Functional Specifications |
 |
 |
|
| Model |
GLC2500-TC41-200V/GLC2500-TC41-24V |
| Display Type |
TFT Color LCD |
| Display Colors |
256 colors, No blink/64 colors, 3-speed blink (Color switching
is done via software)*1 |
| Backlight |
CCFL (Service life: 50,000 hrs. at 25°C and 24 hrs. operation)
User replaceable. |
| Display Resolution |
640 x 480 pixels |
| Effective Display Area |
W211.2mm [8.31in.] x H158.4mm [6.24in.] |
| Brightness Control |
4 levels of adjustment available via touch panel |
| Language Fonts |
ASCII:(Code page 850) Alphanumeric (including European characters)
Chinese:(GB2312-80 codes) simplified Chinese fonts
Japanese:ANK 158, Kanji: 6962 (JIS Standards 1 and 2)
Korean:(KSC5601-1992 codes) Hangul fonts
Taiwanese:(Big 5 codes) traditional Chinese fonts |
| Text |
8 x 8 dots |
80 Char. x 60 rows |
| 8 x 16 dots |
80 Char. x 30 rows |
| 16 x 16 dots |
40 Char. x 30 rows |
| 32 x 32 dots |
20 Char. x 15 rows |
| Character Sizes*2 |
8 x 8 dot font, 8 x 16 dot font, 16 x 16 dot font, 32 x 32
dot font |
| Font Sizes |
Width: 1~8 times expandable / Height: 1/2*3, 1~8 times expandable |
| Touch Panel Resolution |
32 x 24 keys / screen - 1 or 2 point touch |
| Memory |
Application |
4MB FLASH FEPROM (Approx. 1280 screens at 3.2KB/screen) |
| Data Backup |
256KB SRAM - uses a lithium battery*5 |
Control
Memory*4 |
Program Area |
128KB FLASH EPROM |
| Variable Area |
64KB SRAM - uses a lithium battery*5 |
Serial Interface
(COM1) |
Asynchronous Transmission : RS-232C/RS-422
Data Length: 7 or 8 bits Stop Bit: 1 or 2 bits Parity: None, Odd or Even
Data Transmission Speed: 2,400bps to 115.2kbps (MPI: 187.5kbps)*6 |
Expansion Serial Interface
(COM2) |
Asynchronous Transmission : RS-232C
Data Length : 7 or 8 bits Stop Bit : 1 or 2 bits Parity : None, Odd or Even
Data Transmission Speed : 2,400 bps to 38.4kbps |
| Ethernet Interface |
IEEE802.3 10BASE-T |
| Tool Connector Interface |
Asynchronous TTL level nonprocedural command I/F <During screen file
development>
Used for transferring data to and from the GLC application software and the GLC.
Used for data transfer with the 2-Port feature. <During Logic Program Development>
Used for transferring data to and from the Logic Program Development software
and the GLC. <During RUN Mode>
Used for a variety of devices, including bar-code readers. |
| CF Card Interface |
1 slot (CompactFlash™) |
| Expansion CF Card Interface |
CF Card Front Maintenance Unit Connector |
| Printer Interface |
Compatible with NEC PC-PR201/PL, EPSON ESC/P24-J84(C), HP Laser
Jet PCL 4 command, EPSON PM/Stylus (6-color ink),
EPSON Stylus (4-color) compatible printers*7 |
| External Reset Input I/F |
Remote Reset Input:1 point
Input Voltage: DC24V+/–10%, Input Current: 4mA (TYP), Min. Input Pulse Width:2ms
Operating Voltage: (When ON) Min. DC21.2V, (When OFF) Max. DC3V
Isolation Method: Photo-coupler Isolation |
| Expansion Unit Interface |
Video-Mix Unit |
| Flex Network |
Communication Style |
1: N |
| Connection Format |
Multi Drop Connection |
| Communication Range |
200m/CH at 6Mbps, 100m/CH at 12Mbps |
| Communication Format |
Cyclic Data Transfer, Half-duplex |
| Communication Speed |
6Mbps, 12Mbps |
| Communication I/F |
Differential method, Pulse Transformer Insulation method |
| Error Check |
Format Test, Bit Test, CRC-12 Test |
| Max. Number of Nodes |
63 (1008 I/O points) |
| Sound Output |
| External Speaker Connection (Terminal Block) |
|
Monaural 1CH
Speaker Output 70mW (Rated Load: 8, Frequency: 1kHz) |
Sound Line Out Output 2.7Vp-p (Rated Load: 10k)
Recommended Wire: AWG#28 to #16 |
|
*1 Changing the colors setting to
“256 colors” will disable the blink feature on all screens in your
project. If you wish to use the blink feature, do not change this setting to “256
colors”. *2 The font size varies depending
on the selected language and expansion ratio. *3
Only available when using “1/2 2 Byte Character” settings via software.
