecting an FX Series CPU | ||
| Mitsubishi PLC FX-Series Connection Cable (1 m) | CA3-CBLFX/1M-01 | COM1 | For COM 1 Cable for directly connecting an FX Series CPU | ||
| Omron PLC SYSMAC Link Cable (5 m) | CA3-CBLSYS-01 | COM1 | For COM 1 Cable for directly connecting a SYSMAC Link Unit | ||
| 2-port Adapter Cable (5 cm) | CA3-MDCB11 | COM1,2 *7,8,9 | For COM 2 Cable for connecting a 2-port adapter to the GP3000 | ||
| Siemens TTY Converter Cable (5 m) |
CA6-CBLTTL/5M-01 | COM1 | For COM 1 Cable for connecting a PLC S5 series to the GP3000 | ||
| MPI Cable (3.5 m) | ST03-A2B-MPI21-PFE | Connects a host controller to the GP for MPI communication | |||
| GP3000-MPI21-PFE | |||||
| Multi-Link Cable | CA3-CBLMLT-01 (5 m) | Connects a host controller to the GP for multi-link(n:1) communication | |||
| RS-232C 9-pin/25-pin Conversion Cable (20 cm) | CA3-CBLCBT232-01 | COM1 | For COM 1 Cable for converting a D-Sub 9-pin plug to a D-Sub 25-pin socket | ||
| RS-422C 9-pin/25-pin Conversion Cable (20 cm) | CA3-CBLCBT422-01 | COM1,2 *7,8,9 | For COM 2 Cable for converting a D-Sub 9-pin socket to a D-Sub 25-pin plug | ||
| GP3000H Connect Cable | GP3000H-CBLH-10M | GP3000H | Hard type/ without connector/ 10m | ||
| GP3000H-CBLHD-10M | GP3000H | Hard type/ with connector/ 10m | |||
| GP3000H-CBLS-*M | GP3000H | Soft type/ without connector/ 3m,5m,10m | "*" is changed with length GP3000H-CBLSD-3M |
||
| GP3000H-CBLSD-*M | GP3000H | Soft type/ with connector/ 3m,5m,10m | |||
| GP3000H Connect Cable for GP2000H Conversion Adapter | GP3000H-CBLSD232-*M | GP3000H | Soft type/ with connector/ 3m,10m | The cable between the GP2000H Series RS-232C Conversion Adapter and the GP3000H, equipped with D-Sub connector. | |
| GP3000H-CBLSD422-*M | GP3000H | Soft type/ with connector/ 3m,10m | The cable between the GP2000H Series RS-422 Conversion Adapter and the GP3000H, equipped with D-Sub connector. | ||
| USB Serial (RS-232C) Adapter Cable (50 cm) | CA6-USB232-01 | COM1 | A Cable converts USB interface to RS-232C | ||
| DVI Cable (5m) | FP-DV01-50 | For outputing image signal from host to GP | |||
| DVI Cable (10m) | FP-DV01-100 | ||||
| DVI-RGB Cable | CA7-CBLCVRGB-01 | For converting DVI-A to RGB | |||
| USB Cable for RGB Input Unit (5m) | CA9-USBAMB/5M-01 | USB cable for RGB Input Unit touch panel operation (Host-Slave: Mini-B) | |||
| RGB Cable (4.5 m) | FP-CV02-45 | For outputing image signal from host to GP | |||
| Adapters | COM Port Conversion Adapter | CA3-ADPCOM-01 | COM1 *11 | For COM 1 Pin conversion adapter for connecting the COM 2-dedicated communication option to the COM 1 port on the GP3000 | |
| Online Adapter | CA4-ADPONL-01 | COM2 | For COM 2 Termination adapter required for communication through the RS-422/485 connection *10 | ||
| Terminal Block Conversion Adapter | CA3-ADPTRM-01 | COM2 | For COM 2 Adapter for converting the COM2 port to the RS-422 terminal block *10,11,12 | ||
| Siemens COM Port Conversion Adapter | CA3-ADPSEI-01 | COM2 | Connects Siemens PLCs to GP3000 *13 | ||
| Mitsubishi PLC A/QnA/FX Series 2-port Adapter II | GP070-MD11 | Interface unit required for simultaneous use of A/QnA/FX Series peripheral devices *14 | |||
| GP3000H Conversion Adapter | AGP3000H-ADPCOM-01 | For interfacing with a RS-232C/RS-422/RS-485 serial interface output (DSUB) | |||
| RS-232C Isolation Unit | CA3-ISO232-01 | COM1 | For COM1 Unit for connecting various hosts and the GP3000 by
insulating <Switching between RS-232c and RS-422 using SW> |
||
| RS-485 Isolation Unit | CA3-ISO485-01 | COM2 | For COM2 Unit for connecting various hosts and the GP3000 by insulating <Switching between RS-422 and RS-485 using SW> |
||
| CF Card Adapter | GP077-CFAD10 | Adapter required for reading the CF card using the PCMCIA slot of a personal computer | |||
| Pin Jack Adapter | GP077-SDAD10 | Adapter for converting the audio output section to the AUX connector to a pin jack | |||
