| Direct Connection to Field Network |
 |
 |
Profibus |
 |
 |
|
Profibus I/F Unit (GP070-PF11)
| Max.Baud Rate |
12Mbps |
| Max.Node |
64 |
| Max.I/O |
IN:64 Words
OUT:64 Words |
[Units Supported]
SIEMENS
SIMATIC S7-300/400 Series, as well as other Profibus-DP supporting PLCs. |
 |

 |
 |
DeviceNet |
 |
 |
|
Device Net Unit (GP070-DN41)
| Max.Baud Rate |
500Kbps |
| Max.Node |
64 |
| Max.I/O |
IN:127 Words
OUT:127 Words |
|
 |

 |
 |
Interbus |
 |
 |
|
Interbus Unit (GP070-IB41)
| Max.Baud Rate |
500Kbps |
| Max.Node |
512 |
| Max.I/O |
IN:64 Words
OUT:64 Words |
|
 |

 |
 |
CC-Link |
 |
 |
|
CC-Link I/F Unit (GP070-CL11)
| Max.Baud Rate |
10Mbps |
| Max.Node |
64 |
| Max.I/O |
IN:128 Bits
OUT:128 Bits |
[Units Supported]
Mitsubishi Electric Corp. PLC
MELSEC A Series
MELSEC QnA Series |
 |
 |
 |
T-Link |
 |
 |
|
T-Link I/F Unit (GP450-ZB21)
| Max.Baud Rate |
500Kbps |
| Max.Node |
64 |
[Units Supported]
Fuji Electric Co., Ltd.
MICREX-F Series PLCs |
 |
 |
|
 |
Additional Fieldbus Network Units Supported |
 |
 |
|
| Fieldbus |
Module *1 |
GP Model |
| AB Remote I/O |
QPI-ABR-201 |
GP47*/57* series GP470/570,GP477R/577R Series |
| QPJ-ABR-201 |
GP270/370 series |
| AB DH+ |
QPI-ABD-201 |
GP47*/57* series GP470/570,GP477R/577R Series |
| QPJ-ABD-201 |
GP270 series |
| ModbusPlus |
QPI-MDP-201 |
GP47*/57* series GP470/570,GP477R/577R Series |
| QPJ-MDP-201 |
GP270 series |
|
| *1 Manufactured by Total Control Products, Inc. |
| |
- The colors in this page and the PDF catalog may differ
from those of the actual unit.
- Actual user screens may differ from the screens shown here.
- LCD screens may exhibit minute grid-points (light and dark) on the Display Panel surface. Also, "Contouring" - where some parts of the screen are brighter than others, producing a wavelike pattern - may occasionally occur. Both are normal for an LCD display and are not defects.
- All product names used in this page and the PDF catalog
are the registered trademarks of their respective companies.
- All information contained in this page and the PDF
catalog is subject to change without notice.
|
 |
Caution: Before operating any of these products, please be sure to read all related manuals thoroughly.
|
|
|
 |
|
 |