Condition Number (Group Number)
Designate the condition number. The setting range is from 0 to 1023. Assign each condition its own unique number.
Condition Name (Group Name)
Set a condition name up to 32 characters long (16 double-byte characters). When transferring data from device/PLC to CF Card/USB Storage, the CSV file condition name is the name defined here.
Destination
Destination Word Address
The specified address functions as the destination address (or as the source address when transferring from the device/PLC to the CF Card/USB storage device). An internal device address can also be set.
Number of Data Items
Set the number of data transfer units from 1 to 10000.
Display Format
Select the display format of the transfer data from [Dec], [Hex], or [Float].
Bit Length |
Display Format |
Sign +/- |
Data range |
16 bit |
Dec |
Cleared |
0 to 65535 |
Selected |
-32768 to 32767 | ||
Hex |
- |
0 to FFFF(h) | |
32 bit |
Dec |
Cleared |
0 to 4294967295 |
Selected |
-2147483648 to 2147483647 | ||
Hex |
- |
0 to FFFFFFFF(h) | |
Float |
- |
17 integral digits, 16 decimal places |
For operations if data contains out-of-range values, refer to the following. 25.10.1 How to Transfer CSV Data, Values Transfer to Device/PLC
If [Float] is selected, [Bit Length] is fixed to [32 Bits].
Sign +/-
Set to allow negative numbers. This is available only when the [Display Format] is [Dec].
Bit Length
Choose the bit length from [16 Bit] or [32 Bit].
File Number
Start/End
Set the file range to register as a single condition with file numbers. The setting range is from 0 to 65535. All the files from [Start] to [End] become part of the same group.
Please do not set the same file number to multiple conditions. If file numbers repeat in several conditions, the files are transferred according to the condition with the smallest number.