| CF Card | CA3-CFCALL/128MB-01 | 128MB | Compact flash card used for data management such as screen saving and backup of logging data and filing data | ||
| CA3-CFCALL/256MB-01 | 256MB | ||||
| CA3-CFCALL/512MB-01 | 512MB | ||||
| CA6-CFCALL/1GB-01 | 1GB | ||||
| CA8-CFCALL/2GB-01 | 2GB | ||||
| Function Expansion Memory | GP3000-EXDM01 | Memory used for expanding GP-Pro EX alarm and character table functions*15 | |||
| PROFIBUS Slave Unit | CA5-PFSALL/EX-01 | Expansion unit that enables participation of the GP3000 in the PROFIBUS network and communication with the PROFIBUS DP master | |||
| DeviceNet Slave Unit | CA6-DNSALL/EX-01 | Expansion unit that enables participation of the GP3000 in the DeviceNet network and communication with the DeviceNet master | |||
| CC-Link Unit | CA7-CCLALL/EX-01 | Expansion unit that enables participation of the GP3000 in the CC-Link network and communication with the CC-Link master (supports intelligent devices) | |||
| CANopen Slave Unit | CA9-CANALL/EX-01 | Expansion unit that enables participation of the GP3000 in the CANopen network and communication with the CANopen master | |||
| VM Unit *Video images through VM Unit cannot be recorded. |
GP3000-VM01 | Video-Mix Unit (262,000 colors, Video Input x 4ch, DVI Input x 1ch, DVI Output x 1ch, VGA/SVGA/XGA) | |||
| GP2000-VM41 | Video-Mix Unit (32,000 colors, Video Input x 4ch, Analog RGB Input x 1ch, Analog RGB Output x 1ch, VGA/SVGA) | ||||
| DVI Input Unit | GP3000-DVI01 | For inputting DVI to GP <only for 15/12.1/10.4 inch TFT unit> | |||
| RGB Input Unit | GP3000-RGB201 | For displaying analog RGB (2 CH) on the GP3000 | |||
| Panel Cutout Adapter | CA4-ATM10-01 | 10.4-inch TFTscreens | Attachment required for installing a 10.4-inch display unit (TFT) in the mounting hole of GP2500 for a 10.4-inch display unit (TFT) | ||
| CA4-ATM5-01 | 5.7-inch | Attachment required for installing a 5.7-inch display unit in the mounting hole of GP37W2 | |||
| FLEX NETWORK Products *14 | 32-point input Sink/Source type | FN-X32TS41 | I/O unit of 32-point input sink/source sharing type <connects input signals of 24 VDC> | ||
| 16-point input Sink/Source and 16-point transistor output sink type |
FN-XY16SK41 | Input/output combination I/O unit of 16-point input sink/source
and 16-point transistor output Source type <Connects input signals of 24 VDC, 24 VDC for output, and connects devices up to load current 200mA/1 point (1.6A/1 common)> |
|||
| 16-point input Sink/Source and 16-point transistor output source type |
FN-XY16SC41 | Input/output combination I/O unit of 16-point input sink/source
and 16-point transistor output Sink type <Connects input signals of 24 VDC, 24 VDC for output, and connects devices up to load current 200mA/1 point (1.6A/1 common)> |
|||
| 32-point input Sink/Source and 32-point transistor output sink type |
FN-XY32SKS41 | Input/output combination I/O unit of 32-point input sink/source
and 32-point transistor output Sink type <Connects input signals of 24 VDC, 24 VDC for output, and connects devices up to load current 200mA/1 point (1.6A/1 common)> |
|||
| 2-channel Analog/Digital Conversion Unit | FN-AD02AH41 | Converts 2-channel analog signals to digital signals <Resolution: 12 bits> | |||
| 2-channel Digital/Analog Conversion Unit | FN-DA02AH41 | Converts 2-channel 12-bit digital signals to analog signals and outputs the result | |||
| 4-channel Analog/Digital Conversion Unit | FN-AD04AH11 | Converts 4-channel analog signals to digital signals <Resolution: 12 bits> | |||
| 4-channel Digital/Analog Conversion Unit | FN-DA04AH11 | Converts 4-channel 12-bit digital signals to analog signals and outputs the result | |||
| Communication Cable (10 m) ★ | FN-CABLE2010-31-MS | Cables for connecting the GP3000 to the various units | |||
