30.7.11.4 Object 2102h: Analog Input Lower Limit

This object stores the minimum value of the user-defined measurement range (corresponding sub index value of object 2101h = 1).

Properties

Object properties:

Sub index

Description

Data Type

Default

Access

PDO mapping

Backup

0

Sub index number (analog input number)

UNSIGNED8

24

ro (read only)

×

1

Minimum measured value of CH1

INTEGER16

0

rw (read-write)

×

...

 

 

 

18

Minimum measured value of the last channel

INTEGER16

0

rw (read-write)

×