Errors displayed in the conversion management information file
Error No. |
Error Message |
Solution |
501 |
Internal variable mapped to I/O terminal |
An internal variable is mapped to the I/O terminal. Change the variable type to either input or output. |
502 |
Input variable mapped to output terminal |
The variable is marked as an input, but it is mapped to an output terminal. Change the variable type to output. |
503 |
Output variable mapped to input terminal |
The variable is marked as an output, but it is mapped to an input terminal. Change the variable type to input. |
504 |
Bit valiable mapped to integr terminal. |
The variable is marked as discrete, but it is mapped to an integer terminal. Change the variable type to integer. |
505 |
Integr valiable mapped to bit terminal. |
The variable is marked as an integer, but it is mapped to a discrete terminal. Change the variable type to discrete. |
506 |
Variable type not supported by I/O driver. |
This error occurs when the driver does not recognize the controller variable. |
507 |
A variable is not mapped to the terminal. |
This error occurs when no variable is assigned to a terminal. |
Other errors
Error Message |
Cause |
Solution |
The selected Device/PLC is unavailable for conversion. Change the Device/PLC before conversion. |
A device/PLC type which is not supported by GP-Pro EX is selected. |
In GP-PRO/PBIII for Windows, change the device/PLC to a device/PLC supported by GP-Pro EX and then execute Project Converter again. For device/PLCs supported by GP-Pro EX, refer to 2.1.3 Devices before and after Conversion.
|
Cannot read the source Device/PLC file. |
Cannot recognize the convert-from device/PLC type. |
In GP-PRO/PBIII for Windows, change the device/PLC to a device/PLC supported by GP-Pro EX and then execute Project Converter again. For device/PLCs supported by GP-Pro EX, refer to 2.1.3 Devices before and after Conversion.
|
The selected model is unavailable for conversion. Change the model. |
A display type which is not supported by GP-Pro EX is selected. |
In GP-PRO/PBIII for Windows, change the display type to a GP type supported by GP-Pro EX and then execute Project Converter again. For supported models, refer to 2.1.2 Model Names Before and After Conversion.
|
Cannot read the model information file. |
Cannot recognize the convert-from model. |
In GP-PRO/PBIII for Windows, change the display type to a display type supported by GP-Pro EX and then execute Project Converter again. For supported models, refer to 2.1.2 Model Names before and after Conversion.
|
Cannot read AGPCnv.cfg file |
Failed to load GP-Pro EX's AGPCnv.cfg file. |
Install GP-Pro EX again. |
Cannot read the prw file. |
Failed to read a GP-PRO/PBIII for Windows file (.PRW). Microsoft Windows access authority may be set to the GP-PRO/PBIII for Windows file (.PRW). |
Check the file properties in Explorer and check the access authority settings. |
Cannot access the parts file. |
Failed to read a GP-PRO/PBIII for Windows Part file (.PDB or .BPD). Microsoft Windows access authority may be set to the GP-PRO/PBIII for Windows Part file (.PDB or .BPD). |
Check the file properties in Explorer and check the access authority settings. |
Invalid extention. |
An incorrect extension is designated in Project Converter's [Convert To]. |
Input a correct extension (.prx). |