(Only Japanese, Chinese, Taiwanese, and Korean characters) *4
128 KB of SRAM is reserved for the Online Editor. *5
A Lithium battery's lifetime is : • 10 years when the battery's ambient
temperature is 40C or less. • 4.1 years when the battery's ambient
temperature is 50C or less. • 1.5 years when the battery's ambient
temperature is 60C or less.
When used for backup : • Approximately 60 days, with a fully charged
battery. • Approximately 6 days, with a half-charged battery. *6
SIEMENS SIMATIC S7-200/300/400 series (MPI port only). Please contact your Pro-face
sales representative for supported models and other details. *7
Printers with only Windows drivers cannot be used. However, certain types of printers
with both Windows® and DOS® drivers can be used. For details, contact
your local GLC distributor. |
|
 |
General Specifications |
 |
 |
|
| Model |
GLC2500-TC41-200V |
| Electrical |
Rated Voltage |
AC100V to AC240V |
DC24V |
| Rated Voltage
Range |
AC85V to AC265V |
DC19.2V to DC28.8V |
| Power Consumption |
50VA or less (ACIN100V)
85VA or less (ACIN240V) |
50W or less |
| Allowable Voltage
Drop |
20ms or less |
10ms or less |
| Voltage Endurance |
AC1500V 20mA for 1 minute (between charging
and FG terminals) |
AC1000V 20mA for 1 minute (between charging
and FG terminals) |
| Insulation Resistance |
or higher at DC500V (between charging
and FG terminals) |
| Environmental |
Ambient Operating
Temperature
|
0C to +50C |
| Storage Temperature |
-20C to +60C |
| Operating Humidity |
10%RH to 90%RH (Non-condensing,
wet bulb temperature:39C or less) |
| Storage Humidity |
10%RH to 90%RH (Non-condensing,
wet bulb temperature:39C or less) |
| Vibration Resistance |
| IEC61131-2 (JIS B 3501) compliant |
|
When vibration is NOT continuous: 10Hz to 57Hz
0.075mm, 57Hz to 150Hz 9.8m/s2
When vibration is continuous: 10Hz to 57Hz 0.035mm, 57Hz to 150Hz 4.9m/s2 X, Y,
Z directions for 10 times (80min.) |
|
| Noise Immunity
(via noise simulator) |
Noise Voltage: 1500Vp-p, Pulse Duration:1
s Arise Time: 1ns |
| Electrostatic Discharge
Immunity |
Contact Discharge Method 6kV (complies
with IEC 61000-4-2 Level 3) |
| Air Purity (Dust) |
0.1mg/m3 or less (non-conductive
levels) |
| Atmospheric Endurance |
800hPa to 1,114hPa (2,000 meters
or lower) |
| Corrosive Gasses |
Free of corrosive gases |
| Structural |
Grounding |
100 or less, or your country’s
applicable standard*1 |
| Ratings |
Equivalent to IP65f (JEM1030)*2,
and NEMA#250 Type4 X/12 (limited to the front face after installation in a panel) |
| Certifications |
EN55011 Class A, EN61000-3-2, EN61000-3-3,
EN61000-6-2, EN60950, UL 60950, UL1604 |
EN55011 Class A, EN61000-6-2,
UL 508, UL 1604 |
| Certifications |
W317mm [12.48in.] x H243mm [9.57in.]
x D58mm [2.28in.] (main unit only) |
| Weight |
3.5kg (7.72lb) or less (main unit
only) |
| Cooling Method |
Natural air circulation |
*1 Grounding requirements
differ from country to country. Be sure to confirm your work environment requirements
prior to installation. For more information, please contact your GLC distributor.
*2 The degree of protection provided by these products
is equivalent to IP65f, however their performance cannot be guaranteed for every
environment. Be sure to confirm your work environment requirements prior to installation. |
|
 |
Dimensions (Units:mm [ in.] ) |
|
 |
|
 |
 |
Caution: Before operating any of these products, please be sure to read all related manuals thoroughly. |
|
|
 |
|
 |