| Communication Cable (50 m) | FN-CABLE2050-31-MS | ||||
| Communication Cable (200 m) | FN-CABLE2200-31-MS | ||||
| CANopen Products | CANopen Slave Unit HTB (Hybrid Terminal Block) | HTB1C0DM9LP | HTB (Hybrid Terminal Block) capable of connecting to the CANopen master. Contains 12 inputs, 6 relay outputs, and 2 digital outputs (source type) | ||
| 8-point input module | EXM-DDI8DT | I/O unit of 8-point input sink/source sharing type | |||
| 16-point input module | EXM-DDI16DT | I/O unit of 16-point input sink/source sharing type | |||
| 8-point relay output module | EXM-DRA8RT | I/O unit of 8-point relay output/2 common type | |||
| 16-point relay output module | EXM-DRA16RT | I/O unit of 16-point relay output/2 common type | |||
| 8-point sink output module | EXM-DDO8UT | I/O unit of 8-point transistor output sink | |||
| 8-point source output module | EXM-DDO8TT | I/O unit of 8-point transistor output source | |||
| 16-point sink output module | EXM-DDO16UK | I/O unit of 16-point transistor output sink | |||
| 16-point source output module | EXM-DDO16TK | I/O unit of 16-point transistor output source | |||
| 4-poinnt input/4-point relay output module | EXM-DMM8DRT | Input/output combination I/O unit of 4-point input sink/source, 4-point relay output, and 1 common type | |||
| 2ch analog input module | EXM-AMI2HT | 2ch analog input type | |||
| Thermocouple/Pt100 input/1 CH analog output module | EXM-ALM3LT | 2ch temperature input/1-point analog output type | |||
| 2ch analog input/1ch analog output module | EXM-AMM3HT | 2ch analog input/1ch analog output type | |||
| 1ch analog output module | EXM-AMO1HT | 1ch analog output type | |||
| Screen Protection Sheet | CA3-DFS15-01 | For 15 inch screen | Sheet for protecting the front of the display unit
from fingerprints, water droplets, powders, dust, and oil mist (5 sheets) |
||
| CA3-DFS12-01 | For 12.1/10.4-inch STN screen | ||||
| CA5-DFS10-01 | For 10.4-inch TFT screen | ||||
| PS400-DF00 | For 7.5-inch screen | ||||
| CA3-DFS6-01 | For 5.7-inch screen | ||||
| CA6-DFS4-01 | For 3.8-inch screen | ||||
| GP3000H-DFS6-01 | GP3000H | ||||
| Wall Mount Adaptor | GP3000H-WMA-01 | GP3000H | Attachment for mounting GP3000H to the wall | ||
| Protective Cover | CA8-ODP10-01 | 10.4-inch (GP-35*0T) |
The installation of the cover is to protect Display from leaking liquid and raise resistant performance against chemical substance (5 sheets) |
||
| CA4 -DCMDL-01 | 5.7-inch (GP-33**T/S/L) |
||||
| Wall Mount Adaptor | GP3000H-WMA-01 | GP3000H | Attachment for mounting GP3000H to the wall | ||
| Touch Pen | CA7-TPPEN/ALL-01 | Touch pens for operating screen(5 units/set) | |||
| Neck Strap | GP2000H-STRAP11 | GP3000H | Strap for hanging GP3000H from neck | ||
| *7 | A COM conversion adapter (CA3 ADPCOM-01) is required for connection of COM1. |
|---|---|
| *8 | At least one online adapter (CA4-ADPONL-01) is required when connecting to COM2 on the GP unit. The isolation unit for COM2 cannot be used. |
| *9 | Use a COM port conversion adapter (CA3-ADPCOM-01) to connect to COM1 on the GP3200T/A. Use a COM port conversion adapter (CA3-ADPCOM-01) to connect to COM2 on the GP-3302B. |
| *10 | COM Port conversion adapter(CA3-ADPCOM-01) is required in connecting to COM1. |
| *11 | At least one online adapter(CA4-ADPONL-01) is required when connecting to COM2. |
| *12 | Use a COM port conversion adapter (CA3-ADPCOM-01) to connect to COM1 on the GP3200T/A. Use a COM port conversion adapter (CA3-ADPCOM-01) to connect to COM2 on the GP-3302B. |
| *13 | Excludes GP3200T/A. For instructions on how to connect, refer to the "GP-Pro EX Device/PLC Connection Manual". |
| *14 | 2port Adapter Cable (CA3-MDCB11) is required. |
| *15 | Screen capacity cannot be expanded. |
| ★ | To purchase this product, please contact our sales staff. |
Maintenance Items
Note: These are replacements for lost or damaged items.
