 Meanings of the front LED status and indications


The following table shows meanings of front LED status and indications in each IPC product.

Series Models Front LED
Status Indication
PL-3000 Series (with a monitor) APL3600/3700/3900 Click here

Click here

PL-x930 Series PL6930/6931/7930/7931 Click here
PL-x920 Series PL6920/6921/7920/7921 Click here
PL-5910 Series PL5910/5911 Click here
PL-5900 Series PL5900/5901 Click here
PS-3000A Series (with a monitor) PS-3450A/PS-3451A/
PS-3710A/PS-3711A
Click here
PS-3700A/PS-3701A Click here
PS-3650A/PS-3651A Click here
FP-2000 and FP-3000 Series FP3500/3600/3650/3700/3710/
2500/2600/2650
Click here Click here
PS-3600G PS-3600G Click here Click here
 
List of the front LED status (in the PL3000 series with a monitor)

 
List of the front LED status (in the PLx930 series)

 
List of the front LED status (in the PLx920 series)

 
List of the front LED status (in the PL5910 series)

 
List of the front LED status (in the PL5900 series)

 
List of the front LED status (PS-3450A / PS-3451A / PS-3710A / PS-3711A)

 
List of the front LED status (PS-3700A / PS-3701A)

 
List of the front LED status (PS-3650A / PS-3651A)

 
List of the front LED status (in the FP2000 and FP3000 series)

 
List of the front LED status (PS-3600G)

 
Meanings of the front LED status and indications (in the PL and PS series)

LED Status Indication

Software Off
System Stop

The same status as after completion of Windows shutdown process.
It is not in abnormal status even though the system is not working.

System Monitor Error
RAS Error
Some kind of a RAD error occurred
(In the case that the setting of LED error action is ON in the property of System Monitor)
Open System Monitor by clicking the icon on a task bar to check where the error occurs.
Touch Panel Self-Test Error In the case that there is no error occurring in System Monitor, since a user cannot cope with the error on their own, please ask for repair of the IPC unit.
Software Mirror Disk Error
Hardware Mirror Disk Error

(Only in the models supporting Mirror Disk)
An error is detected in the configuration for mirroring.
Please take action on the error after confirming the configuration at the moment.

Software Mirroring Utility (PL-SM900) User Manual
- Monitoring via the RAS System Monitor

Mirror Disk Unit (PL-MD200) Installation Guide
- HDD Installation

Backlight Error An error on backlight is detected.
Consider a replacement of the backlight.
System in operation with battery
System in standby with battery
PS-365xA
The status shows that a battery is working, in the case that a unit is equipped with a Battery Unit as an option.
 
Meanings of the front LED status and indications (in the FP2000 and FP3000 series)

LED Status Indication
Orange lit

Normal operation in a FP unit, but a display signal from a connected device is not detected.

Green/Red blinking
Orange blinking
An error on backlight is detected.
Consider a replacement of the backlight.
 
Meanings of the front LED status and indications (PS-3600G)

LED Status Indication
Lit by the RAS feature

(In the case that the setting of LED error action is ON in the property of System Monitor)
Open System Monitor by clicking the icon on a task bar to check where the error occurs.

PS-3600G Series User Manual
- RAS Control
- Processing Functions

System Error An error is detected in start-up data. Consider performing recovery of CF card.

PS-3600G Series User Manual
- Recovery
 
Back to page top Return to the previous page