Functional Specifications |
 |
 |
|
| Item |
FP790-TC21 |
| Display |
Type |
14.1" TFT color
LCD |
| Colors |
262,144 colors |
| Resolution |
1,024(H) x 768(V)
pixels |
Mode
(selected with a switch) |
640 x 480 (VGA)
720 x 400 (US Text)
800 x 600 (SVGA)
1,024 x 768 (XGA) |
| Display
Area (mm) |
285.7 W x 214.3 H |
Brightness
/
Contrast control |
On Screen Menu via
Touch Panel |
| Backlight |
CCFL
Lifetime of 30,000 hours or longer
(time required for backlight brightness dim 50% of original level - at
25 °C and 24 hr. operation) |
| Rubber
Gasket |
Analog Resistance
Film |
| Touch
Panel |
Resolution :1,024 x 1,024 |
| Interface |
Analog RGB input, RS-232C input,
PS / 2 input and output (both mouse) |
|
 |
General Specifications |
 |
 |
|
| Item |
FP790-TC21 |
| Electrical |
Input
Voltage |
AC 100V to 240V
50 / 60Hz |
| Rated
Voltage |
AC 85V to 265V |
| Allowable
Voltage Drop |
20ms or less |
| Power
Consumption |
65VA or less |
| Voltage
Endurance |
Voltage Endurance
AC1500V, 20mA for up to 1 minute
(between charging and FG terminals) |
| Insulation
Resistance |
Insulation Resistance
10Mohm or more at DC500V
(between charging and FG terminals) |
| Environmental |
Ambient
Operating
Temperature
(Panel interior and Panel face) |
0°C to 40°C
*1 |
| Storage
Temperature |
-10°C to 60°C |
| Ambient Humidity |
30%RH to 85%RH (non-condensing) |
| Vibration
Resistance |
19.6m/s2 at 10Hz to 25Hz
(x,y,z directions : 30minutes each) |
Noise Immunity
(via noise simulator) |
Noise Voltage: 1500 Vp-p
Pulse Duration: 50n,100n,1µs. Rise Time:
1ns |
| Atmosphere |
Free of corrosive gases |
| Certifications |
CE Marking (EN55011 Class A,
EN61000-6-2, EN60950) |
| Structural |
Grounding |
100ohm or less, or your country's
applicable standard |
| Ratings |
Equivalent to IP65f (front face
only with the Front Hatch closed) *2 |
| Cooling Method |
Natural air circulation |
| Weight |
Approx. 6.5kg [16.5Ib] |
Dimensions
(W x H x D) |
405 mm [16.2 in] x 350 mm [14.0
in.] x 74 mm [3.0 in.] |
|
| *1 |
Operating temperature reflects the panel external
(FP unit front face) and panel internal temperatures. |
| *2 |
Testing equivalent to IP65f conditions has been performed,
however, performance
cannot be guaranteed for every type of environment.
Using the FP with the front panel's cover open will reduce the level of protection. |
 |
Dimensions (Units:mm
[ in.] ) |
 |
 |
|
 |
 |
Caution: Before operating any of these products, please be sure to read all related manuals thoroughly. |
|
|
 |
|
 |