| Product Name | Model No. | Description | |
|---|---|---|---|
| Function Switch Sheet (1sheet) | GP3000H-DUPS-01 | GP3000H | Sheet For replacing the function switch sheet |
| Installation Gasket | CA3-WPG15-01 | for 15 inch | Provides dust and moisture resistance when GP is installed into a solid panel. |
| CA3-WPG12-01 | for 12.1 inch/ 10.4 inch (STN/Mono type) | ||
| CA5-WPG10-01 | for 10.4 inch (TFT type) | ||
| CA5-WPG8-01 | for 7.5 inch | ||
| CA3-WPG6-01 | for 5.7 inch | ||
| ST400-WP01 | for 3.8 inch | ||
| AUX Connector | CA5-AUXCNALL-01 | for 15 inch/ 12.1 inch/ 10.4 inch/ 7.5 inch | AUX connector for GP3000 series required in case an external output is used. |
| Bus Connector Cover | CA3-BUSCVR-01 | Protects the GP unit's rear face connector. (Large size and small size each 1) | |
| USB Cable anti-disconnect holder (RGB Input Unit Side-miniB) | CA9-USBATRGB/MB-01 | 10.4-inch (TFT) or larger | Disconnection prevention clamp for the RGB Input USB Cable |
| USB Cable Clamp (1 port) | CA8-USBATALL-01 | for GP-3310T/3360T | USB Cable clamp for 1 port products to prevent disconnection. (Set of 5 cable clamps) |
| CA5-USBATM-01 | for 5.7 inch (except GP-3310T/3360T) | ||
| USB Cable Clamp (2 ports) | CA5-USBATL-01 | for 15 inch/ 12.1 inch/ 10.4 inch/ 7.5 inch/ 3.8 inch | USB Cable clamp for 2 port products to prevent disconnection. (Set of 5 cable clamps) *16 |
| DC Power Supply Connector | CA5-DCCNM-01 | for 7.5 inch/ 5.7 inch/ 3.8 inch | Connector for attaching power supply to medium-sized units. (Set of 5 connectors) |
| CA5-DCCNL-01 | for 15 inch/ 12.1 inch/ 10.4 inch *17 | Connector for attaching power supply to large-sized units. (Set of 5 connectors) |
|
| Hand Strap | GP3000H-HS-01 | GP3000H | Strap for hanging GP3000H by hand |
| Emergency Stop Switch Guard | GP3000H-EMGD-01 | GP3000H | Guard for preventing to turning on accidentally |
| GP3000H Adapter Gasket | GP3000H-WPGADP-01 | GP3000H | Provides dust and moisture resistance when GP3000H Conversion Adapter is installed into a solid panel. |
| Mounting Bracket | CA3-ATFALL-01 | Wall mounting brackets (4 pcs.) | |
| DIO Connector | CA6-DIOCNALL-01 | Connector attached to the DIO interface. Connects an external I/O device. (Set of 5 connectors) *17 | |
| FLEX NETWORK Connector | CA6-FNCNALL-01 | Connects the FLEX NETWORK single-axis positioning unit and the single-axis teaching loader.(Set of 5 cables) *14 | |
| 64-point DIO Connector | GLC-DIOCN03 | FIN-X632SK41 Connectors (2 pcs.) *17 | |
| DIO Connector for HTB | CA7-HTBCNSET-01 | Connector for HTB1C0DM9LP | |
| MIL Connector (20 pin) for EX module | CA6-EXMCNHE20P-01 | Connector for EX module (5 connectors) | |
| Terminal Connector (11 pin) for EX module | CA6-EXMCNRS11P-01 | ||
| Terminal Connector (10 pin) for EX module | CA6-EXMCNRS10P-01 | ||
| Replacement Backlight | CA3-BLU15-01 | for 15 inch | Replacement backlight for main unit (1 pc.) |
| CA3-BLU12-01 | for 12.1 inch | ||
| CA5-BLU10T-01 | for 10.4 inch (TFT type) *17 | ||
| CA6-BLU10T-02 | for 10.4 inch (TFT type) *17 | ||
| PS501S-BU00 | for 10.4 inch (STN type) | Replacement backlight for main unit (2 pcs.) | |
| *16 | Only 3.8-inch and 7.5-inch models require the dual-point USB Cable Clamp (CA5-USBATL-01). |
|---|---|
| *17 | Backlight specifications vary depending the revision of the GP3000 in use. Refer to the manual for that particular GP3000 revision. |
Last Updated:2009.9.16